266 research outputs found

    Creating and Certifying the Professional Mediator -- Education and Credentialing

    Get PDF
    Existing and pending law school mediation programs, post-graduate mediator training programs, mentorship programs, credentialing movements, and continuing mediation education were examined by a panel and speakers directly involved in those fields. Are we effectively training new mediators in law schools and post-graduate programs? Should we, and how can we, credential mediators? Do good mediators need to be re-trained? How would continuing mediation educational requirements be implemented

    Cutting errors in total knee replacement: Assessment by computer assisted surgery

    Get PDF
    The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in 40 consecutive total knee replacements was reported. All the operations were done by the same surgeon. The amount of cutting error was measured by the use of computer navigation system. It was hypothesized that there was no difference in the amount of error between bone cut through the cutting slot (slotted cutting) and bone cut done on the surface of the cutting guide (open cutting). It was found that the average absolute cutting error was 1° in the coronal plane and 1.4° in the sagittal plane. Significantly more outlier (more than 3°) was observed in the errors in the sagittal plane (P = 0.014, chi square test). Open cutting resulted in less error in the sagittal plane of the tibial cut when compared with slotted cutting (P = 0.031, Mann-Whitney U Test). This was attributed by the use of a thicker saw blade with higher stiffness in the open cutting method. © 2008 Springer-Verlag.postprin

    Contemporary Tendencies in Mediation

    Get PDF
    Editors: Humberto dalla Bernardina de Pinho, Juliana Loss de AndradePresentation / Humberto Dalla Bernardina de Pinho, Juliana Loss de Andrade. -- Mediation in England / Neil Andrews. -- Un Reto para la Mediación: el Diseño de su Código Deontológico / Nuria Belloso Martín. -- Alternative Dispute Resolution and Aboriginal-Crown Reconciliation in Canada / Roshan Danesh, Jessica Dickson. -- A False ‘Prince Charming’ Keeps ‘Sleeping Beauty’ in a Coma: On Voluntary Mediation Being the True Oxymoron of Dispute Resolution Policy / Giuseppe De Palo. -- Programa de Derivación Judicial en Puerto Rico Desde la Perspectiva de la Mediación / Jacqueline N. Font-Guzmán. -- Mediation in Switzerland / Isabelle Hering. -- Reconocimiento y eficacia de los acuerdos de mediación mercantil internacional / Juliana Loss de Andrade. -- The Uses of Mediation / Lela P. Love, Joseph B. Stulberg. -- Multi-Dimensional Mediation / Paul E. Mason. -- “Italy Is Doing It – Should We Be?” Civil and Commercial Mediation in Italy / Giovanni Matteucci. -- Limites dos Meios Alternativos de Conflito / José Marinho Paulo Junior. -- New Perspectives of Civil and Commercial Mediation in Brazil / Humberto Dalla Bernardina de Pinho. -- Practical Impacts of Theoretical Lenses / Elton Simoes, Andrea Maia. -- Development and Resistance in South Europe Justice Systems to Restorative Justice / Helena Soleto Muño

    Small Stem Total Hip Arthroplasty in Hypoplasia of the Femur

    Get PDF
    Total hip arthroplasty in hypoplastic femurs is technically difficult and the incidence of complications and aseptic loosening is relatively high. Cemented, uncemented, off-the-shelf, and custom-made stems all have been advocated in these cases. From 1978 to 1997, we performed 86 total hip arthroplasties in 77 patients with a hypoplastic femur using a cemented, off-the-shelf, small, curved, cobalt-chromium stem. We hypothesized results equaled those of the identical but larger-sized stems in normal-sized femora which were used as comparisons. Clinical and radiographic evaluations were performed. Minimum followup was 4.2 years (mean, 12 years; range, 4.2–20.3 years); mean Harris hip score was 88, and mean hip flexion was 104°. Six stems were revised: four because of aseptic loosening, one after a femoral fracture, and one because of malpositioning. Complications included one perforation and one fracture of the femur, one fracture, one nonunion of the greater trochanter, and one deep infection. Implant survivorship for all hips at 15 years with aseptic revision of the stem as the end point was 90% (confidence interval, 82–99) which equaled results of the larger stems. The small off-the-shelf cemented Weber stem has a high long-term survival and a low complication rate. Survival compares favorably with other small-sized total hip systems

    The Impact of Contact Isolation on the Quality of Inpatient Hospital Care

    Get PDF
    Background: Contact Isolation is a common hospital infection prevention method that may improve infectious outcomes but may also hinder healthcare delivery. Methods: To evaluate the impact of Contact Isolation on compliance with individual and composite process of care quality measures, we formed four retrospective diagnosis-based cohorts from a 662-bed tertiary-care medical center. Each cohor

    Identification of Equid herpesvirus 2 in tissue-engineered equine tendon

    Get PDF
    Background: Incidental findings of virus-like particles were identified following electron microscopy of tissue-engineered tendon constructs (TETC) derived from equine tenocytes. We set out to determine the nature of these particles, as there are few studies which identify virus in tendons per se, and their presence could have implications for tissue-engineering using allogenic grafts. Methods: Virus particles were identified in electron microscopy of TETCs. Virion morphology was used to initially hypothesise the virus identity.  Next generation sequencing was implemented to identify the virus. A pan herpesvirus PCR was used to validate the RNASeq findings using an independent platform. Histological analysis and biochemical analysis was undertaken on the TETCs. Results: Morphological features suggested the virus to be either a retrovirus or herpesvirus. Subsequent next generation sequencing mapped reads to Equid herpesvirus 2 (EHV2). Histological examination and biochemical testing for collagen content revealed no significant differences between virally affected TETCs and non-affected TETCs. An independent set of equine superficial digital flexor tendon tissue (n=10) examined using designed primers for specific EHV2 contigs identified at sequencing were negative. These data suggest that EHV is resident in some equine tendon. Conclusions: EHV2 was demonstrated in equine tenocytes for the first time; likely from in vivo infection. The presence of EHV2 could have implications to both tissue-engineering and tendinopathy

    A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre.</p> <p>Methods</p> <p>A custom made neck jig device is presented as well as the results of a pilot study.</p> <p>The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned.</p> <p>Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation.</p> <p>Results</p> <p>The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9° and maximum distance between insertion points was 2.1 mm.</p> <p>Conclusions</p> <p>Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.</p

    International Preoperative Rectal Cancer Management: Staging, Neoadjuvant Treatment, and Impact of Multidisciplinary Teams

    Get PDF
    BACKGROUND: Little is known regarding variations in preoperative treatment and practice for rectal cancer (RC) on an international level, yet practice variation may result in differences in recurrence and survival rates. METHODS: One hundred seventy-three international colorectal centers were invited to participate in a survey of preoperative management of rectal cancer. RESULTS: One hundred twenty-three (71%) responded, with a majority of respondents from North America, Europe, and Asia. Ninety-three percent have more than 5 years' experience with rectal cancer surgery. Fifty-five percent use CT scan, 35% MRI, 29% ERUS, 12% digital rectal examination and 1% PET scan in all RC cases. Seventy-four percent consider threatened circumferential margin (CRM) an indication for neoadjuvant treatment. Ninety-two percent prefer 5-FU-based long-course neoadjuvant chemoradiation therapy (CRT). A significant difference in practice exists between the US and non-US surgeons: poor histological differentiation as an indication for CRT (25% vs. 7.0%, p = 0.008), CRT for stage II and III rectal cancer (92% vs. 43%, p = 0.0001), MRI for all RC patients (20% vs. 42%, p = 0.03), and ERUS for all RC patients (43% vs. 21%, p = 0.01). Multidisciplinary team meetings significantly influence decisions for MRI (RR = 3.62), neoadjuvant treatment (threatened CRM, RR = 5.67, stage II + III RR = 2.98), quality of pathology report (RR = 4.85), and sphincter-saving surgery (RR = 3.81). CONCLUSIONS: There was little consensus on staging, neoadjuvant treatment, and preoperative management of rectal cancer. Regular multidisciplinary team meetings influence decisions about neoadjuvant treatment and staging methods
    corecore