565 research outputs found

    Widening use of dexamethasone implant for the treatment of macular edema

    Get PDF
    Sustained-release intravitreal 0.7 mg dexamethasone (DEX) implant is approved in Europe for the treatment of macular edema related to diabetic retinopathy, branch retinal vein occlusion, central retinal vein occlusion, and non-infectious uveitis. The implant is formulated in a biodegradable copolymer to release the active ingredient within the vitreous chamber for up to 6 months after an intravitreal injection, allowing a prolonged interval of efficacy between injections with a good safety profile. Various other ocular pathologies with inflammatory etio­pathogeneses associated with macular edema have been treated by DEX implant, including neovascular age-related macular degeneration, Irvine–Gass syndrome, vasoproliferative retinal tumors, retinal telangiectasia, Coats’ disease, radiation maculopathy, retinitis pigmentosa, and macular edema secondary to scleral buckling and pars plana vitrectomy. We undertook a review to provide a comprehensive collection of all of the diseases that benefit from the use of the sustained-release DEX implant, alone or in combination with concomitant therapies. A MEDLINE search revealed lack of randomized controlled trials related to these indications. Therefore we included and analyzed all available studies (retrospective and prospective, com­parative and non-comparative, randomized and nonrandomized, single center and multicenter, and case report). There are reports in the literature of the use of DEX implant across a range of macular edema-related pathologies, with their clinical experience supporting the use of DEX implant on a case-by-case basis with the aim of improving patient outcomes in many macular pathologies. As many of the reported macular pathologies are difficult to treat, a new treat­ment option that has a beneficial influence on the clinical course of the disease may be useful in clinical practice

    Direct X-ray photoconversion in flexible organic thin film devices operated below 1 v

    Get PDF
    The application of organic electronic materials for the detection of ionizing radiations is very appealing thanks to their mechanical flexibility, low-cost and simple processing in comparison to their inorganic counterpart. In this work we investigate the direct X-ray photoconversion process in organic thin film photoconductors. The devices are realized by drop casting solution-processed bis-(triisopropylsilylethynyl)pentacene (TIPS-pentacene) onto flexible plastic substrates patterned with metal electrodes; they exhibit a strong sensitivity to X-rays despite the low X-ray photon absorption typical of low-Z organic materials. We propose a model, based on the accumulation of photogenerated charges and photoconductive gain, able to describe the magnitude as well as the dynamics of the X-ray-induced photocurrent. This finding allows us to fabricate and test a flexible 2 Ă— 2 pixelated X-ray detector operating at 0.2 V, with gain and sensitivity up to 4.7 Ă— 10 4 and 77,000 nC mGy 1 cm 3, respectively

    Submicrometer-Channel Organic Transistors with MHz Operation Range on Flexible Substrates by a Low-Resolution Fabrication Technique

    Get PDF
    In this paper, the development of a simple and reproducible approach for the fabrication of n-type organic field-effect transistors with a 350 nm-long channel on flexible substrates is reported. The critical feature of the device, the channel length, is obtained using a self-alignment process that exploits the vertical step of a plasma-etched thin Parylene C layer, according to the so-called step-edge architecture. The fabricated devices can operate in continuous mode and show an average and maximum transition frequency of 2.5 MHz and 5.5 MHz, respectively. The possibility of easily obtaining high-performing, short channel organic transistors on flexible substrates, without the use of expensive and high-resolution techniques, represents an interesting step toward the miniaturization of flexible circuits in the field of large-area organic electronics

    TIE: A Community-Oriented Traffic Classification Platform

    Full text link
    Abstract — During the last years the research on network traffic classification has become very active. The research community, moved by increasing difficulties in the automated identification of network traffic and by concerns related to user privacy, started to investigate and propose classification approaches alternative to port-based and payload-based techniques. Despite the large quantity of works published in the past few years on this topic, very few implementations targeting alternative approaches were made available to the community. Moreover, most approaches proposed in literature suffer of problems related to the ability of evaluating and comparing them. In this paper we present a novel community-oriented software for traffic classification called TIE, which aims at becoming a common tool for the fair evaluation and comparison of different techniques and at fostering the sharing of common implementations and data. Moreover, TIE supports the combi-nation of more classification plugins in order to build multi-classifier systems, and its architecture is designed to allow online traffic classification. In this paper, we also present the implementation of two basic techniques as classification plugins, which are already distributed with TIE. Finally we report on the development of several classification plugins, implementing novel classification techniques, carried out through collaborations with other research groups. I

    Efficacy of Three Different Prophylactic Treatments for Postoperative Nausea and Vomiting after Vitrectomy: A Randomized Clinical Trial

    Get PDF
    Postoperative nausea and vomiting (PONV) after vitreoretinal surgery may potentially be associated with severe complications, such as suprachoroidal hemorrhage. The purpose of the present multicenter clinical trial (NCT02386059) was to assess the efficacy of three different prophylactic treatments for PONV after vitrectomy under local anesthesia. Patients undergoing primary vitrectomy were randomized to the control arm or to one of the treatment arms (4 mg ondansetron, 4 mg dexamethasone, combination of the two drugs). The primary outcome measure was the proportion of complete response (no nausea, no vomiting, no retching, and no use of antiemetic rescue medication) during 24 h after vitrectomy. Secondary outcomes included the severity standardized score of PONV, postoperative pain standardized score, and rate of ocular and non-ocular adverse events. Baseline demographics of the 1287 patients were comparable between the four arms. The combined therapy group showed a statistically significant lower incidence of PONV compared to the placebo and monotherapy (p < 0.001). PONV severity was also reduced in the combination group compared to the others (p < 0.001). Postoperative pain scores and adverse events were comparable among the four groups. Combined therapy with dexamethasone and ondansetron was the most effective treatment for reducing the incidence and severity of PONV in patients undergoing vitrectomy under local anesthesia

    Direct imaging of defect formation in strained organic flexible electronics by Scanning Kelvin Probe Microscopy

    Get PDF
    The development of new materials and devices for flexible electronics depends crucially on the understanding of how strain affects electronic material properties at the nano-scale. Scanning Kelvin-Probe Microscopy (SKPM) is a unique technique for nanoelectronic investigations as it combines non-invasive measurement of surface topography and surface electrical potential. Here we show that SKPM in non-contact mode is feasible on deformed flexible samples and allows to identify strain induced electronic defects. As an example we apply the technique to investigate the strain response of organic thin film transistors containing TIPS-pentacene patterned on polymer foils. Controlled surface strain is induced in the semiconducting layer by bending the transistor substrate. The amount of local strain is quantified by a mathematical model describing the bending mechanics. We find that the step-wise reduction of device performance at critical bending radii is caused by the formation of nano-cracks in the microcrystal morphology of the TIPS-pentacene film. The cracks are easily identified due to the abrupt variation in SKPM surface potential caused by a local increase in resistance. Importantly, the strong surface adhesion of microcrystals to the elastic dielectric allows to maintain a conductive path also after fracture thus providing the opportunity to attenuate strain effects

    Secondary Vitrectomy with Internal Limiting Membrane Plug due to Persistent Full-Thickness Macular Hole OCT-Angiography and Microperimetry Features: Case Series

    Get PDF
    Purpose. To study the features in OCT-angiography and microperimetry in eyes with persistent full-thickness macular hole (FTMH) closed with the secondary plana vitrectomy (PPV) with autologous internal limiting membrane (ILM) plug. Methods. Secondary PPV was performed with closing the persistent FTMH with ILM plug, C3F8 tamponade, and face-down positioning. Four patients were followed for 6 months with best corrected visual acuity (BCVA) measurement, SD-OCT and OCT-A, and microperimetry. The results were compared with the fellow eye; in two patients, it was the healthy eye, and in two remaining eyes, successfully closed FTMH after primary PPV. Results. ILM flap was integrated in all cases with V-shape of closure, and atrophy was found in one case, with the largest diameter of FTMH. BCVA improved in two cases and remained the same in two cases. In OCT-A, the area of foveal avascular zone (FAZ) was larger, and foveal vessel density (FVDS) was smaller in eyes after secondary PPV in comparison to fellow eyes. In microperimetry, retinal sensitivity was lower in eyes after secondary PPV, and eccentric fixation was found in 2 of 4 patients. Conclusion. Although the anatomical results of repeated surgeries of FTMH with ILM plug are favorable, visual function results may be limited. Secondary closure of FTMH with ILM plug may lead to atrophy, changes in the macular vasculature, and eccentric fixation. The trial is registered with NCT03701542
    • …
    corecore