690 research outputs found
Sustainable clothing: challenges, barriers and interventions for encouraging more sustainable consumer behaviour
Research with consumers has revealed limited awareness of the sustainability impact of clothing (Goworek et al., 2012). Semi-structured interviews conducted with a range of experts in sustainable clothing to increase understanding of the challenges for sustainable clothing revealed that a focus on sustainability alone will not drive the necessary changes in consumers’ clothing purchase, care and disposal behaviour for three reasons: (i) clothing sustainability is too complex; (ii) consumers are too diverse in their ethical concerns; and (iii) clothing is not an altruistic purchase. The findings identify the challenges that need to be addressed and the associated barriers for sustainable clothing. Interventions targeting consumers, suppliers, buyers and retailers are proposed that encourage more sustainable clothing production, purchase, care and disposal behaviour. These interventions range from normalising the design of sustainable clothing and increasing the ease of purchase, to shifting clothes washing norms and increasing upcycling, recycling and repair
Assessment of Artifacts and Reproducibility across Spectral- and Time-Domain Optical Coherence Tomography Devices
Purpose
To report the frequency of optical coherence tomography (OCT) scan artifacts and to compare macular thickness measurements, interscan reproducibility, and interdevice agreeability across 3 spectral-domain (SD) OCT (also known as Fourier domain; Cirrus HD-OCT, RTVue-100, and Topcon 3D-OCT 1000) devices and 1 time-domain (TD) OCT (Stratus OCT) device.
Design
Prospective, noncomparative, noninterventional case series.
Participants
Fifty-two patients seen at the New England Eye Center, Tufts Medical Center Retina Service, between February and August 2008.
Methods
Two scans were performed for each of the SD OCT protocols: Cirrus macular cube 512×128 (software version 3.0; Carl Zeiss Meditec, Inc., Dublin, CA), RTVue (E)MM5 and MM6 (software version 3.5; Optovue, Inc., Fremont, CA), Topcon 3D Macular and Radial (software version 2.12; Topcon, Inc., Paramus, NJ), in addition to 1 TD OCT scan via Stratus macular thickness protocol (software version 4.0; Carl Zeiss Meditec, Inc.). Scans were inspected for 6 types of OCT scan artifacts and were analyzed. Interscan reproducibility and interdevice agreeability were assessed by intraclass correlation coefficients (ICCs) and Bland-Altman plots, respectively.
Main Outcome Measures
Optical coherence tomography image artifacts, macular thickness, reproducibility, and agreeability.
Results
Time-domain OCT scans contained a significantly higher percentage of clinically significant improper central foveal thickness (IFT) after manual correction (11-μm change or more) compared with SD OCT scans. Cirrus HD-OCT had a significantly lower percentage of clinically significant IFT (11.1%) compared with the other SD OCT devices (Topcon 3D, 20.4%; Topcon Radial, 29.6%; RTVue (E)MM5, 42.6%; RTVue MM6, 24.1%; P = 0.001). All 3 SD OCT devices had central foveal subfield thicknesses that were significantly more than that of TD OCT after manual correction (P<0.0001). All 3 SD OCT devices demonstrated a high degree of reproducibility in the central foveal region (ICCs, 0.92–0.97). Bland-Altman plots showed low agreeability between TD and SD OCT scans.
Conclusions
Out of all OCT devices analyzed, cirrus HD-OCT scans exhibited the lowest occurrence of any artifacts (68.5%), IFT (40.7%), and clinically significant IFT (11.1%), whereas Stratus OCT scans exhibited the highest occurrence of clinically significant IFT. Further work on improving segmentation algorithm to decrease artifacts is warranted.Research to Prevent Blindness, Inc. (United States) (Challenge Grant)National Institutes of Health (U.S.) (Grant R01-EY11289-23)National Institutes of Health (U.S.) (Grant R01-EY13178-07)National Institutes of Health (U.S.) (Grant P30-EY008098)United States. Air Force Office of Scientific Research (Grant FA9550-07-1-0101)United States. Air Force Office of Scientific Research (Grant FA9550-07-1-0014
Atlas of Maine: Seabird Habitat in the Acadia Region
This map shows the distribution of critical habitat for inland wading birds and water fowl, and for the endangered roseate tern. It also highlights islands around Acadia which sea birds rely on for nesting habitat. Mapping these sites is critical to creating conservation plans for bird species in the Acadia region.
This map was projected using the NAD 1983 datum and the UTM zone 19 N coordinate system. Data was sourced from the Maine Office of GIS (www.maine.gov/megis)
Distribution of Farmers\u27 Markets Accepting SNAP in Maine
Maine’s SNAP farmers’ market program allows low-income families to use their EBT (Electronic Benefits Transfer) cards to pay for fresh produce at select farmers’ markets, often at a discounted rate. However, currently only about 30% of farmers’ markets in Maine accommodate SNAP. It is unclear whether these SNAP farmers’ markets are distributed in the areas that need them most.
In this study I examine the distribution of farmers’ markets that currently accept SNAP/EBT cards and compare them to a). the number of individuals in the town which received food supplements in 2015. b). the town’s population as of 2010 and c). the percentage of the town’s population which receives food supplements. Based on this analysis I hope to identify some factors which influence the distribution of SNAP farmers’ markets, and identify areas that would benefit most from the SNAP program
Turn of the Century Irish Catholics in St. Malachi\u27s Parish
Kathleen Sull discusses St. Malachi’s Parish, which served as “the spiritual, social, and educational center” for Irish immigrants and their families in Cleveland’s “Angle” neighborhood from 1880 to 1920. Abstract; originally published in Western Reserve Studies Symposium (9th:1994 : Cleveland, Ohio
Confidentiality, anonymity and amnesty for midwives in distress seeking online support – Ethical?
BACKGROUND: Midwife health is intrinsically linked to the quality of safe patient care. To ensure safe patient care, there is a need to deliver emotional support to midwives. One option that midwives may turn to may be a confidential online intervention, instead of localised, face-to-face support. RESEARCH DESIGN: Following the Realist And MEta-narrative Evidence Syntheses: Evolving Standards publication standards, this realist synthesis approach explores the ethical considerations in permitting confidentiality, anonymity and amnesty in online interventions to support midwives in work-related psychological distress. An iterative search methodology was used to select nine papers for review. To assimilate information, papers were examined for ideas relating to ethical dimensions of online interventions to support midwives in work-related psychological distress. This review takes a narrative approach. FINDINGS: Online interventions can support the development of insight, help seeking and open discussion. Additionally, Internet support groups can become morally persuasive in nature. Anonymity and confidentiality are both effective and therapeutic features of online interventions when used in collaboration with effective online moderation. Yet, ethical dilemmas remain where users cannot be identified. DISCUSSION: Confidentiality and anonymity remain key components of successful online interventions. However, sanctioning the corollary component of amnesty may provoke moral discomfort for those seeking immediate accountability. For others, amnesty is seen as essential for open disclosure and help seeking. Ultimately, the needs of midwives must be balanced with the requirement to protect the public and the professional reputation of midwifery. CONCLUSION: In supporting midwives online, the principles of anonymity, confidentiality and amnesty may evoke some resistance on ethical grounds. However, without offering identity protection, it may not be possible to create effective online support services for midwives. The authors of this article argue that the principles of confidentiality, anonymity and amnesty should be upheld in the pursuit of the greatest benefit for the greatest number of people
Functional compensation of glutathione S-transferase M1 (GSTM1) null by another GST superfamily member,GSTM2
The gene for glutathione-S-transferase (GST) M1 (GSTM1), a member of the GST-superfamily, is widely studied in cancer risk with regard to the homozygous deletion of the gene (GSTM1 null), leading to a lack of corresponding enzymatic activity. Many of these studies have reported inconsistent findings regarding its association with cancer risk. Therefore, we employed in silico, in vitro, and in vivo approaches to investigate whether the absence of a functional GSTM1 enzyme in a null variant can be compensated for by other family members. Through the in silico approach, we identified maximum structural homology between GSTM1 and GSTM2. Total plasma GST enzymatic activity was similar in recruited individuals, irrespective of their GSTM1 genotype (positive/null). Furthermore, expression profiling using real-time PCR, western blotting,
and GSTM2 overexpression following transient knockdown of GSTM1 in HeLa cells confirmed that the absence of GSTM1 activity can be compensated for by the overexpression of GSTM
The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
BACKGROUND: To investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT). METHODS: 10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovascular age-related macular degeneration (AMD) were examined with RTVue SD-OCT. The MM5 protocol was used in two consecutive sessions to scan the macula. For the first session, the device was set 3.5 cm from the eye in order to obtain detectable signal with low fundus image quality (suboptimal setting) while in the second session a distance of 2.5 cm was set with a good quality fundus image. The signal strength (SSI) value was recorded. The score for retinal boundary detection errors (RBDE) was calculated for ten scans of each examination. RBDE scores were recorded for the whole scan and also for the peripheral 1.0 mm region. RBDE scores, regional retinal thickness values and SSI values between the two sessions were compared. The correlation between SSI and the number of RBDEs was also examined. RESULTS: The SSI was significantly lower with suboptimal settings compared to optimal settings (63.9+/-12.0 vs. 68.3+/-12.2, respectively, p = 0.001) and the number of RBDEs was significantly higher with suboptimal settings in the "all-eyes" group along with the group of healthy subjects and eyes with DME (9.1+/-6.5 vs. 6.8+/-6.3, p = 0.007; 4.4+/-2.6 vs. 2.5+/-1.6, p = 0.035 and 9.7+/-3.3 vs. 5.1+/-3.7, p = 0.008, respectively). For these groups, significant negative correlation was found between the SSI and the number of RBDEs. In the AMD group, the number of RBDEs was markedly higher compared to the other groups and there was no difference in RBDEs between optimal and suboptimal settings with the errors being independent of the SSI. There were significantly less peripheral RBDEs with optimal settings in the "all-eyes" group and the DME subgroup (2.7+/-2.6 vs. 4.2+/-2.8, p = 0.001 and 1.4+/-1.7 vs. 4.1+/-2.2, p = 0.007, respectively). Retinal thickness in the two settings was significantly different only in the outer-superior region in DME. CONCLUSIONS: Optimal distance settings improve SD-OCT SSI with a decrease in RBDEs while retinal thickness measurements are independent of scanning distance
- …
