63 research outputs found

    Optimization-based method of dividing the network development costs

    Full text link

    Atomic layer deposition: Low temperature process well adapted to ULSI and TFT technologies

    Get PDF
    The high k dielectrics is an important materials to be integrate in future Ultra Large Scale Integration (ULSI) and future TFT technology. Indeed, to keep on the Moore\u27s Law curve, the reduction of silicon oxide (SiO2) thickness still required, but this reduction is hindered by tunneling current leakage limit. Consequently, it is important to replace SiO2 by another materials with high dielectric constant. The use of this material in manufacturing of gate dielectric in Thin-film transistor (TFT) and in Complementary Metal Oxide Semiconductor (CMOS) will increase gate capacitance with maintaining a low leakage current. Titanium dioxide is a good candidate due to its high dielectric constant in its rutile crystalline phase (180).This rutile structure is obtained at low temperature (250°C) by ALD deposition when TiO2 is deposited on ruthenium dioxide (RuO2) layer thanks to the small lattice mismatch between these two materials

    Information Management within the LHC Hardware Commissioning Project

    Get PDF
    The core task of the commissioning of the LHC technical systems was the individual test of the 1572 superconducting circuits of the collider, the powering tests. The two objectives of these tests were the validation of the different sub-systems making each superconducting circuit as well as the validation of the superconducting elements of the circuits in their final configuration in the tunnel. A wide set of software applications were developed by the team in charge of coordinating the powering activities (Hardware Commissioning Coordination) in order to manage the amount of information required for the preparation, execution and traceability of the tests. In all the cases special care was taken in order to keep the tools consistent with the LHC quality assurance policy, avoid redundancies between applications, ensure integrity and coherence of the test results and optimise their usability within an accelerator operation environment. This paper describes the main characteristics of these tools; it details their positive impact on the completion on time of the LHC Hardware Commissioning Project and presents usage being envisaged during the coming years of operation of the LHC

    Mechanisms of attenuation of pulmonary V'O_{2} slow component in humans after prolonged endurance training

    Get PDF
    In this study we have examined the effect of prolonged endurance training program on the pulmonary oxygen uptake (V'O2 ) kinetics during heavy-intensity cycling-exercise and its impact on maximal cycling and running performance. Twelve healthy, physically active men (mean\ub1SD: age 22.33\ub11.44 years, V'O2peak 3198\ub1458 mL \ub7 min-1 ) performed an endurance training composed mainly of moderate-intensity cycling, lasting 20 weeks. Training resulted in a decrease (by 3c5%, P = 0.027) in V'O2 during prior low-intensity exercise (20 W) and in shortening of \u3c4 p of the V'O2 on-kinetics (30.1\ub15.9 s vs. 25.4\ub11.5 s, P = 0.007) during subsequent heavy-intensity cycling. This was accompanied by a decrease of the slow component of V'O2 on-kinetics by 49% (P = 0.001) and a decrease in the end-exercise V'O2 by 3c5% (P = 0.005). An increase (P = 0.02) in the vascular endothelial growth factor receptor 2 mRNA level and a tendency (P = 0.06) to higher capillary-to-fiber ratio in the vastus lateralis muscle were found after training (n = 11). No significant effect of training on the V'O2peak was found (P = 0.12). However, the power output reached at the lactate threshold increased by 19% (P = 0.01). The power output obtained at the V'O2peak increased by 14% (P = 0.003) and the time of 1,500-m performance decreased by 5% (P = 0.001). Computer modeling of the skeletal muscle bioenergetic system suggests that the training-induced decrease in the slow component of V'O2 on-kinetics found in the present study is mainly caused by two factors: an intensification of the each-step activation (ESA) of oxidative phosphorylation (OXPHOS) complexes after training and decrease in the "additional" ATP usage rising gradually during heavy-intensity exercise

    Dental Health and Mortality in People With End-Stage Kidney Disease Treated With Hemodialysis: A Multinational Cohort Study

    Get PDF
    Background Dental disease is more extensive in adults with chronic kidney disease, but whether dental health and behaviors are associated with survival in the setting of hemodialysis is unknown. Study Design Prospective multinational cohort. Setting & Participants 4,205 adults treated with long-term hemodialysis, 2010 to 2012 (Oral Diseases in Hemodialysis [ORAL-D] Study). Predictors Dental health as assessed by a standardized dental examination using World Health Organization guidelines and personal oral care, including edentulousness; decayed, missing, and filled teeth index; teeth brushing and flossing; and dental health consultation. Outcomes All-cause and cardiovascular mortality at 12 months after dental assessment. Measurements Multivariable-adjusted Cox proportional hazards regression models fitted with shared frailty to account for clustering of mortality risk within countries. Results During a mean follow-up of 22.1 months, 942 deaths occurred, including 477 cardiovascular deaths. Edentulousness (adjusted HR, 1.29; 95% CI, 1.10-1.51) and decayed, missing, or filled teeth score ≥ 14 (adjusted HR, 1.70; 95% CI, 1.33-2.17) were associated with early all-cause mortality, while dental flossing, using mouthwash, brushing teeth daily, spending at least 2 minutes on oral hygiene daily, changing a toothbrush at least every 3 months, and visiting a dentist within the past 6 months (adjusted HRs of 0.52 [95% CI, 0.32-0.85], 0.79 [95% CI, 0.64-0.97], 0.76 [95% CI, 0.58-0.99], 0.84 [95% CI, 0.71-0.99], 0.79 [95% CI, 0.65-0.95], and 0.79 [95% CI, 0.65-0.96], respectively) were associated with better survival. Results for cardiovascular mortality were similar. Limitations Convenience sample of clinics. Conclusions In adults treated with hemodialysis, poorer dental health was associated with early death, whereas preventive dental health practices were associated with longer survival
    corecore