2,022 research outputs found

    Geometrical edge barriers and magnetization in superconducting strips with slits

    Full text link
    We theoretically investigate the magnetic-field and current distributions for coplanar superconducting strips with slits in an applied magnetic field H_a. We consider ideal strips with no bulk pinning and calculate the hysteretic behavior of the magnetic moment m_y as a function of H_a due solely to geometrical edge barriers. We find that the m_y-H_a curves are strongly affected by the slits. In an ascending field, the m_y-H_a curves exhibit kink or peak structures, because the slits prevent penetration of magnetic flux. In a descending field, m_y becomes positive, because magnetic flux is trapped in the slits, in contrast to the behavior of a single strip without slits, for which m_y =0.Comment: 11 pages, 5 figures, revtex

    Magnetic-field and current-density distributions in thin-film superconducting rings and disks

    Full text link
    We show how to calculate the magnetic-field and sheet-current distributions for a thin-film superconducting annular ring (inner radius a, outer radius b, and thickness d<<a) when either the penetration depth obeys lambda < d/2 or, if lambda > d/2, the two-dimensional screening length obeys Lambda = 2 lambda^2/d << a for the following cases: (a) magnetic flux trapped in the hole in the absence of an applied magnetic field, (b) zero magnetic flux in the hole when the ring is subjected to an applied magnetic field, and (c) focusing of magnetic flux into the hole when a magnetic field is applied but no net current flows around the ring. We use a similar method to calculate the magnetic-field and sheet-current distributions and magnetization loops for a thin, bulk-pinning-free superconducting disk (radius b) containing a dome of magnetic flux of radius a when flux entry is impeded by a geometrical barrier.Comment: 10 pages, 13 figure

    Vortex phase transformations probed by the local ac response of Bi_{2}Sr_{2}CaCu_{2}O_{8+\delta} single crystals with various doping

    Full text link
    The linear ac response of the vortex system is measured locally in Bi-2212 single crystals at various doping, using a miniature two-coil mutual-inductance technique. It was found that a step-like change in the local ac response takes place exactly at the first-order transition (FOT) temperature T_{FOT}(H) determined by a global dc magnetization measurement. The T_{FOT}(H) line in the H-T phase diagram becomes steeper with increasing doping. In the higher-field region where the FOT is not observed, the local ac response still shows a broadened but distinct feature, which can be interpreted to mark the growth of a short-range order in the vortex system.Comment: 4 pages, including 5 eps figure

    Advancing the 3Rs in regulatory ecotoxicology: A pragmatic cross-sector approach

    Get PDF
    The ecotoxicity testing of chemicals for prospective environmental safety assessment is an area in which a high number of vertebrates are used across a variety of industry sectors. Refining, reducing, and replacing the use of animals such as fish, birds, and amphibians for this purpose addresses the ethical concerns and the increasing legislative requirements to consider alternative test methods. Members of the UK-based National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs) Ecotoxicology Working Group, consisting of representatives from academia, government organizations, and industry, have worked together over the past 6 y to provide evidence bases to support and advance the application of the 3Rs in regulatory ecotoxicity testing. The group recently held a workshop to identify the areas of testing, demands, and drivers that will have an impact on the future of animal use in regulatory ecotoxicology. As a result of these discussions, we have developed a pragmatic approach to prioritize and realistically address key opportunity areas, to enable progress toward the vision of a reduced reliance on the use of animals in this area of testing. This paper summarizes the findings of this exercise and proposes a pragmatic strategy toward our key long-term goals-the incorporation of reliable alternatives to whole-organism testing into regulations and guidance, and a culture shift toward reduced reliance on vertebrate toxicity testing in routine environmental safety assessment. Integr Environ Assess Manag 2016;12:417-421. © 2015 SETAC

    Analytic Solution for the Critical State in Superconducting Elliptic Films

    Full text link
    A thin superconductor platelet with elliptic shape in a perpendicular magnetic field is considered. Using a method originally applied to circular disks, we obtain an approximate analytic solution for the two-dimensional critical state of this ellipse. In the limits of the circular disk and the long strip this solution is exact, i.e. the current density is constant in the region penetrated by flux. For ellipses with arbitrary axis ratio the obtained current density is constant to typically 0.001, and the magnetic moment deviates by less than 0.001 from the exact value. This analytic solution is thus very accurate. In increasing applied magnetic field, the penetrating flux fronts are approximately concentric ellipses whose axis ratio b/a < 1 decreases and shrinks to zero when the flux front reaches the center, the long axis staying finite in the fully penetrated state. Analytic expressions for these axes, the sheet current, the magnetic moment, and the perpendicular magnetic field are presented and discussed. This solution applies also to superconductors with anisotropic critical current if the anisotropy has a particular, rather realistic form.Comment: Revtex file and 13 postscript figures, gives 10 pages of text with figures built i

    Place-of-residence errors on death certificates for two contiguous U. S. counties

    Get PDF
    BACKGROUND: Based on death certificate data, the Texas Department of Health Bureau of Vital Statistics calculates age adjusted all-cause mortality rates for each Texas county yearly. In 1998 the calculated rates for two adjacent Texas counties was disparate. These counties contain one city (Amarillo) and are identical in size. This study examined the accuracy of recorded county of residence for deaths in the two counties in 1998. In our jurisdiction, the county of residence is assigned by funeral homes. METHODS: A random sample of 20% of death certificates was selected. The accuracy of the county of residence was verified by using a large area map, Tax Appraisal District records, and U.S. Census Bureau databases. Inaccuracies in recording the county or zip code of residence was recorded. RESULTS: Eighteen of 354 (5.4%) death certificates recorded the incorrect county and 21 of 354 (5.9%) of death certificates recorded the zip code improperly. There was a 14.4% county recording error rate for one county compared to a 0.82% for the other county. The zip code error rate was similar for the two counties (5.9% vs. 5.8%). Of the county errors, 83% occurred for addresses within a zip code that contained addresses in both counties. CONCLUSION: This study demonstrated a large error rate (14%) in recording county of residence for deaths in one county. A similar rate was not seen in an adjacent county. This led to significant miscalculation of mortality rates for two counties. We believe that errors may have arisen in part from use of internet programs by funeral homes to assign the county of residence. With some of these programs, the county is determined by zip code, and when a zip code straddles two counties, the program automatically assigns the county whose name appears first in the alphabet. This type of error could be avoided if funeral homes determined the county of residence from Tax Appraisal District or Census Bureau records, both of which are available on the internet. This type of error could also be avoided if vital statistics offices verified the county and zip code of residence using official sources

    Critical State in Thin Anisotropic Superconductors of Arbitrary Shape

    Full text link
    A thin flat superconductor of arbitrary shape and with arbitrary in-plane and out-of-plane anisotropy of flux-line pinning is considered, in an external magnetic field normal to its plane. It is shown that the general three-dimensional critical state problem for this superconductor reduces to the two-dimensional problem of an infinitely thin sample of the same shape but with a modified induction dependence of the critical sheet current. The methods of solving the latter problem are well known. This finding thus enables one to study the critical states in realistic samples of high-Tc superconductors with various types of anisotropic flux-line pinning. As examples, we investigate the critical states of long strips and rectangular platelets of high-Tc superconductors with pinning either by the ab-planes or by extended defects aligned with the c-axis.Comment: 13 pages including 13 figure files in the tex

    Dynamics of Flux Creep in Underdoped Single Crystals of Y_1-xPr_xBa_2Cu_3O_7-d

    Full text link
    Transport as well as magnetic relaxation properties of the mixed state were studied on strongly underdoped Y_1-xPr_xBa_2Cu_3O_7-d crystals. We observed two correlated phenomena - a coupling transition and a transition to quantum creep. The distribution of transport current below the coupling transition is highly nonuniform, which facilitates quantum creep. We speculate that in the mixed state below the coupling transition, where dissipation is nonohmic, the current distribution may be unstable with respect to self-channeling resulting in the formation of very thin current-carrying layers.Comment: 11 pages, 9 figures, Submitted to Phys. Rev.

    PECVD coatings for functionalization of point-of-care biosensor surfaces

    Get PDF
    In early stage disease diagnosis, an accurate and reliable measurement of low concentrations of specific biomarkers is a key need. The detection technique requires the reaction of an antibody, which is generally covalently bound to the biosensor platform, with its antigen. The application of Zeonor ®, a cyclo olefin copolymer (COP) with very low autofluorescence, good optical properties and high precision molding characteristics, as a biosensor platform has been demonstrated recently. Highly reproducible, industrial scale surface chemical modification of the COP plastic for covalent attachment of the biomolecules for specific recognition of the target, together with low non-specific binding of other proteins that may be present in the sample is a key challenge. In this work, the applicability of plasma enhanced chemical vapor deposition (PECVD) process has been demonstrated by depositing varying surface functionalities including amines, carboxylic, mercapto, epoxy and polyethylene glycol functionalities. The plasma functionalized coatings thus created possess both reactive and repellent sites on the biosensor chip, allowing the chip to be configured either for fluorescence or light scattering-based detection or for label-free surface plasmon resonance detection techniques. The versatility of the gas phase deposition process for building sequential chemistries on low cost and disposable plastic chips is presented in detail. © 2011 Elsevier Ltd. All rights reserved
    • …
    corecore