150 research outputs found

    Chemical laboratories 4.0: A two-stage machine learning system for predicting the arrival of samples

    Get PDF
    This paper presents a two-stage Machine Learning (ML) model to predict the arrival time of In-Process Control (IPC) samples at the quality testing laboratories of a chemical company. The model was developed using three iterations of the CRoss-Industry Standard Process for Data Mining (CRISP-DM) methodology, each focusing on a different regression approach. To reduce the ML analyst effort, an Automated Machine Learning (AutoML) was adopted during the modeling stage of CRISP-DM. The AutoML was set to select the best among six distinct state-of-the-art regression algorithms. Using recent real-world data, the three main regression approaches were compared, showing that the proposed two-stage ML model is competitive and provides interesting predictions to support the laboratory management decisions (e.g., preparation of testing instruments). In particular, the proposed method can accurately predict 70% of the examples under a tolerance of 4 time units.This work has been supported by FCT – Funda ̧c ̃ao para a Ciˆencia e Tecnologiawithin the R&D Units Project Scope: UIDB/00319/2020. The authors also wishto thank the chemical company staff involved with this project for providing thedata and also the valuable domain feedback

    Arthroscopic evaluation of the ACL double bundle structure

    Get PDF
    In order to describe the arthroscopic presence of the double bundle structure and to evaluate the value of different portals in knee arthroscopy, we assessed the AM and PL bundle anatomy. We prospectively examined the knees of 60 patients undergoing arthroscopic surgery for pathology unrelated to the ACL. Arthroscopy was performed in a two portal technique using an anterolateral (ALP) and an anteromedial (AMP) portal. With the arthroscope in the ALP, we could distinguish an AM and PL bundle in 28%. Switching the arthroscope to the AMP, differentiation of the bundles was possible in 67%. In all remaining cases visualization of the PL bundle was possible after retraction of the AM bundle. Use of AMP increased visualization of the PL bundle. It seems reasonable to perform arthroscopy for ACL reconstruction with the arthroscope in the AMP and to establish an additional medial working portal to increase the visualization of the femoral ACL insertion sites for optimal femoral tunnel placement

    Innovation for an inclusive future

    Get PDF
    This workshop will focus on setting the agenda for research, practice and policy in support of inclusive design for third generation computer-based products. The next generation of technology represents an unprecedented opportunity to improve the quality of life for groups of users who have previously faced exclusion, such as those with impairments and older citizens. At the same time it risks creating a greater digital divide and further exclusion. How we approach design for this new generation will determine whether or not the third wave will provide positive advances towards an inclusive digital world. We therefore need to put forward both a rationale for inclusive design and provide pointers towards technical development and design practice in support of inclusion. It is our belief that there is not only a strong moral case for design for inclusion but also significant commercial incentive, which may be key to persuading influential players to focus on inclusion. Therefore one of our key objectives is to describe and promote the advantages of designing ‘in from the edges’ of the user population rather than designing for a notional ‘average’ user

    Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Accurately measuring <it>in-vivo</it> motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, <it>in-vivo</it> motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion.</p> <p>Methods</p> <p>To assess the accuracy of this technique, we implanted tantalum beads into the femur and patella of three cadaveric knee specimens and then recorded dynamic biplane radiographic images while manually flexing and extending the specimen. The position of the femur and patella were measured from the biplane images using both the model-based tracking system and a validated dynamic radiostereometric analysis (RSA) technique. Model-based tracking was compared to dynamic RSA by computing measures of bias, precision, and overall dynamic accuracy of four clinically-relevant kinematic parameters (patellar shift, flexion, tilt, and rotation).</p> <p>Results</p> <p>The model-based tracking technique results were in excellent agreement with the RSA technique. Overall dynamic accuracy indicated errors of less than 0.395 mm for patellar shift, 0.875° for flexion, 0.863° for tilt, and 0.877° for rotation.</p> <p>Conclusion</p> <p>This model-based tracking technique is a non-invasive method for accurately measuring dynamic PF joint motion under <it>in-vivo</it> conditions. The technique is sufficiently accurate in measuring clinically relevant changes in PF joint motion following conservative or surgical treatment.</p

    Factors that influence the intra-articular rupture pattern of the ACL graft following single-bundle reconstruction

    Get PDF
    The number of revision anterior cruciate ligament (ACL) surgeries performed annually continues to rise. The purpose of this study was to determine the most common rupture pattern in ACL revision cases after previous single-bundle reconstruction. The second aim was to determine the relationship between rupture pattern and patient-specific factors (age, gender, time between the initial ACL reconstruction and re-injury, and etiology/mechanism of failure) and surgical factors (graft type, tunnel angle). This was a cohort study of 60 patients that underwent revision ACL surgery after previous single-bundle ACL reconstruction. Three sports medicine-trained orthopedic surgeons reviewed the arthroscopic videos and determined the rupture pattern of the grafts. The rupture pattern was then correlated to the above-mentioned factors. The inter-observer agreement had a kappa of 0.7. The most common rupture pattern after previous single-bundle ACL reconstruction is elongation of the graft. This is different from the native ACL, which displays more proximal ruptures. With the use of autograft tissue and after a longer period of time, the rupture pattern in revision surgery is more similar to that of the native ACL. The most common rupture pattern after previous single-bundle reconstruction was elongation of the graft. Factors that influenced the rupture pattern were months between ACL reconstruction and re-injury and graft type. Cohort study, Level I

    Genome-wide identification and phenotypic characterization of seizure-associated copy number variations in 741,075 individuals

    Get PDF
    Copy number variants (CNV) are established risk factors for neurodevelopmental disorders with seizures or epilepsy. With the hypothesis that seizure disorders share genetic risk factors, we pooled CNV data from 10,590 individuals with seizure disorders, 16,109 individuals with clinically validated epilepsy, and 492,324 population controls and identified 25 genome-wide significant loci, 22 of which are novel for seizure disorders, such as deletions at 1p36.33, 1q44, 2p21-p16.3, 3q29, 8p23.3-p23.2, 9p24.3, 10q26.3, 15q11.2, 15q12- q13.1, 16p12.2, 17q21.31, duplications at 2q13, 9q34.3, 16p13.3, 17q12, 19p13.3, 20q13.33, and reciprocal CNVs at 16p11.2, and 22q11.21. Using genetic data from additional 248,751 individuals with 23 neuropsychiatric phenotypes, we explored the pleiotropy of these 25 loci. Finally, in a subset of individuals with epilepsy and detailed clinical data available, we performed phenome-wide association analyses between individual CNVs and clinical annotations categorized through the Human Phenotype Ontology (HPO). For six CNVs, we identified 19 significant associations with specific HPO terms and generated, for all CNVs, phenotype signatures across 17 clinical categories relevant for epileptologists. This is the most comprehensive investigation of CNVs in epilepsy and related seizure disorders, with potential implications for clinical practice
    corecore