1,986 research outputs found

    Project management under uncertainty

    Get PDF
    Morris' (1986) analysis of the factors affecting project success and failure is considered in relation to the psychology of judgement under uncertainty. A model is proposed whereby project managers may identify the specific circumstances in which human decision-making is prone to systematic error, and hence may apply a number of de-biasing techniques

    An Examination of Backgrounds to Early-Run Minimum-Bias Events in ATLAS at the LHC

    Get PDF
    The initial parts of the Large Hadron Collider (LHC) run will be a source of critical information - about the ATLAS detector and about the physics of pppp collisions at sqrts=14sqrt{s} = 14 TeV, including parton distribution evolution and the cross-sections of sigmappsigma_{pp}. The accelerator itself will be the source of some detector interest, as we have a first look at what have so far been speculations on the quality of the vacuum in the experimental insertion, and the cleanliness of the beam from the accelerator. The shakedown period, with its low beam squeeze, low luminosity, and undemanding trigger menus, will be of great interest, avoiding the pileup and radiation levels that will arrive with higher luminosity -- making it an important opportunity to investigate minimum-bias events in relative isolation. For the short lifetime of the Minimum Bias Trigger Scintillators (MBTS), which are expected to fail within a few months of running, they will aid in discriminating the minimum bias signal of inelastic non-single-diffractive pppp collisions. Using single- or double-coincidence signatures, the MBTS system and other trigger and analysis strategies attempt to avoid triggering on otherwise empty bunch crossings and eliminate the effects of beam-gas collisions and beam-halo effects which would lead these spurious triggers that would reduce the general minimum-bias trigger efficiency. An examination of the effects of beam halo and beam -gas interactions on the minimum-bias trigger response is made. The signatures of the beam halo and beam gas are examined from the standard ATLAS tracking reconstruction

    Gophers and Moles

    Get PDF
    n/

    Design guide for high pressure oxygen systems

    Get PDF
    A repository for critical and important detailed design data and information, hitherto unpublished, along with significant data on oxygen reactivity phenomena with metallic and nonmetallic materials in moderate to very high pressure environments is documented. This data and information provide a ready and easy to use reference for the guidance of designers of propulsion, power, and life support systems for use in space flight. The document is also applicable to designs for industrial and civilian uses of high pressure oxygen systems. The information presented herein are derived from data and design practices involving oxygen usage at pressures ranging from about 20 psia to 8000 psia equal with thermal conditions ranging from room temperatures up to 500 F

    The effects of continuous positive airway pressure therapy withdrawal on cardiac repolarization: data from a randomized controlled trial†

    Get PDF
    Aims The preliminary evidence supports an association between obstructive sleep apnoea (OSA), disturbed cardiac repolarization, and consequent cardiac dysrhythmias. The aim of the current trial was to assess the effects of continuous positive airway pressure (CPAP) therapy withdrawal on the measures of cardiac repolarization in patients with OSA. Methods and results Forty-one OSA patients established on CPAP treatment were randomized to either CPAP withdrawal (subtherapeutic CPAP) or continue therapeutic CPAP for 2 weeks. Polysomnography was performed, and indices of cardiac repolarization (QTc, TpTec intervals) and dispersion of repolarization (TpTe/QT ratio) were derived from 12-lead electrocardiography (ECG) at baseline and 2 weeks. Continuous positive airway pressure withdrawal led to a recurrence of OSA. Compared with therapeutic CPAP, subtherapeutic CPAP for 2 weeks was associated with a significant increase in the length of the QTc and TpTec intervals (mean difference between groups 21.4 ms, 95% CI 11.3-1.6 ms, P < 0.001 and 14.4 ms, 95% CI 7.2-21.5 ms, P < 0.001, respectively) and in the TpTe/QT ratio (mean difference between groups 0.02, 95% CI 0.00-0.03, P = 0.020). There was a statistically significant correlation between the change in apnoea/hypopnoea index (AHI) from baseline, and both the change in the QTc interval and the TpTec interval (r = 0.60, 95% CI 0.36-0.77, P < 0.001 and r = 0.45, 95% CI 0.17-0.67, P = 0.003, n = 41, respectively). Conclusion Continuous positive airway pressure withdrawal is associated with the prolongation of the QTc and TpTec intervals and TpTe/QT ratio, which may provide a possible mechanistic link between OSA, cardiac dysrhythmias, and thus sudden cardiac deat

    MB 700 Anthropology for Christian Mission

    Get PDF
    Textbook: Cultural Anthropology: An Applied Perspective, fifth edition by Gary Ferraro Readings: Anthropology and Christian Mission: A Reader, Darrell Whiteman (ed.)Customs and Cultures by Eugene Nidahttps://place.asburyseminary.edu/syllabi/2521/thumbnail.jp

    High temperature GaAs X-ray detectors

    Get PDF
    Two GaAs p+-i-n+ mesa X-ray photodiodes were characterized for their electrical and photon counting X-ray spectroscopic performance over the temperature range of 100 °C to –20 °C. The devices had 10 μm thick i layers with different diameters: 200 μm (D1) and 400 μm (D2). The electrical characterization included dark current and capacitance measurements at internal electric field strengths of up to 50 kV/cm. The determined properties of the two devices were compared with previously reported results that were made with a view to informing the future development of photon counting X-ray spectrometers for harsh environments, e.g., X-ray fluorescence spectroscopy of planetary surfaces in high temperature environments. The best energy resolution obtained (Full Width at Half Maximum at 5.9 keV) decreased from 2.00 keV at 100 °C to 0.66 keV at –20 °C for the spectrometer with D1, and from 2.71 keV at 100 °C to 0.71 keV at –20 °C for the spectrometer with D2. Dielectric noise was found to be the dominant source of noise in the spectra, apart from at high temperatures and long shaping times, where the main source of photopeak broadening was found to be the white parallel noise

    A crossover randomised controlled trial of oral mandibular advancement devices for obstructive sleep apnoea-hypopnoea (TOMADO)

    Get PDF
    Rationale Mandibular advancement devices (MADs) are used to treat obstructive sleep apnoea-hypopnoea syndrome (OSAHS) but evidence is lacking regarding their clinical and cost-effectiveness in less severe disease. Objectives To compare clinical- and cost-effectiveness of a range of MADs against no treatment in mild to moderate OSAHS. Measurements and methods This open-label, randomised, controlled, crossover trial was undertaken at a UK sleep centre. Adults with Apnoea-Hypopnoea Index (AHI) 5–<30/h and Epworth Sleepiness Scale (ESS) score ≥9 underwent 6 weeks of treatment with three nonadjustable MADs: self-moulded (SleepPro 1; SP1); semi-bespoke (SleepPro 2; SP2); fully-bespoke MAD (bMAD); and 4 weeks no treatment. Primary outcome was AHI scored by a polysomnographer blinded to treatment. Secondary outcomes included ESS, quality of life, resource use and cost. Main results 90 patients were randomised and 83 were analysed. All devices reduced AHI compared with no treatment by 26% (95% CI 11% to 38%, p=0.001) for SP1, 33% (95% CI 24% to 41%) for SP2 and 36% (95% CI 24% to 45%, p<0.001) for bMAD. ESS was 1.51 (95% CI 0.73 to 2.29, p<0.001, SP1) to 2.37 (95% CI 1.53 to 3.22, p<0.001, bMAD) lower than no treatment (p<0.001 for all). Compliance was lower for SP1, which was the least preferred treatment at trial exit. All devices were cost-effective compared with no treatment at a £20 000/quality-adjusted life year (QALY) threshold. SP2 was the most cost-effective up to £39 800/QALY. Conclusions Non-adjustable MADs achieve clinically important improvements in mild to moderate OSAHS and are cost-effective
    • …
    corecore