1,037 research outputs found

    Spatial patterns in timing of the diurnal temperature cycle

    Get PDF
    This paper investigates the structural difference in timing of the diurnal temperature cycle (DTC) over land resulting from choice of measuring device or model framework. It is shown that the timing can be reliably estimated from temporally sparse observations acquired from a constellation of low Earth-orbiting satellites given record lengths of at least three months. Based on a year of data, the spatial patterns of mean DTC timing are compared between temperature estimates from microwave Ka-band, geostationary thermal infrared (TIR), and numerical weather prediction model output from the Global Modeling and Assimilation Office (GMAO). It is found that the spatial patterns can be explained by vegetation effects, sensing depth differences and more speculatively the orientation of orographic relief features. In absolute terms, the GMAO model puts the peak of the DTC on average at 12:50 local solar time, 23 min before TIR with a peak temperature at 13:13 (both averaged over Africa and Europe). Since TIR is the shallowest observation of the land surface, this small difference represents a structural error that possibly affects the model's ability to assimilate observations that are closely tied to the DTC. The equivalent average timing for Ka-band is 13:44, which is influenced by the effect of increased sensing depth in desert areas. For non-desert areas, the Ka-band observations lag the TIR observations by only 15 min, which is in agreement with their respective theoretical sensing depth. The results of this comparison provide insights into the structural differences between temperature measurements and models, and can be used as a first step to account for these differences in a coherent way

    Analysing acoustic model changes for active learning in automatic speech recognition

    Get PDF
    In active learning for Automatic Speech Recognition (ASR), a portion of data is automatically selected for manual transcription. The objective is to improve ASR performance with retrained acoustic models. The standard approaches are based on confidence of individual sentences. In this study, we look into an alternative view on transcript label quality, in which Gaussian Supervector Distance (GSD) is used as a criterion for data selection. GSD is a metric which quantifies how the model was changed during its adaptation. By using an automatic speech recognition transcript derived from an out-of-domain acoustic model, unsupervised adaptation was conducted and GSD was computed. The adapted model is then applied to an audio book transcription task. It is found that GSD provide hints for predicting data transcription quality. A preliminary attempt in active learning proves the effectiveness of GSD selection criterion over random selection, shedding light on its prospective use

    Evidence-based planning and costing palliative care services for children : novel multi-method epidemiological and economic exemplar

    Get PDF
    Background: Children’s palliative care is a relatively new clinical specialty. Its nature is multi-dimensional and its delivery necessarily multi-professional. Numerous diverse public and not-for-profit organisations typically provide services and support. Because services are not centrally coordinated, they are provided in a manner that is inconsistent and incoherent. Since the first children’s hospice opened in 1982, the epidemiology of life-limiting conditions has changed with more children living longer, and many requiring transfer to adult services. Very little is known about the number of children living within any given geographical locality, costs of care, or experiences of children with ongoing palliative care needs and their families. We integrated evidence, and undertook and used novel methodological epidemiological work to develop the first evidence-based and costed commissioning exemplar. Methods: Multi-method epidemiological and economic exemplar from a health and not-for-profit organisation perspective, to estimate numbers of children under 19 years with life-limiting conditions, cost current services, determine child/parent care preferences, and cost choice of end-of-life care at home. Results: The exemplar locality (North Wales) had important gaps in service provision and the clinical network. The estimated annual total cost of current children’s palliative care was about £5.5 million; average annual care cost per child was £22,771 using 2007 prevalence estimates and £2,437- £11,045 using new 2012/13 population-based prevalence estimates. Using population-based prevalence, we estimate 2271 children with a life-limiting condition in the general exemplar population and around 501 children per year with ongoing palliative care needs in contact with hospital services. Around 24 children with a wide range of life-limiting conditions require end-of-life care per year. Choice of end-of-life care at home was requested, which is not currently universally available. We estimated a minimum (based on 1 week of end-of-life care) additional cost of £336,000 per year to provide end-of-life support at home. Were end-of-life care to span 4 weeks, the total annual additional costs increases to £536,500 (2010/11 prices). Conclusions: Findings make a significant contribution to population-based needs assessment and commissioning methodology in children’s palliative care. Further work is needed to determine with greater precision which children in the total population require access to services and when. Half of children who died 2002-7 did not have conditions that met the globally used children's palliative care condition categories, which need revision in light of findings

    Microwave Implementation of the Two-Source Energy Balance Approach for Estimating Evapotranspiration

    Get PDF
    A newly developed microwave (MW) land surface temperature (LST) product is used to substitute thermal infrared (TIR) based LST in the two-source energy balance approach (TSEB) for estimating ET from space. This TSEB land surface scheme, the Atmosphere Land Exchange Inverse (ALEXI) model framework, is an approach that minimizes sensitivity to absolute biases in input records of LST through the analysis of the rate of temperature change in the morning. This experiment is therefore an important test of the ability to retrieve diurnal temperature information from a constellation of satellites with microwave radiometers that together provide 6-8 observations of Ka-band brightness temperature per location per day. This represents the first ever attempt at a global implementation of ALEXI with MW-based LST and is intended as the first step towards providing all-weather capability to the ALEXI framework. The leveraging of all sky capability of MW sensors is the main motivation of this work, as TIR-based ALEXI is limited to clear sky conditions.The analysis is based on a 9-year long record of ALEXI ET generated with MW-LST as an input, which is compared to an existing implementation of the same framework with thermal infrared based LST. In this study, the MW-LST sampling is restricted to the same clear sky days as in the IR-based implementation to be able to analyse the impact of changing the LST dataset separately from the impact of sampling all-sky conditions. The results show that long-term bulk ET estimates agree with a spatial correlation of 92 for total ET in the EuropeAfrica domain and agreement in seasonal (3-month) totals of 83-97 depending on the time of year. Most importantly, the ALEXI-MW also matches ALEXI-IR very closely in terms of 3-month inter-annual anomalies, demonstrating its ability to capture the development and extent of drought conditions. The weekly ET output from the two parallel ALEXI implementations is further compared to a common ground measured reference provided by the FLUXNET consortium. Overall, they indicate a surprisingly close match in both performance metrics (correlation and RMSE) for all but the most challenging sites in terms of spatial heterogeneity and level of aridity. Moreover, merging MW- and IR-based ALEXI may provide estimates of ET with a reduced uncertainty, even during nominally clear sky days. It is concluded that a constellation of MW satellites can effectively be used to provide LST for estimating ET through TSEB, which is an important step towards all-sky satellite-based ET estimates

    Towards an integrated soil moisture drought monitor for East Africa

    Get PDF
    Drought in East Africa is a recurring phenomenon with significant humanitarian impacts. Given the steep climatic gradients, topographic contrasts, general data scarcity, and, in places, political instability that characterize the region, there is a need for spatially distributed, remotely derived monitoring systems to inform national and international drought response. At the same time, the very diversity and data scarcity that necessitate remote monitoring also make it difficult to evaluate the reliability of these systems. Here we apply a suite of remote monitoring techniques to characterize the temporal and spatial evolution of the 2010–2011 Horn of Africa drought. Diverse satellite observations allow for evaluation of meteorological, agricultural, and hydrological aspects of drought, each of which is of interest to different stakeholders. Focusing on soil moisture, we apply triple collocation analysis (TCA) to three independent methods for estimating soil moisture anomalies to characterize relative error between products and to provide a basis for objective data merging. The three soil moisture methods evaluated include microwave remote sensing using the Advanced Microwave Scanning Radiometer – Earth Observing System (AMSR-E) sensor, thermal remote sensing using the Atmosphere-Land Exchange Inverse (ALEXI) surface energy balance algorithm, and physically based land surface modeling using the Noah land surface model. It was found that the three soil moisture monitoring methods yield similar drought anomaly estimates in areas characterized by extremely low or by moderate vegetation cover, particularly during the below-average 2011 long rainy season. Systematic discrepancies were found, however, in regions of moderately low vegetation cover and high vegetation cover, especially during the failed 2010 short rains. The merged, TCA-weighted soil moisture composite product takes advantage of the relative strengths of each method, as judged by the consistency of anomaly estimates across independent methods. This approach holds potential as a remote soil moisture-based drought monitoring system that is robust across the diverse climatic and ecological zones of East Africa

    A continuous source of translationally cold dipolar molecules

    Get PDF
    The Stark interaction of polar molecules with an inhomogeneous electric field is exploited to select slow molecules from a room-temperature reservoir and guide them into an ultrahigh vacuum chamber. A linear electrostatic quadrupole with a curved section selects molecules with small transverse and longitudinal velocities. The source is tested with formaldehyde (H2CO) and deuterated ammonia (ND3). With H2CO a continuous flux is measured of approximately 10^9/s and a longitudinal temperature of a few K. The data are compared with the result of a Monte Carlo simulation.Comment: 4 pages, 4 figures v2: small changes in the abstract, text and references. Figures 1 & 2 regenerated to prevent errors in the pd
    corecore