92 research outputs found

    Short-term outcomes of mirogabalin in patients with peripheral neuropathic pain: a retrospective study

    Get PDF
    Background Mirogabalin, which is approved for the treatment of peripheral neuropathic pain in Japan, is a ligand for the α2δ subunit of voltage-gated calcium channels. Both pregabalin and mirogabalin act as nonselective ligands at the α2δ-1 and α2δ-2 subunits. Mirogabalin has a unique binding profile and long duration of action. Pregabalin has been reported to produce intolerable adverse effects in some patients. This study investigated outcomes associated with mirogabalin administration in patients with peripheral neuropathic pain who ceased treatment with pregabalin. Methods We retrospectively assessed peripheral neuropathic pain using the neuropathic pain screening questionnaire (NeP score) in 187 patients (58 men, 129 women) who were treated with mirogabalin. All patients had switched from pregabalin to mirogabalin due to lack of efficacy or adverse events. Differences in the treatment course (i.e., numeric rating scale (NRS) scores) were compared using one-way analysis of variance with Bonferroni post hoc tests. Results The mean age of the patients was 72.3 years (range, 30–94 years), and the mean duration of disease was 37 months (range, 3–252 months). After treatment with mirogabalin for 1 week, NRS scores significantly decreased compared with baseline and continued to decrease over time. After 8 weeks, NRS scores improved by ≥ 30% from baseline in 113 patients (69.3%). Twenty-four patients (12.8%) stopped mirogabalin treatment due to adverse events. Somnolence (26.7%), dizziness (12.3%), edema (5.9%), and weight gain (0.5%) were noted as adverse events of mirogabalin. Conclusions The results of this investigation indicate that mirogabalin is safe and effective for reducing peripheral neuropathic pain

    EOS789, a broad-spectrum inhibitor of phosphate transport, is safe with an indication of efficacy in a phase 1b randomized crossover trial in hemodialysis patients

    Get PDF
    The treatment of hyperphosphatemia remains challenging in patients receiving hemodialysis. This phase 1b study assessed safety and efficacy of EOS789, a novel pan-inhibitor of phosphate transport (NaPi-2b, PiT-1, PiT-2) on intestinal phosphate absorption in patients receiving intermittent hemodialysis therapy. Two cross-over, randomized order studies of identical design (ten patients each) compared daily EOS789 50 mg to placebo with meals and daily EOS789 100 mg vs EOS789 100 mg plus 1600 mg sevelamer with meals. Patients ate a controlled diet of 900 mg phosphate daily for two weeks and began EOS789 on day four. On day ten, a phosphate absorption testing protocol was performed during the intradialytic period. Intestinal fractional phosphate absorption was determined by kinetic modeling of serum data following oral and intravenous doses of 33Phosphate ( 33P). The results demonstrated no study drug related serious adverse events. Fractional phosphate absorption was 0.53 (95% confidence interval: 0.39,0.67) for placebo vs. 0.49 (0.35,0.63) for 50 mg EOS789; and 0.40 (0.29,0.50) for 100 mg EOS789 vs. 0.36 (0.26,0.47) for 100 mg EOS789 plus 1600 mg sevelamer (all not significantly different). The fractional phosphate absorption trended lower in six patients who completed both studies with EOS789 100 mg compared with placebo. Thus, in this phase 1b study, EOS789 was safe and well tolerated. Importantly, the use of 33P as a sensitive and direct measure of intestinal phosphate absorption allows specific testing of drug efficacy. The effectiveness of EOS789 needs to be evaluated in future phase 2 and phase 3 studies

    New CTI Correction Method for the Spaced-Row Charge Injection of the Suzaku X-Ray Imaging Spectrometer

    Full text link
    The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the CTI, we have applied a spaced-row charge injection (SCI) technique to the XIS in orbit; by injecting charges into CCD rows periodically, the CTI is actively decreased. The CTI in the SCI mode depends on the distance between a signal charge and a preceding injected row, and the pulse height shows periodic positional variations. Using in-flight data of onboard calibration sources and of the strong iron line from the Perseus cluster of galaxies, we studied the variation in detail. We developed a new method to correct the variation. By applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008 is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated CCD.Comment: 7 pages, 14 figure

    The ASTRO-H X-ray Observatory

    Full text link
    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.Comment: 22 pages, 17 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray

    The Quiescent Intracluster Medium in the Core of the Perseus Cluster

    Get PDF
    Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injection by the central supermassive black hole and the use of hydrostatic equilibrium for the determination of cluster masses. X-rays from the core of the Perseus cluster are emitted by the 50 million K diffuse hot plasma filling its gravitational potential well. The Active Galactic Nucleus of the central galaxy NGC1275 is pumping jetted energy into the surrounding intracluster medium, creating buoyant bubbles filled with relativistic plasma. These likely induce motions in the intracluster medium and heat the inner gas preventing runaway radiative cooling; a process known as Active Galactic Nucleus Feedback. Here we report on Hitomi X-ray observations of the Perseus cluster core, which reveal a remarkably quiescent atmosphere where the gas has a line-of-sight velocity dispersion of 164+/-10 km/s in a region 30-60 kpc from the central nucleus. A gradient in the line-of-sight velocity of 150+/-70 km/s is found across the 60 kpc image of the cluster core. Turbulent pressure support in the gas is 4% or less of the thermodynamic pressure, with large scale shear at most doubling that estimate. We infer that total cluster masses determined from hydrostatic equilibrium in the central regions need little correction for turbulent pressure.Comment: 31 pages, 11 Figs, published in Nature July

    EURECA: European-Japanese microcalorimeter array

    Get PDF
    The EURECA project aims to demonstrate technological readiness of a micro-calorimeter array for application in future X-ray astronomy missions, like Constellation-X, EDGE, and XEUS. The prototype instrument consists of a 5 × 5 pixel array of TES-based micro-calorimeters read out by two SQUID-amplifier channels using frequency-domain-multiplexing (FDM) with digital base-band feedback. The detector array is cooled by a cryogen-free cryostat consisting of a pulse tube cooler and a two stage ADR. Initial tests of the system at the PTB beam line of the BESSY synchrotron showed stable performance and an X-ray energy resolution of 1.5 eV at 250 eV for read-out of one TES-pixel only. Next step is deployment of FDM to read-out the full array. Full performance demonstration is expected end 2008.This work was financially supported by the Dutch Organization for Scientific Research (NWO).Peer Reviewe

    The Japanese Clinical Practice Guidelines for Management of Sepsis and Septic Shock 2016 (J-SSCG 2016)

    Get PDF
    Background and purposeThe Japanese Clinical Practice Guidelines for Management of Sepsis and Septic Shock 2016 (J-SSCG 2016), a Japanese-specific set of clinical practice guidelines for sepsis and septic shock created jointly by the Japanese Society of Intensive Care Medicine and the Japanese Association for Acute Medicine, was first released in February 2017 and published in the Journal of JSICM, [2017; Volume 24 (supplement 2)] https://doi.org/10.3918/jsicm.24S0001 and Journal of Japanese Association for Acute Medicine [2017; Volume 28, (supplement 1)] http://onlinelibrary.wiley.com/doi/10.1002/jja2.2017.28.issue-S1/issuetoc.This abridged English edition of the J-SSCG 2016 was produced with permission from the Japanese Association of Acute Medicine and the Japanese Society for Intensive Care Medicine.MethodsMembers of the Japanese Society of Intensive Care Medicine and the Japanese Association for Acute Medicine were selected and organized into 19 committee members and 52 working group members. The guidelines were prepared in accordance with the Medical Information Network Distribution Service (Minds) creation procedures. The Academic Guidelines Promotion Team was organized to oversee and provide academic support to the respective activities allocated to each Guideline Creation Team. To improve quality assurance and workflow transparency, a mutual peer review system was established, and discussions within each team were open to the public. Public comments were collected once after the initial formulation of a clinical question (CQ) and twice during the review of the final draft. Recommendations were determined to have been adopted after obtaining support from a two-thirds (> 66.6%) majority vote of each of the 19 committee members.ResultsA total of 87 CQs were selected among 19 clinical areas, including pediatric topics and several other important areas not covered in the first edition of the Japanese guidelines (J-SSCG 2012). The approval rate obtained through committee voting, in addition to ratings of the strengths of the recommendation, and its supporting evidence were also added to each recommendation statement. We conducted meta-analyses for 29 CQs. Thirty-seven CQs contained recommendations in the form of an expert consensus due to insufficient evidence. No recommendations were provided for five CQs.ConclusionsBased on the evidence gathered, we were able to formulate Japanese-specific clinical practice guidelines that are tailored to the Japanese context in a highly transparent manner. These guidelines can easily be used not only by specialists, but also by non-specialists, general clinicians, nurses, pharmacists, clinical engineers, and other healthcare professionals

    Cooling system for the soft X-ray spectrometer onboard Astro-H

    Get PDF
    金沢大学理工研究域数物科学系The Soft X-ray Spectrometer (SXS) is a cryogenic high resolution X-ray spectrometer onboard the X-ray astronomy satellite Astro-H which will be launched in 2014. The detector array is cooled down to 50 mK using an adiabatic demagnetization refrigerator (ADR). The cooling chain from the room temperature to the ADR heat-sink is composed of superfluid liquid He, a Joule-Thomson cryocooler, and double-stage Stirling cryocoolers. It is designed to keep 30 l of liquid He for more than 5 years in the normal case, and longer than 3 years even if one of the cryocoolers fails. Cryogen-free operation is also possible in the normal case. It is fully redundant from the room temperature to the ADR heat-sink. © 2010 Elsevier Ltd
    corecore