15 research outputs found

    The Effectiviness of Ketapang (Terminalia Cattapa L.) Leave Extract for the Treatment of Aeromonas Salmonicida Infection in Catfish (Pangasioniodon Hypophthalmus)

    Full text link
    Catfish is one of the fish species with certain advantages that attract the farmers interest to culture. The species becomes popular following the successful spawning in the pond. Additionally, catfishes have high economic value due to their rapid growth and response to good artificial feed. Their farming activities are inseparable from concerns about their potential diseases. Diseases in farmed fish can be caused by fungi, parasites, bacteria and viruses. One type of bacterium to take serious control is Aeromonas salmonicida. This pathogenic bacteria may cause furuncle and death of farmed fish. The use of ketapang leaves is effective in inhibiting or killing the pathogenic A. salmonicida in catfish. In the present study, each test used a sample of 10 catfishes of approximately 10 cm in size. Parameters of the test consist of survival rates and pathologic lesions. The feed treatment consisted of ketapang leaf extract in concentrations of 100, 200, and 300 mg / ml, and a positive control and a negative control. Each treatment consisted of 3 replicates, and were analyzed statistically. The results indicated that the LD50 (Lethal Dose), MIC (Minimum Inhibitory Concentration) and MBC (Minimum Bactericidal Concentration) are 107 cfu/ml, 50 mg/ml and 100 mg/ml, respectively. The most effective concentration of ketapang leaf for the treatment of A. salmonicida infection in the catfish is 200 mg/ml. This is indicated by the highest level of catfish survival and the lowest rate of the pathologic lesions

    Perhitungan Struktur Hotel 11 Lantai Jalan Teuku Umar Pontianak

    Get PDF
    Seiring perkembangan ilmu pengetahuan, maka peraturan-peraturan yang mengatur mengenai konstruksi bangunan juga terus diperbaharui sesuai dengan perkembangan zaman. Salah satunya adalah dalam bidang gempa dimana sebelumnya Kalimantan Barat termasuk dalam wilayah bebas gempa, namun sesuai dengan perkembangan yang ada maka peraturan gempa yang telah diperbaharui tahun 2012 menetapkan Kalimantan Barat sebagai daerah yang berpotensi gempa namun dengan skala yang sangat kecil, hal ini dikarenakan tidak ada daerah yang bisa lepas sepenuhnya dari gempa. Sebagai perencana harus merencanakan struktur bangunan mengacu pada peraturan yang berlaku, dalam hal ini bangunan yang akan ditinjau adalah hotel 11 lantai di jalan Teuku Umar Pontianak yang menggunakan konstruksi beton bertulang. Dalam analisis, sistem pembebanan yang akan dibebankan pada gedung adalah sistem pembebanan horizontal mencakup beban gempa dan angin, dan pembebanan vertikal mencakup beban hidup dan beban mati baik itu berat sendiri struktur maupun beban mati tambahan sebagai akibat dari penggunaan gedung. Analisis struktur dibantu dengan aplikasi komputer. Hasil desain struktur berupa dimensi elemen-elemen struktur utama yang efektif dan efisien tahan terhadap gempa. Struktur tangga dihitung terpisah dari struktur utama. Fondasi dianggap tidak menerima gaya lentur sehingga dimodelkan sebagai sendi. Analisis struktur meliputi pelat, balok, kolom, dan fondasi. Dari hasil perhitungan diperoleh jumlah titik fondasi minipile, dimensi pelat, kolom, dan balok pada struktur yang telah dikerjakan

    Perhitungan Struktur Beton Bertulang Gedung Kantor Sewa Delapan Lantai di Pontianak

    Get PDF
    Pada penulisan tugas akhir ini penulis merencanakan gedung kantor sewa 8 lantai di Jalan Sisingamangaraja Kota Pontianak berdasarkan lokasi data tanah yang digunakan. Perencanaan gedung kantor sewa ini menggunakan spesifikasi perencanaan seperti mutu beton sebesar 25 MPa dan mutu baja sebesar 400 MPa. Standar perencanaan yang digunakan meliputi SNI 2847-2013 “Persyaratan beton struktural untuk bangunan gedung” dan SNI 1726-2012 “Tata cara perencanaan ketahanan gempa untuk bangunan gedung dan non gedung” dan juga PPPURG 1987 untuk pembebanan struktur. Dalam analisis, sistem pembebanan yang akan dibebankan pada gedung adalah sistem pembebanan vertikal berupa beban mati dan beban hidup serta beban horizontal berupa beban gempa dan analisis struktur dibantu dengan bantuan program komputer. Dari hasil analisis struktur diperoleh kesimpulan meliputi pelat, balok, kolom dan pondasi, untuk pelat lantai 1 hingga lantai atap setebal 110 mm dan untuk pelat lantai atap penthouse setebal 100 mm, sedangkan untuk balok induk berukuran 35/70, balok anak 1 berukuran 30/60, balok anak 2 berukuran 25/50 dan balok anak 3 berukuran 20/40, untuk kolom lantai 1-3 berukuran 70/70, dan kolom lantai 4-6 berukuran 65/65, kolom 7-8 berukuran 55/55, serta untuk pondasi menggunakan pondasi tiang pancang (pile) yang tiap titiknya berkisar dari 6 s/d 52 tiang pancang

    Studi Eksperimental Beton Adukan Kering dengan Menggunakan Metode Pipa Berkatup pada Air Gambut

    Full text link
    The development of increasingly advanced technology in all fields, including the field of construction. be it residential, office buildings, bridges, highways, dams, ports and so on. Effect of water level at the time of casting, often become problems and obstacles for planners in determining the characteristics of the concrete to be used in the construction. Investigators therefore conducted research to test specimens of concrete with compressive strength of concrete dried mortarusing peat water with the method of casting pipe with valves, where in the mold (cylinder) there are puddles of peat 50% of the mold, with a view to determine the compressive strength of concrete driedmortarand influence on the amount of peat puddles on the formwork (cylinder). In the manufacture of test specimens using ACI method of normal concrete with plan compressive strength of 25 MPa. Where cement, fine and coarse aggregates mixed with the water needs of normal concrete mix design. Casting method is done by pouring concrete into a mold to dry mixture contained 50% of the puddle prints. 15 cm, height 30 cm. Diamater Test objects are made cylindrical with Testing / testing includes testing the compressive strength and modulus of elasticity test. As a comparison is made also samples of normal concrete and concrete dry peat water with direct pour pipe methods. From the research value of the concrete compressive strength of the dried mortar using peat water with a variable water level of 50% obtained average value of compressive strength characteristics - average 25 MPa for normal concrete, 11.06 MPa for dried concrete peat valves and 8.85 MPafor dry concrete without valve , Water uptake value per sample average is 16,5 %for dry concrete with pipes valves and 15,54 % for methods pipe without valve. Cement loses value the average per sample is 29% to methods of pipe valves and 31% for pipes without valves. Pattern collapse of the specimen on the waterlogged peat areas due to the binding material that is not perfect

    CONCEPTUAL DESIGN OF BOMB DETECTOR AS ANTICIPATION OF TERRORISM THREAT TO PUBLIC SERVICES

    Get PDF
    Acts of terrorism are crimes and serious violations of human rights, also the threat of violence that can cause mass casualties and destruction of vital strategic objects. This is an urgent threat that needs to be prepared by designing a bomb detector conceptual design as anticipation of the threat of terrorism in public services. This study aims to obtain operational requirements and conceptual design of bomb detectors as detection of terrorism threats in public services. This study uses a mixed-method with a systems engineering approach and a life cycle model to produce a technological design. The results of operational requirements are sensors, standards, artificial intelligence, integration capability, reliability, calibration mode, portable, and easy to maintain. The configuration design is divided into three stages, namely, 1) sensors including a camera security surveillance system vector image, metal detectors, explosive detectors, and A-jamming; 2) as a processing device, processes an order with the help of an artificial intelligence system; and 3)  a security computer (surveillance), early warning, and mobile information to provide information to related agencies, especially the anti-terror unit

    Pengaruh Variasi Pengurangan Air dalam Campuran Beton Fc' 25 Mpa pada Pembuatan Beton Scc dengan Penambahan1% Sikament Ln

    Get PDF
    Dalam pembuatan benda uji metode yang digunakan yaitu Metode SNI, dengan kuat tekan rencana 25 MPa. Semen yang digunakan adalah semen PCC. Benda uji yang dibuat berbentuk silinder dengan Æ 15 cm, dan tinggi 30 cm. Terdapat lima variasi sampel beton yaitu beton +sikament ln 1% -air 0%, beton +sikament ln 1% -air 5%, beton +sikament ln 1% -air 10%, beton +sikament ln 1% -air 15%, dan beton +sikament ln 1% -air 20%. Pengujian/pengetesan benda uji meliputi uji kuat tekan, uji tarik belah, dan uji modulus elastisitas. Dari hasil penelitian nilai kuat tekan karakteristik beton normal dan beton +sikament ln 1% -air 0%, 5%, 10%, 15%, dan 20% pada umur 28 hari, masing-masing menghasilkan kuat tekan karakteristik beton 33,19 MPa, 31,32 MPa, 26,97 MPa, 28,04 MPa, 37,30 MPa, dan 40,05 MPa. Kuat tarik belah rata-rata beton normal danbeton +sikament ln 1% -air 0%, 5%, 10%, 15%, dan 20% adalah 3,28 MPa, 4,05 MPa, 4,15 MPa, 4,41 MPa, 3,93 MPa, 4,19 MPa. Modulus Elastisitas rata-rata beton normal dan beton +sikament ln 1% -air 0%, 5%, 10%, 15%, dan 20% adalah 21715,142 MPa, 24199,677 MPa, 23506,673 MPa, 21680,005 MPa, 20626,130 MPa, 28326,195 MPa. Dapat disimpulkan bahwa pengurangan air pada penggunaan sikament ln dapat meningkatkan kuat tekan karakteristik beton

    Studi Penggunaan Cangkang Kerang sebagai Pengganti Agregat Halus pada Mortar

    Get PDF
    Dalam pembuatan benda uji metode yang digunakan yaitu Metode SNI, dengan kuat tekan rencana K-175. Semen yang digunakan adalah semen PCC. Benda uji yang dibuat berbentuk kubus 5x5x5 cm. Pengujianbenda uji meliputi uji kuat tekan,uji modulus elastisitas, dan uji permeabilitas. Dari hasil penelitian cangkang kerang dapat digunakan sebagai alternatif agragat halus pada mortar. Kekuatan tekan karakteristik mortar normal sebesar 366,48 kg/cm2. Peningkatan kuat tekan karakteristik umur 28 hari terjadi pada persentase cangkang 15% (CK-15) sebesar 426,48 kg/cm2, persentase cangkang 30% (CK-30) sebesar 405,98 kg/cm2, persentase cangkang 45% (CK-45) sebesar 388,32 kg/cm2, dan persentase cangkang 75% (CK-75) sebesar 380,19 kg/cm2. Sedangkan pada persentase cangkang 100% (CK-100) terjadi penurunan kuat tekan karakteristik sebesar 312,66 kg/cm2. Subtitusi cangkang kerang yang paling baik adalah subtitusi pasir dengan cangkang kerang sebesar 15% (CK-15). Modulus elastisitas(Ec) mortar normal sebesar 20996,396 MPa untuk CK-15 sebesar 23386,258 MPa, untuk CK-30 sebesar 22333,293 MPa, untuk CK-45 sebesar 22862,203 MPa, untuk CK-75 sebesar 22357,835 MPa dan untuk CK-100 sebesar 21378,975 MPa. Dari hasil percobaan permeabilitas diperoleh koefesien permeabilitas rata-rata mortar normal sebesar 3,05574 Ă— 10-8. Pada percobaan koefesien permeabilitas cangkang kerang dengan subtitusi 15% (CK-15) terjadi kenaikan sebesar 1,8807 Ă— 10-8, pada percobaan koefesien permeabilitas cangkang kerang dengan subtitusi 30% (CK-30) terjadi kenaikan sebesar 1,26127 Ă— 10-8, pada percobaan koefesien permeabilitas cangkang kerang dengan subtitusi 45% (CK-45) terjadi kenaikan sebesar 1,4587 Ă— 10-8, pada percobaan koefesien permeabilitas cangkang kerang dengan subtitusi 75% (CK-75) terjadi kenaikan sebesar 1,12029 Ă— 10-8, dan pada percobaan koefesien permeabilitas cangkang kerang dengan subtitusi 100% (CK-100) terjadi kenaikan sebesar 1,944448 Ă— 10-8. Terjadi kenaikan koefesien permeabilitas terhadap mortar normal. Dapat disimpulkan bahwa penambahan cangkang kerang ini memberikan dampak positif terhadap permeabilitas mortar
    corecore