13 research outputs found

    Pitfalls and premature failure of the Freedom SOLO stentless valve

    Get PDF
    OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcom

    Framework and baseline examination of the German National Cohort (NAKO)

    Get PDF
    The German National Cohort (NAKO) is a multidisciplinary, population-based prospective cohort study that aims to investigate the causes of widespread diseases, identify risk factors and improve early detection and prevention of disease. Specifically, NAKO is designed to identify novel and better characterize established risk and protection factors for the development of cardiovascular diseases, cancer, diabetes, neurodegenerative and psychiatric diseases, musculoskeletal diseases, respiratory and infectious diseases in a random sample of the general population. Between 2014 and 2019, a total of 205,415 men and women aged 19–74 years were recruited and examined in 18 study centres in Germany. The baseline assessment included a face-to-face interview, self-administered questionnaires and a wide range of biomedical examinations. Biomaterials were collected from all participants including serum, EDTA plasma, buffy coats, RNA and erythrocytes, urine, saliva, nasal swabs and stool. In 56,971 participants, an intensified examination programme was implemented. Whole-body 3T magnetic resonance imaging was performed in 30,861 participants on dedicated scanners. NAKO collects follow-up information on incident diseases through a combination of active follow-up using self-report via written questionnaires at 2–3 year intervals and passive follow-up via record linkages. All study participants are invited for re-examinations at the study centres in 4–5 year intervals. Thereby, longitudinal information on changes in risk factor profiles and in vascular, cardiac, metabolic, neurocognitive, pulmonary and sensory function is collected. NAKO is a major resource for population-based epidemiology to identify new and tailored strategies for early detection, prediction, prevention and treatment of major diseases for the next 30 years. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10654-022-00890-5

    Herztransplantation - Goldstandard trotz Alternativen: Herzersatzverfahren

    No full text
    Weltweit leiden etwa 25 Millionen Menschen unter einer Herzinsuffizienz. Deren steigende Prävalenz ist auf die Fortschritte der Medizin und die höhere Lebenserwartung der Bevölkerung zurückzuführen. Während eine optimale medikamentöse Therapie der wichtigste Eckpfeiler in der Behandlung der Herzinsuffizienz ist, stellt die Herztransplantation auch heute noch die beste Option in der Behandlung der terminalen Herzinsuffizienz dar, wenn sämtliche konservative Möglichkeiten ausgeschöpft sind

    Adding vancomycin to perioperative prophylaxis decreases deep sternal wound infections in high-risk cardiac surgery patients.

    No full text
    OBJECTIVES Perioperative prophylaxis with cephalosporins reduces sternal wound infections (SWIs) after cardiac surgery. However, more than 50% of coagulase-negative staphylococci, an important pathogen, are cephalosporin resistant. The aim of this study was to determine the impact of adjunctive vancomycin on SWIs in high-risk patients. METHODS We conducted a pre- and postintervention study in an academic hospital. Preintervention (2010-2011), all patients received prophylaxis with 1.5 g of cefuroxime for 48 h. During the intervention period (2012-2013), high-risk patients additionally received 1 g of vancomycin. High-risk status was defined as body mass index ≤18 or ≥ 30 kg/m2, reoperation, renal failure, diabetes mellitus, chronic obstructive pulmonary disease or immunosuppressive medication. Time series analysis was performed to study SWI trends and logistic regression to determine the effect of adding vancomycin adjusting for high-risk status. RESULTS A total of 3902 consecutive patients (n = 1915 preintervention and n = 1987 postintervention) were included, of which 1493 (38%) patients were high-risk patients. In the high-risk group, 61 of 711 (8.6%) patients had SWI before and 30 of 782 (3.8%) patients after the intervention. Focusing on deep SWI (DSWI), 33 of 711 (4.6%) patients had DSWI before and 13 of 782 (1.7%) patients afterwards; the absolute risk difference of 2.9% yielded a number-needed-to-treat of 34 to prevent 1 DSWI. Corrected for high-risk status, adding vancomycin significantly reduced the overall SWI rate (odds ratio 0.42, 95% confidence interval 0.26-0.67; P < 0.001) and the subset of DSWI (odds ratio 0.30, 95% confidence interval 0.14-0.62; P = 0.001). The rate of SWI in low-risk patients remained unchanged. CONCLUSIONS Adding vancomycin to standard antibiotic prophylaxis in high-risk patients significantly reduced DSWI after cardiac surgery

    Reduced Permanent Pacemaker Implantation in Patients With Stentless Freedom SOLO Compared With Stented Perimount Magna Aortic Bioprostheses: A Propensity Score Weighted Analysis.

    No full text
    OBJECTIVES Postoperative permanent pacemaker implantation (PPI) after conventional aortic valve replacement (AVR), due to new-onset severe conduction system disorders, is required in approximately 7% of patients. This study investigated the need for PPI after AVR with conventional stented Perimount Magna compared with the Freedom SOLO (FS) stentless valve that uses a strictly supra-annular, subcoronary running suture implantation technique, sparing the vulnerable interleaflet triangles in the region of the septum membranaceum. METHODS A total of 413 consecutive patients (71.4±9.2 yrs, 178 [43.1%] female) underwent isolated AVR using the stented Perimount Magna (n=264) or the stentless FS (n=149) bioprosthesis. Propensity score weighted analysis was used to account for patient-specific and procedural-specific variables, and to identify the prosthesis-specific need for early postoperative PPI within 30 days of AVR. RESULTS Twenty (20) patients required PPI, which was associated with longer intensive care unit (2.1±1.7 vs 1.5±3.0 days, p<0.001) and overall hospital stays (13.8±5.2 vs 10.7±5.3 days, p<0.001) compared with no PPI. Propensity weighted logistic regression including cross-clamp times identified that use of the stented Perimount Magna was associated with increased need for PPI, as compared with the FS, with an odds ratio 5.8 (95% CI, 1.09-30.76; p=0.039). CONCLUSIONS After corrections for all plausible confounders, AVR with the stented Perimount valve was associated with an odds ratio of almost 6 for an increased early postoperative need for pacemaker implantation compared with the FS stentless valve. This finding can be explained by the conventional implantation technique, which is potentially associated with mechanical trauma to the conducting system

    Pitfalls and premature failure of the Freedom SOLO stentless valve.

    Get PDF
    OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome

    The Freedom SOLO bovine pericardial stentless valve: Single-center experience, outcome and long-term durability

    Get PDF
    Abstract Objectives We report our institutional experience and long-term results with the Sorin Freedom SOLO bovine pericardial stentless bioprosthesis. Methods Between January 2005 and November 2009, 149 patients (mean age 73.6±8.7 years, 68 [45.6%] female) underwent isolated (n=75) or combined (n=74) aortic valve replacement (AVR) using the SOLO in our institution. Follow-up was 100% complete with an average follow-up time of 5.9±2.6 years (maximum 9.6 years) and a total of 885.3 patient years. Results Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n=1] and 4.0% for combined procedures [n=3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2±23.0 mmHg (48.6 ± 16.3 mmHg) decreased to 15.6±5.4 (8.8±3.0) after AVR, and remained low for up to 9 years. The postoperative effective orifice area (EOA) was 1.6 ±0.57 cm2, 1.90±0.45 cm2, 2.12±0.48 cm2 and 2.20±0.66 cm2 for the valve sizes 21, 23, 25 and 27, respectively; with absence of severe prosthesis-patient-mismatch (PPM) and 0.7% (n=1) moderate PPM. During follow-up, Twenty-six patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation and SVD at 9 years averaged 0.57 [0.47‒0.66], 0.82 [0.69‒0.90] and 0.70 [0.57‒0.79], respectively. Conclusions The Freedom SOLO stentless aortic valve is safe to implant and shows excellent early and mid-term hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5 ̶ 6 years and the need for explantation increased markedly, suggesting low durability

    The endogenous cannabinoid system affects energy balance via central orexigenic drive and peripheral lipogenesis

    No full text
    The cannabinoid receptor type 1 (CB1) and its endogenous ligands, the endocannabinoids, are involved in the regulation of food intake. Here we show that the lack of CB1 in mice with a disrupted CB1 gene causes hypophagia and leanness. As compared with WT (CB1(+/+)) littermates, mice lacking CB1 (CB1(–/–)) exhibited reduced spontaneous caloric intake and, as a consequence of reduced total fat mass, decreased body weight. In young CB1(–/–) mice, the lean phenotype is predominantly caused by decreased caloric intake, whereas in adult CB1(–/–) mice, metabolic factors appear to contribute to the lean phenotype. No significant differences between genotypes were detected regarding locomotor activity, body temperature, or energy expenditure. Hypothalamic CB1 mRNA was found to be coexpressed with neuropeptides known to modulate food intake, such as corticotropin-releasing hormone (CRH), cocaine-amphetamine–regulated transcript (CART), melanin-concentrating hormone (MCH), and prepro-orexin, indicating a possible role for endocannabinoid receptors within central networks governing appetite. CB1(–/–) mice showed significantly increased CRH mRNA levels in the paraventricular nucleus and reduced CART mRNA levels in the dorsomedial and lateral hypothalamic areas. CB1 was also detected in epidydimal mouse adipocytes, and CB1-specific activation enhanced lipogenesis in primary adipocyte cultures. Our results indicate that the cannabinoid system is an essential endogenous regulator of energy homeostasis via central orexigenic as well as peripheral lipogenic mechanisms and might therefore represent a promising target to treat diseases characterized by impaired energy balance

    Development and application of home cage monitoring in laboratory mice and rats: a systematic review

    No full text
    We are conducting a systematic review on home cage monitoring in laboratory mice and rats. A major advantage of home cage monitoring is that the animals can be examined in their home environment, which reduces stress and allows to monitor the animals 24/7. Moreover, this approach minimizes the influence of the human presence on the animals’ behavior. Therefore, home cage-based monitoring is interesting for phenotyping in mice and rats since it may reduce data variability and improve reproducibility. In addition, it can provide a useful tool for welfare assessment. The requirements for home cage monitoring changed over the last decades driven by technology and digitalization. The goal of this systematic review is to identify these historical changes and describe the current state of the art. After phase 1 (title/Abstract screening), it was decided to perform phase 2 (full text screening) and phase 3 (data extraction) simultaneously. Therefore, an updated protocol was uploaded
    corecore