9 research outputs found

    Portable Apparatus for Electrochemical Sensing of Ethylene

    Get PDF
    A small, lightweight, portable apparatus based on an electrochemical sensing principle has been developed for monitoring low concentrations of ethylene in air. Ethylene has long been known to be produced by plants and to stimulate the growth and other aspects of the development of plants (including, notably, ripening of fruits and vegetables), even at concentrations as low as tens of parts per billion (ppb). The effects are magnified in plant-growth and -storage chambers wherein ethylene can accumulate. There is increasing recognition in agriculture and related industries that it is desirable to monitor and control ethylene concentrations in order to optimize the growth, storage, and ripening of plant products. Hence, there are numerous potential uses for the present apparatus in conjunction with equipment for controlling ethylene concentrations. The ethylene sensor is of a thick-film type with a design optimized for a low detection limit. The sensor includes a noble metal sensing electrode on a chip and a hydrated solid-electrolyte membrane that is held in contact with the chip. Also located on the sensor chip are a counter electrode and a reference electrode. The sensing electrode is held at a fixed potential versus the reference electrode. Detection takes place at active-triple-point areas where the sensing electrode, electrolyte, and sample gas meet. These areas are formed by cutting openings in the electrolyte membrane. The electrode current generated from electrochemical oxidation of ethylene at the active triple points is proportional to the concentration of ethylene. An additional film of the solid-electrolyte membrane material is deposited on the sensing electrode to increase the effective triple-point areas and thereby enhance the detection signal. The sensor chip is placed in a holder that is part of a polycarbonate housing. When fully assembled, the housing holds the solid-electrolyte membrane in contact with the chip (see figure). The housing includes a water reservoir for keeping the solid-electrolyte membrane hydrated. The housing also includes flow channels for circulating a sample stream of air over the chip: ethylene is brought to the sensing surface predominately by convection in this sample stream. The sample stream is generated by a built-in sampling pump. The forced circulation of sample air contributes to the attainment of a low detection limit

    Safety and Efficacy of a Dapivirine Vaginal Ring for HIV Prevention in Women.

    Get PDF
    BACKGROUND: The incidence of human immunodeficiency virus (HIV) infection remains high among women in sub-Saharan Africa. We evaluated the safety and efficacy of extended use of a vaginal ring containing dapivirine for the prevention of HIV infection in 1959 healthy, sexually active women, 18 to 45 years of age, from seven communities in South Africa and Uganda. METHODS: In this randomized, double-blind, placebo-controlled, phase 3 trial, we randomly assigned participants in a 2:1 ratio to receive vaginal rings containing either 25 mg of dapivirine or placebo. Participants inserted the rings themselves every 4 weeks for up to 24 months. The primary efficacy end point was the rate of HIV type 1 (HIV-1) seroconversion. RESULTS: A total of 77 participants in the dapivirine group underwent HIV-1 seroconversion during 1888 person-years of follow-up (4.1 seroconversions per 100 person-years), as compared with 56 in the placebo group who underwent HIV-1 seroconversion during 917 person-years of follow-up (6.1 seroconversions per 100 person-years). The incidence of HIV-1 infection was 31% lower in the dapivirine group than in the placebo group (hazard ratio, 0.69; 95% confidence interval [CI], 0.49 to 0.99; P=0.04). There was no significant difference in efficacy of the dapivirine ring among women older than 21 years of age (hazard ratio for infection, 0.63; 95% CI, 0.41 to 0.97) and those 21 years of age or younger (hazard ratio, 0.85; 95% CI, 0.45 to 1.60; P=0.43 for treatment-by-age interaction). Among participants with HIV-1 infection, nonnucleoside reverse-transcriptase inhibitor resistance mutations were detected in 14 of 77 participants in the dapivirine group (18.2%) and in 9 of 56 (16.1%) in the placebo group. Serious adverse events occurred more often in the dapivirine group (in 38 participants [2.9%]) than in the placebo group (in 6 [0.9%]). However, no clear pattern was identified. CONCLUSIONS: Among women in sub-Saharan Africa, the dapivirine ring was not associated with any safety concerns and was associated with a rate of acquisition of HIV-1 infection that was lower than the rate with placebo. (Funded by the International Partnership for Microbicides; ClinicalTrials.gov number, NCT01539226 .)

    Persufflation (gaseous oxygen perfusion) as a method of heart preservation

    Get PDF
    Persufflation (PSF; gaseous oxygen perfusion) is an organ preservation technique with a potential for use in donor heart preservation. Improved heart preservation with PSF may improve outcomes by maintaining cardiac tissue quality in the setting of longer cold ischemia times and possibly increasing the number of donor hearts available for allotransplant. Published data suggest that PSF is able to extend the cold storage times for porcine hearts up to 14 hours without compromising viability and function, and has been shown to resuscitate porcine hearts following donation after cardiac death. This review summarizes key published work on heart PSF, including prospective implications and future directions for PSF in heart transplantation. We emphasize the potential impact of extending preservation times and expanding donor selection criteria in heart allotransplant. Additionally, the key issues that need to be addressed before PSF were to become a widely utilized preservation strategy prior to clinical heart transplantation are summarized and discussed.This item is part of the UA Faculty Publications collection. For more information this item or other items in the UA Campus Repository, contact the University of Arizona Libraries at [email protected]

    Safety, adherence, and HIV-1 seroconversion among women using the dapivirine vaginal ring (DREAM) : an open-label, extension study

    No full text
    BACKGROUND : The Ring Study, a phase 3 trial in 1959 sexually active women (randomised 2:1), showed a favourable safety profile and a 31% HIV-1 infection risk reduction for a vaginal ring containing 25 mg of dapivirine, compared with a placebo ring. We report here the DREAM study, which aimed to evaluate safety, adherence, and HIV-1 incidence in those using the dapivirine vaginal ring (DVR) in open-label use. METHODS : The DREAM study is an open-label extension of The Ring Study, done at five research centres in South Africa and one research centre in Uganda. Former participants from The Ring Study, who remained HIV-negative and who did not discontinue the study due to an adverse event or safety concern that was considered to be related to the investigational product, were eligible. Women who were pregnant, planning to become pregnant, or breastfeeding at screening for DREAM were excluded. All participants received the DVR for insertion at the enrolment visit. Participants attended a 1-month follow-up visit and could either proceed with visits once every 3 months or attend monthly visits up to month 3 and then continue with visits once every 3 months. At each visit, HIV testing and safety evaluations were done, and residual dapivirine measured in used rings (approximately 4 mg is released from the DVR over 28 days of consistent use). HIV-1 incidence was compared descriptively with the simulated incidence rate obtained from bootstrap sampling of participants in the placebo group of The Ring Study, matched for research centre, age, and presence of sexually transmitted infections at enrolment. This study is registered with ClinicalTrials.gov, NCT02862171. FINDINGS : Between July 12, 2016, and Jan 11, 2019, 1034 former participants from The Ring Study were screened, 941 were enrolled and 848 completed the trial. 616 (65·5%) of 941 participants reported treatment-emergent adverse events. Of these, six (0·6%) had events considered to be treatment-related. No treatment-related serious adverse events were reported. Measurements of monthly ring residual amounts in participants enrolled in both trials showed consistently lower mean values in DREAM than in The Ring Study. Arithmetic mean ring residual amounts of participants in The Ring Study DVR group who enrolled in DREAM were 0·25 mg lower (95% CI 0·03–0·47; p=0·027) than the mean ring residual amounts of these participants in The Ring Study. 18 (1·9%) HIV-1 infections were confirmed during DVR use, resulting in an incidence of 1·8 (95% CI 1·1–2·6) per 100 person-years, 62% lower than the simulated placebo rate. INTERPRETATION : Although efficacy estimation is limited by the absence of a placebo group, the observed low HIV-1 incidence and improved adherence observed in DREAM support the hypothesis that increased efficacy due to improved adherence occurs when women know the demonstrated safety and efficacy of the DVR. The feasibility of a visit schedule of once every 3 months was shown, indicating that the DVR can be used in a real-world situation in usual clinical practice.The Ministry of Foreign Affairs (MFA) Denmark, Flanders MFA, Irish Aid, Dutch MFA, UK Aid from the UK Government’s Foreign, Commonwealth and Development Office, and the US President’s Emergency Plan for AIDS Relief through the US Agency for International Development.https://www.thelancet.com/journals/lanhiv/homeam2022Family Medicin

    Persufflation (gaseous oxygen perfusion) as a method of heart preservation

    Get PDF
    Persufflation (PSF; gaseous oxygen perfusion) is an organ preservation technique with a potential for use in donor heart preservation. Improved heart preservation with PSF may improve outcomes by maintaining cardiac tissue quality in the setting of longer cold ischemia times and possibly increasing the number of donor hearts available for allotransplant. Published data suggests that PSF is able to extend the cold storage times for porcine hearts up to 14 hours without compromising viability and function, and has been shown to resuscitate porcine hearts following donation after cardiac death. This review summarizes key published work on heart PSF, including prospective implications and future directions for PSF in heart transplantation. We emphasize the potential impact of extending preservation times and expanding donor selection criteria in heart allotransplant. Additionally, the key issues that need to be addressed before PSF were to become a widely utilized preservation strategy prior to clinical heart transplantation are summarized and discussed
    corecore