28 research outputs found

    Atrial Natriuretic Peptide Induces Postprandial Lipid Oxidation in Humans

    Get PDF
    OBJECTIVE—Atrial natriuretic peptide (ANP) regulates arterial blood pressure. In addition, ANP has recently been shown to promote human adipose tissue lipolysis through cGMP-mediated hormone-sensitive lipase activation. We hypothesized that ANP increases postprandial free fatty acid (FFA) availability and energy expenditure while decreasing arterial blood pressure

    Identification, validation and clinical implementation of cancer biomarkers: Translational strategies of the EORTC PathoBiology Group

    Get PDF
    AbstractThe increasing demand for personalized cancer therapy requires a strong, intense, and continuous collaboration between pre-clinical and clinical investigators. As a part of the EORTC Translational Research Divison, the EORTC PathoBiology Group (EORTC PBG), focuses on discovery and validation of cancer biomarkers, providing both scientific evidence as well as quality assurance. The clinically relevant target-identification and validation studies carried out in the last decades within the EORTC PBG represent a paradigm for EORTC studies in which laboratory investigations on human biologic material are used to support the development of drugs directed to defined target molecules. The experience acquired within the EORTC PBG with respect to standardization of cancer biomarker test kits and reagents, quality assessment/assurance of cancer biomarker determinations, development of standard operating procedures for assessment of these markers as well as instruction of methodologies and teaching of ethical issues represent a valuable contribution of the EORTC PBG to the onco-translational strategies of the EORTC

    Differential Effects of Environmental and Genetic Factors on T and B Cell Immune Traits

    Get PDF
    Effective immunity requires a complex network of cellular and humoral components that interact with each other and are influenced by different environmental and host factors. We used a systems biology approach to comprehensively assess the impact of environmental and genetic factors on immune cell populations in peripheral blood, including associations with immunoglobulin concentrations, from ∼500 healthy volunteers from the Human Functional Genomics Project. Genetic heritability estimation showed that variations in T cell numbers are more strongly driven by genetic factors, while B cell counts are more environmentally influenced. Quantitative trait loci (QTL) mapping identified eight independent genomic loci associated with leukocyte count variation, including four associations with T and B cell subtypes. The QTLs identified were enriched among genome-wide association study (GWAS) SNPs reported to increase susceptibility to immune-mediated diseases. Our systems approach provides insights into cellular and humoral immune trait variability in humans

    Evaluation of the highly sensitive Roche thyroglobulin II assay and establishment of a reference limit for thyroglobulin-negative patient samples

    Get PDF
    Objectives: Thyroglobulin (Tg) measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC) after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman–Coulter). Design and methods: Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI) evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL) for the Elecsys Tg II assay. Results: Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04–500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. Conclusions: In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence. Keywords: Thyroglobulin, Roche Elecsys Tg II assay, validation, reporting limi

    Plasma metanephrine for assessing the selectivity of adrenal venous sampling

    No full text
    Item does not contain fulltextAdrenal vein sampling is used to establish the origins of excess production of adrenal hormones in primary aldosteronism. Correct catheter positioning is confirmed using adrenal vein measurements of cortisol, but this parameter is not always reliable. Plasma metanephrine represents an alternative parameter. The objective of our study was to determine the use of plasma metanephrine concentrations to establish correct catheter positioning during adrenal vein sampling with and without cosyntropin stimulation. We included 52 cosyntropin-stimulated and 34 nonstimulated sequential procedures. Plasma cortisol and metanephrine concentrations were measured in adrenal and peripheral venous samples. Success rates of sampling, using an adrenal to peripheral cortisol selectivity index of 3.0, were compared with success rates of metanephrine using a selectivity index determined by receiver operating characteristic curve analysis. Among procedures assessed as selective using cortisol, the adrenal to peripheral vein ratio of metanephrine was 6-fold higher than that of cortisol (94.0 versus 15.5; P<0.0001). There were significant positive relationships between adrenal to peripheral vein ratios of cortisol and metanephrine for cosyntropin-stimulated samplings but not for nonstimulated samplings. Receiver operating characteristic curve analysis indicated a plasma metanephrine selectivity index cutoff of 12. Using this cutoff, concordance in sampling success rates determined by cortisol and metanephrine was substantially higher in cosyntropin-stimulated than in nonstimulated samplings (98% versus 59%). For the latter procedures, sampling success rates determined by metanephrine were higher (P<0.01) than those determined by cortisol (91% versus 56%). In conclusion, metanephrine provides a superior analyte compared with cortisol in assessing the selectivity of adrenal vein sampling during procedures without cosyntropin stimulation
    corecore