1,171 research outputs found

    Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector

    Full text link
    The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for XENON1T, of which the impact on the detector performance is discussed. All photomultipliers have been tested in a nitrogen atmosphere at cryogenic temperatures, with a subset of the tubes being tested in gaseous and liquid xenon, simulating their operating conditions in the dark matter detector. The performance and evaluation of the tubes in the different environments is reported and the criteria for rejection of PMTs are outlined and quantified.Comment: 24 pages, 16 figure

    Radon daughter removal from PTFE surfaces and its application in liquid xenon detectors

    Get PDF
    Long-lived radon daughters are a critical background source in experiments searching for low-energy rare events. Originating from radon in ambient air, radioactive polonium, bismuth and lead isotopes plate-out on materials that are later employed in the experiment. In this paper, we examine cleaning procedures for their capability to remove radon daughters from PTFE surfaces, a material often used in liquid xenon TPCs. We found a large difference between the removal efficiency obtained for the decay chains of 222^{222}Rn and 220^{220}Rn, respectively. This indicates that the plate-out mechanism has an effect on the cleaning success. While the long-lived 222^{222}Rn daughters could be reduced by a factor of ~2, the removal of 220^{220}Rn daughters was up to 10 times more efficient depending on the treatment. Furthermore, the impact of a nitric acid based PTFE cleaning on the liquid xenon purity is investigated in a small-scale liquid xenon TPC

    Acceptability of new formulations of Corn-Soy Blends and Lipid-based Nutrient Supplements in Province du Passoré, Burkina Faso

    Get PDF
    The objective of this study was to evaluate the acceptability of new formulations of six corn-soy blended flours (CSB) and six lipid-based nutrient supplements (LNS) with different quantities of milk and qualities of soy to be used for the treatment of moderate acute malnutrition (MAM). Furthermore, we wanted to explore the acceptability of foods currently used for the prevention and treatment of malnutrition in Burkina Faso to identify possible barriers that could affect the acceptability of the new formulations of supplementary foods. The study was carried out prior to a randomized controlled trial evaluating the effectiveness of these new formulations. The study involved an observed test-meal and a three-day take-home ration of the experimental food supplements to 6-30-months-old healthy children, followed by questionnaire-based interviews about the acceptability of these supplements. Interviews and focus group discussions were carried out to explore the acceptability of foods currently used for the prevention and treatment of malnutrition. The results suggest that both LNS and CSB products with different quantities of milk and qualities of soy are equally well accepted among healthy children in rural Burkina Faso based on general appreciation of the supplements and organoleptic properties. All experimental foods received good ratings and there was no significant difference between the foods. However, after the take-home ration, 58% of participants receiving CSB reported having left-overs at the end of the day compared to 37% (n=33) of the participants receiving LNS (p=0.004), suggesting that CSB was not as readily consumed as LNS. Yet, both CSB and LNS products were perceived as easy to administer and the frequency of feeding was estimated to be adequate. The study also found that similar foods, used for the prevention and treatment of malnutrition, were well appreciated in the study location. LNS were to a higher degree associated with medicine or foods with medicinal properties, but both LNS and CSB were perceived as beneficial to child health

    Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector

    No full text
    The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for XENON1T, of which the impact on the detector performance is discussed. All photomultipliers have been tested in a nitrogen atmosphere at cryogenic temperatures, with a subset of the tubes being tested in gaseous and liquid xenon, simulating their operating conditions in the dark matter detector. The performance and evaluation of the tubes in the different environments is reported and the criteria for rejection of PMTs are outlined and quantified

    Physicochemical and Biological Characterisation of Diclofenac Oligomeric Poly(3-hydroxyoctanoate) Hybrids as β-TCP Ceramics Modifiers for Bone Tissue Regeneration

    Get PDF
    Nowadays, regenerative medicine faces a major challenge in providing new, functional materials that will meet the characteristics desired to replenish and grow new tissue. Therefore, this study presents new ceramic-polymer composites in which the matrix consists of tricalcium phosphates covered with blends containing a chemically bounded diclofenac with the biocompatible polymer-poly(3-hydroxyoctanoate), P(3HO). Modification of P(3HO) oligomers was confirmed by NMR, IR and XPS. Moreover, obtained oligomers and their blends were subjected to an in-depth characterisation using GPC, TGA, DSC and AFM. Furthermore, we demonstrate that the hydrophobicity and surface free energy values of blends decreased with the amount of diclofenac modified oligomers. Subsequently, the designed composites were used as a substrate for growth of the pre-osteoblast cell line (MC3T3-E1). An in vitro biocompatibility study showed that the composite with the lowest concentration of the proposed drug is within the range assumed to be non-toxic (viability above 70%). Cell proliferation was visualised using the SEM method, whereas the observation of cell penetration into the scaffold was carried out by confocal microscopy. Thus, it can be an ideal new functional bone tissue substitute, allowing not only the regeneration and restoration of the defect but also inhibiting the development of chronic inflammation

    Direct visualization of electroporation-assisted in vivo gene delivery to tumors using intravital microscopy – spatial and time dependent distribution

    Get PDF
    BACKGROUND: Electroporation is currently receiving much attention as a way to increase drug and DNA delivery. Recent studies demonstrated the feasibility of electrogene therapy using a range of therapeutic genes for the treatment of experimental tumors. However, the transfection efficiency of electroporation-assisted DNA delivery is still low compared to viral methods and there is a clear need to optimize this approach. In order to optimize treatment, knowledge about spatial and time dependency of gene expression following delivery is of utmost importance in order to improve gene delivery. Intravital microscopy of tumors growing in dorsal skin fold window chambers is a useful method for monitoring gene transfection, since it allows non-invasive dynamic monitoring of gene expression in tumors in a live animal. METHODS: Intravital microscopy was used to monitor real time spatial distribution of the green fluorescent protein (GFP) and time dependence of transfection efficiency in syngeneic P22 rat tumor model. DNA alone, liposome-DNA complexes and electroporation-assisted DNA delivery using two different sets of electric pulse parameters were compared. RESULTS: Electroporation-assisted DNA delivery using 8 pulses, 600 V/cm, 5 ms, 1 Hz was superior to other methods and resulted in 22% increase in fluorescence intensity in the tumors up to 6 days post-transfection, compared to the non-transfected area in granulation tissue. Functional GFP was detected within 5 h after transfection. Cells expressing GFP were detected throughout the tumor, but not in the surrounding tissue that was not exposed to electric pulses. CONCLUSIONS: Intravital microscopy was demonstrated to be a suitable method for monitoring time and spatial distribution of gene expression in experimental tumors and provided evidence that electroporation-assisted gene delivery using 8 pulses, 600 V/cm, 5 ms, 1 Hz is an effective method, resulting in early onset and homogenous distribution of gene expression in the syngeneic P22 rat tumor model
    • …
    corecore