87 research outputs found

    Femoral revision knee Arthroplasty with Metaphyseal sleeves: the use of a stem is not mandatory of a structural point of view

    Get PDF
    Purpose Metaphyseal sleeves are an option for patients with severe metaphyseal bony defects requiring TKA revision. Although sleeves are usually used with stems, little is known about the exact contribution/need of the stem for the initial sleeve-bone interface stability, particularly in the femur, if the intramedullary canal is deformed or bowed. It is hypothesised that diaphyseal-stem addition increases the sleeve-femur interface stability and the strain-shielding effect on the metaphyseal femur relatively to the stemless condition. Material and methods Synthetic-femur was used to measure cortex strain behaviour and implant cortex micromotions for three techniques: only femoral-component, stemless-sleeve and stemmed-sleeve. Paired t-tests were performed to evaluate the statistical significance of the difference between mean principal strains and implant-cortex micromotions. Finite-element models were developed to assess the cancellous-bone strain behaviour and sleeve-bone interface micromotions; these models were validated against the measurements. Results Cortex strains are reduced significantly (p<0.05) in 83% of strain gauges on stemmed-sleeve, which compares with 33% in stemless condition. Both techniques presented a cancellous bone strain reduction of 50% at the distal region and an increase of nearly four times at the sleeve proximal region relative to the model only with the femoral component. Both techniques presented sleeve-bone micromotions amplitude below 50-150μm, suitable for bone ingrowth. Conclusions The use of a supplemental diaphyseal-stem potentiates the risk of cortex bone resorption compared with the stemless-sleeve condition; however, the stem is not vital for increasing the initial sleeve-bone stability and has a minor effect on the cancellous-bone strain behaviour. Of a purely structural point view, appears that the use of a diaphyseal-femoral-stem with the metaphyseal sleeve is not mandatory in the revision TKA which is particularly relevant in cases where the use of stems is impracticable.publishe

    Comparative indoor and outdoor stability measurements of polymer based solar cells

    Get PDF
    We report comparative indoor and outdoor stability testing of organic solar cells based on a blend between a donor-acceptor polyfluorene copolymer and a fullerene derivative. The outdoor testing was conducted for a period over 12,000 hours in Sheffield, England, with a Ts80 lifetime determined in excess of 10,000 hours (420 days). Indoor lifetime testing was performed on solar cells using a solar simulator under a constant irradiance of 1000 W/m(2) for more than 650 hours. We show that under the conditions explored here, device degradation under the two sets of conditions is approximately dependent on the absorbed optical energy dose

    Daptomycin antimicrobial activity tested against methicillin-resistant staphylococci and vancomycin-resistant enterococci isolated in European medical centers (2005)

    Get PDF
    BACKGROUND: Daptomycin is a cyclic lipopeptide with potent activity and broad spectrum against Gram-positive bacteria currently used for the treatment of complicated skin and skin structure infections and bacteremia, including right sided endocarditis. We evaluated the in vitro activity of this compound and selected comparator agents tested against clinical strains of staphylococci and enterococci collected in European medical centers in 2005. METHODS: A total of 4,640 strains from 23 medical centers located in 10 European countries, Turkey and Israel (SENTRY Program platform) were tested for susceptibility by reference broth microdilution methods according to Clinical and Laboratory Standards Institute guidelines and interpretative criteria. Mueller-Hinton broth was supplemented to 50 mg/L Ca(++ )for testing daptomycin. Results for oxacillin (methicillin)-resistant staphylococci and vancomycin-resistant enterococci were analyzed separately. RESULTS: Oxacillin resistance rates among Staphylococcus aureus varied from 2.1% in Sweden to 42.5% in the United Kingdom (UK) and 54.7% in Ireland (29.1% overall), while vancomycin resistance rates varied from 0.0% in France, Sweden and Switzerland to 66.7% in the UK and 71.4% in Ireland among Enterococcus faecium (17.9% overall). All S. aureus strains were inhibited at daptomycin MIC of 1 mg/L (MIC(50/90), 0.25/0.5 mg/L; 100.0% susceptible) and only one coagulase-negative staphylococci strain (0.1%) showed an elevated (>1 mg/L) daptomycin MIC value (4 mg/L). Among E. faecalis (MIC(50/90), 0.5/1 mg/L; 100% susceptible) the highest daptomycin MIC value was 2 mg/L; while among E. faecium (MIC(50/90), 2/4 mg/L; 100% susceptible) the highest MIC result was 4 mg/L. CONCLUSION: Daptomycin showed excellent in vitro activity against staphylococci and enterococci collected in European medical centers in 2005 and resistance to oxacillin, vancomycin or quinupristin/dalfopristin did not compromise its activity overall against these pathogens. Based on these results and those of previous publications, daptomycin appears to be an excellent therapeutic option for serious infections caused by oxacillin-resistant staphylococci and vancomycin-resistant enterococci in Europe

    Patient specific cutting blocks are currently of no proven value

    No full text

    Patient-specific instruments in total knee arthroplasty

    No full text
    • …
    corecore