21 research outputs found

    Effectiveness of prophylactic implantation of cardioverter-defibrillators without cardiac resynchronization therapy in patients with ischaemic or non-ischaemic heart disease: a systematic review and meta-analysis

    Get PDF
    Aims: Much controversy exists concerning the efficacy of primary prophylactic implantable cardioverter-defibrillators (ICDs) in patients with low ejection fraction due to coronary artery disease (CAD) or dilated cardiomyopathy (DCM). This is also related to the bias created by function improving interventions added to ICD therapy, e.g. resynchronization therapy. The aim was to investigate the efficacy of ICD-only therapy in primary prevention in patients with CAD or DCM.Methods and results: Public domain databases, MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials, were searched from 1980 to 2009 for randomized clinical trials of ICD vs. conventional therapy. Two investigators independently abstracted the data. Pooled estimates were calculated using both fixed-effects and random-effects models. Eight trials were included in the final analysis (5343 patients). Implantable cardioverter-defibrillators significantly reduced the arrhythmic mortality [relative risk (RR): 0.40; 95 confidence interval (CI): 0.27-0.67] and all-cause mortality (RR: 0.73; 95 CI: 0.64-0.82). Regardless of aetiology of heart disease, ICD benefit was similar for CAD (RR: 0.67; 95 CI: 0.51-0.88) vs. DCM (RR: 0.74; 95 CI: 0.59-0.93).Conclusions: The results of this meta-analysis provide strong evidence for the beneficial effect of ICD-only therapy on the survival of patients with ischaemic or non-ischaemic heart disease, with a left ventricular ejection fraction ā‰¤35, if they are 40 days from myocardial infarction and ā‰„3 months from a coronary revascularization procedure

    Recurrence of ventricular arrhythmias in ischaemic secondary prevention implantable cardioverter defibrillator recipients: long-term follow-up of the Leiden out-of-hospital cardiac arrest study (LOHCAT)

    Get PDF
    Aims to assess the long-term rate of mortality and the recurrence of potentially life-threatening ventricular arrhythmias in secondary prevention implantable cardioverter defibrillator (ICD) patients and to construct a model for baseline risk stratification.Methods and resultsSince 1996, all patients with ischaemic heart disease, receiving ICD therapy for secondary prevention of sudden death, were included in the current study. Patients were evaluated at implantation and during long-term follow-up. A total of 456 patients were included in the analysis and followed for 54 Ā± 35 months. During follow-up, 100 (22) patients died and ICD therapy was noted in 216 (47) patients, of which 138 (30) for fast, potentially life-threatening ventricular arrhythmia. Multivariate analysis revealed a history of atrial fibrillation or flutter (AF), ventricular tachycardia as presenting arrhythmia, and wide QRS and poor left ventricular ejection fraction as independent predictors of life-threatening ventricular arrhythmias. The strongest predictor was AF with a hazard ratio of 2.1 (95 confidence interval 1.3-3.2). On the basis of the available clinical data, it was not possible to identify a group which exhibited no risk on recurrence of potentially life-threatening ventricular arrhythmias.ConclusionIschaemic secondary prevention ICD recipients exhibit a high recurrence rate of potentially life-threatening ventricular arrhythmias. Factors that increase risk can be identified but, even with these factors, it was not possible to distinguish a recurrence-free group

    Morphology discrimination in implantable cardioverter-defibrillators: Consistency of template match percentage during atrial tachyarrhythmias at different heart rates

    No full text
    Background: Morphology discrimination (MD) in implantable cardioverter-defibrillators (ICDs) is based on the comparison of the ventricular electrogram during tachycardia with a stored reference template obtained during baseline rhythm. However, the effect of heart rate on the template match percentage during supraventricular tachyarrhythmias (SVT) is not known. The purpose of this study was to evaluate the performance of the template match percentage during SVT at different heart rates. Methods and results: Stored electrograms of 868 tachyarrhythmias from 88 patients with a dual-chamber ICD (St Jude Medical, USA) were analysed by the investigators. The effect of heart rate on template match percentage was estimated by regression analysis. For performance measures, data were corrected for multiple episodes in a patient by using the generalized estimating equation method. The mean template match percentage was 86.6 Ā± 22.2% (median 100%) for SVT episodes. No significant differences in template match percentage between fast [ventricular cycle length (CL) 300-350 ms] and slow (ventricular CL >400 ms) SVTs were observed (85.4 Ā± 27.0 vs. 87.1 Ā± 19.7%). Using nominal settings, MD alone provided sensitivity and specificity of 70.2% and 89.4% overall, respectively. Morphology discrimination in conjunction with rate branch analysis, sudden onset, and stability yielded sensitivity and specificity of 98.5% and 91.2%, respectively. Conclusion: Morphology discrimination has a consistently high template match percentage during SVTs, which is independent of ventricular CL. The consistent high match percentage results in high specificity for arrhythmia discrimination