174 research outputs found

    High resolution and high efficiency coloration of lithium fluoride by soft X-rays irradiation

    Get PDF
    The efficient coloration of LiF material, in the form of bulk and films, by EUV and soft X-rays emitted by a laser-plasma source is demonstrated. The short penetration depth of soft-X-rays is exploited to obtain high spatial resolution luminescent patterns while the high dynamic range of proportionality between X-ray dose and coloration is exploited for using LiF as image detector in micro-radiography and soft X-ray microscopy applications

    Spallative ablation of dielectrics by X-ray laser

    Full text link
    Short laser pulse in wide range of wavelengths, from infrared to X-ray, disturbs electron-ion equilibrium and rises pressure in a heated layer. The case where pulse duration τL\tau_L is shorter than acoustic relaxation time tst_s is considered in the paper. It is shown that this short pulse may cause thermomechanical phenomena such as spallative ablation regardless to wavelength. While the physics of electron-ion relaxation on wavelength and various electron spectra of substances: there are spectra with an energy gap in semiconductors and dielectrics opposed to gapless continuous spectra in metals. The paper describes entire sequence of thermomechanical processes from expansion, nucleation, foaming, and nanostructuring to spallation with particular attention to spallation by X-ray pulse

    Lithium fluoride coloration by laser-plasma soft x-rays: A promising tool for X-ray microscopy and photonics

    Get PDF
    A new imaging detector for EUV or soft-X-ray radiation based on optically stimulated luminescence (OSL) of lithium fluoride (LiF) films or crystals is presented. The first micro-radiography images of biological samples and of meshes obtained on LiF using a laser-plasma source or an X-ray laser are shown, and (up to now) a resolution better than one micron is demonstrated. The dependence of the coloration density vs the deposited X-ray dose is considered and the advantages of this new diagnostic technique for both coherent and non-coherent EUV sources, compared with CCDs detectors, photographic films and photoresists are discussed. This new detector is extremely suitable for laser plasmas and for X-ray lasers sources

    polymer nanostructuring by two photon absorption

    Get PDF
    Two-photon polymerization (2PP) is an innovative technology that in recent years showed a tremendous potential for three-dimensional structuring of photopolymers at the submicron scale. It is based on the nonlinear absorption of ultrashort laser pulses in transparent photosensitive materials. 2PP has been so far exploited in various fields, including photonics, microfluidics, regenerative medicine and MEMS prototyping. The versatility of this technology relies also on the photomaterials; indeed, polymers are easy to process, low cost and they allow the tailoring of their chemical and mechanical properties. 2PP nanotechnology is here exploited to produce micro and nanostructures that can be easily customized both in the geometry and in polymer functionalization. In particular, atomic force microscopy tips are fabricated on top of commercial cantilevers to demonstrate the technology feasibility and customizability. Moreover nanoporous membranes that can be fabricated by 2PP as a single custom product or as a mould for mass production through replica moulding are realized to evaluate the scalability of the fabrication process

    x ray imaging of bio medical samples using laser plasma based x ray sources and lif detector

    Get PDF
    This contribution to ECPD2019 is dedicated to the memory of Anatoly Faenov. During a period of approximately thirteen years 1994–2006, Anatoly and his wife Tatiana Pikuz (simply "Tania" for friends), accepting the frequent invitations of the National Institute for Nuclear Physics (INFN) and of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), cooperated with many Italian research laboratories dedicated to EUV and soft X-ray generation, spread in different towns (L'Aquila, Frascati, Milano, Padova, Pisa, Roma, etc.). In spite of the fact that they could stay in Italy only about one or two months per year, their activity was so intense that more than 50 peer- reviewed publications were generated from their experimental and theoretical work (just considering only the results obtained at L'Aquila and Tor Vergata—Rome Universities and at the ENEA Research Center of Frascati), without mentioning the cultural atmosphere that they stimulated in the field of Science and Humanity. The numerous experimental spectra obtained at ENEA by means of their spherically bent mica spectrometers, together with the corresponding theoretical simulations performed in Moscow, allowed to study the changing role of different excitations mechanisms for various plasma conditions, and to characterize at best the ENEA laser-plasma source for different applications: polychromatic and monochromatic micro-radiography of dried biological samples at 1 keV, soft X-ray contact microscopy (SXCM) of living cells in the water-window spectral region, spectroscopy of hollow atoms, etc. In this memorial paper, the main results of biological samples imaging on lithium fluoride (LiF) detectors, obtained with the ENEA and Tor Vergata University laser-plasma sources, are presented. In particular, the improvement of the micro-radiography and of the SXCM techniques obtained after moving from photoresist detectors and photographic films to lithium fluoride (LiF) detectors are discussed, for both dried and wet biological samples

    Depth Profiling Photoelectron-Spectroscopic Study of an Organic Spin Valve with a Plasma-Modified Pentacene Spacer

    Get PDF
    [[abstract]]We report an enhanced magnetoresistance (MR) in an organic spin valve with an oxygen plasma-treated pentacene (PC) spacer. The spin valve containing PC without the treatment shows no MR effect, whereas those with moderately plasma-treated PC exhibit MR ratios up to 1.64% at room temperature. X-ray photoelectron spectroscopy with depth profiling is utilized to characterize the interfacial electronic properties of the plasma-treated PC spacer which shows the formation of a derivative oxide layer. The results suggest an alternative approach to improve the interface quality and in turn to enhance the MR performance in organic spin valves.[[incitationindex]]SCI[[booktype]]電子

    Infrared near-field microscopy with the Vanderbilt free electron laser: overview and perspectives

    Get PDF
    Scanning near-field optical microscopy (SNOM) makes it routinely possible to overcome the fundamental diffraction limit of standard (far-field) microscopy. Recently, aperture-based infrared SNOM performed in the spectroscopic mode,using the Vanderbilt University free electron laser,started delivering spatially-resolved information on the distribution of chemical species and on other laterally-fluctuating properties.The practical examples presented here show the great potential of this new technique both in materials science and in life sciences

    Evaluating the Impact of Nature-Based Solutions: A Handbook for Practitioners

    Get PDF
    The Handbook aims to provide decision-makers with a comprehensive NBS impact assessment framework, and a robust set of indicators and methodologies to assess impacts of nature-based solutions across 12 societal challenge areas: Climate Resilience; Water Management; Natural and Climate Hazards; Green Space Management; Biodiversity; Air Quality; Place Regeneration; Knowledge and Social Capacity Building for Sustainable Urban Transformation; Participatory Planning and Governance; Social Justice and Social Cohesion; Health and Well-being; New Economic Opportunities and Green Jobs. Indicators have been developed collaboratively by representatives of 17 individual EU-funded NBS projects and collaborating institutions such as the EEA and JRC, as part of the European Taskforce for NBS Impact Assessment, with the four-fold objective of: serving as a reference for relevant EU policies and activities; orient urban practitioners in developing robust impact evaluation frameworks for nature-based solutions at different scales; expand upon the pioneering work of the EKLIPSE framework by providing a comprehensive set of indicators and methodologies; and build the European evidence base regarding NBS impacts. They reflect the state of the art in current scientific research on impacts of nature-based solutions and valid and standardized methods of assessment, as well as the state of play in urban implementation of evaluation frameworks
    corecore