199 research outputs found

    Simulation of the synergistic low Earth orbit effects of vacuum thermal cycling, vacuum UV radiation, and atomic oxygen

    Get PDF
    In order to assess the low Earth orbit (LEO) durability of candidate space materials, it is necessary to use ground laboratory facilities which provide LEO environmental effects. A facility combining vacuum thermal cycling and vacuum ultraviolet (VUV) radiation has been designed and constructed at NASA Lewis Research Center for this purpose. This facility can also be operated without the VUV lamps. An additional facility can be used to provide VUV exposure only. By utilizing these facilities, followed by atomic oxygen exposure in an RF plasma asher, the effects of the individual vacuum thermal cycling and VUV environments can be compared to the effect of the combined vacuum thermal cycling/VUV environment on the atomic oxygen durability of materials. The synergistic effects of simulated LEO environmental conditions on materials were evaluated by first exposing materials to vacuum thermal cycling, VUV, and vacuum thermal cycling/VUV environments followed by exposure to atomic oxygen in an RP plasma asher. Candidate space power materials such as atomic oxygen protected polyimides and solar concentrator mirrors were evaluated using these facilities. Characteristics of the Vacuum Thermal Cycling/VUV Exposure Facility which simulates the temperature sequences and solar ultraviolet radiation exposure that would be experienced by a spacecraft surface in LEO are discussed. Results of durability evaluations of some candidate space power materials to the simulated LEO environmental conditions will also be discussed. Such results have indicated that for some materials, atomic oxygen durability is affected by previous exposure to thermal cycling and/or VUV exposure

    Atomic Oxygen Durability Evaluation of Protected Polymers Using Thermal Energy Plasma Systems

    Get PDF
    The durability evaluation of protected polymers intended for use in low Earth orbit (LEO) has necessitated the use of large-area, high-fluence, atomic oxygen exposure systems. Two thermal energy atomic oxygen exposure systems which are frequently used for such evaluations are radio frequency (RF) plasma ashers and electron cyclotron resonance plasma sources. Plasma source testing practices such as ample preparation, effective fluence prediction, atomic oxygen flux determination, erosion measurement, operational considerations, and erosion yield measurements are presented. Issues which influence the prediction of in-space durability based on ground laboratory thermal energy plasma system testing are also addressed

    Sources of Sex Information Used by Young British Women Who Have Sex with Women (WSW) and Women Who Have Sex Exclusively with Men (WSEM): Evidence from the National Survey of Sexual Attitudes and Lifestyles

    Get PDF
    There is little consideration about the provision of information about sex to women who have sex with women (WSW). This study drew on data from the third National Survey of Sexual Attitudes and Lifestyle, a nationally representative survey of people in Great Britain. Logistic regression was undertaken to examine firstly the relationships between WSW and women who have sex exclusively with men (WSEM) and their main source of information about sex, and secondly between WSW/WSEM and unmet need for information about sex. Each source was included as the binary outcome indicating yes this was the main source, or no this was not the main source of information about sex. The results found that WSW had significantly lower odds of reporting lessons at schools as their main source of information, and significantly higher odds of reporting sources defined as ‘other’ (predominantly first girlfriend/boyfriend or sexual partner) as their main source of information. Reported levels of unmet need for information was also higher amongst young WSW compared with WSEM. This study provides new insights into the sex educational needs of young women and highlights the need for sex education in schools in Great Britain to include information on a full-range of sexual practices, including same-sex sexual relationships

    Atomic oxygen durability evaluation of the flexible batten for the photovoltaic array mast on Space Station

    Get PDF
    A test program was conducted at the National Aeronautics and Space Administration's Lewis Research Center (LeRC) to evaluate the long term low Earth orbital (LEO) atomic oxygen (AO) durability of a flexible (fiberglass-epoxy composite) batten. The flexible batten is a component used to provide structural rigidity in the photovoltaic array mast on Space Station. The mast is used to support and articulate the photovoltaic array, therefore, the flexible batten must be preloaded for the 15 year lifetime of an array blanket. Development hardware and composite materials were evaluated in ground testing facilities for AO durability and dynamic retraction-deployment cyclic loading representative of expected full life in-space application. The CV1144 silicone (AO protective) coating was determined to provide adequate protection against AO degradation of the composite material and provided fiber containment, thus the structural integrity of the flexible batten was maintained. Both silicone coated and uncoated flexible battens maintained load carrying capabilities. Results of the testing did indicate that the CV1144 silicone protective coating was oxidized by AO reactions to form a brittle glassy (SiO2) skin that formed cracking patterns on all sides of the coated samples. The cracking was observed in samples that were mechanically stressed as well as samples in non-stressed conditions. The oxidized silicon was observed to randomly spall in small localized areas, on the flexible battens that underwent retraction-deployment cycling. Some darkening of the silicon, attributed to vacuum ultraviolet (VUV) radiation, was observed

    Adherence to Daily Weights and Total Fluid Orders in the Pediatric Intensive Care Unit

    Get PDF
    Background: Fluid is central to the resuscitation of critically ill children. However, many pay limited attention to continued fluid accumulation. Fluid overload (FO) is associated with significant morbidity and mortality. The Volume Status Awareness Program (VSAP) is a multi-phase quality improvement initiative aimed at reducing iatrogenic FO. For baseline data, the authors examined a retrospective cohort of patients admitted to the pediatric intensive care unit. Methods: Cohort included diuretic-naive patients admitted to the pediatric intensive care unit at a tertiary care children's hospital in 2014. Furosemide-exposure was used to indicate provider-perceived FO. Variables included daily weight and total fluid (TF) orders, and their timing, frequency, and adherence. Implementation of VSAP phase 1 (bundle of interventions to promote consistent use of patient weights) occurred in June 2017. Results: Forty-nine patients met criteria. Five (10%) had daily weight orders, and 41 (84%) had TF orders-although 7 of these orders followed furosemide administration. Adherence to TF orders was good with 32 (78%) patients exceeding TF limits by 5% FO by day 1, and 22 (51%) had > 10% cumulative FO by day 3. Following phase 1 of the VSAP, the frequency of daily weight orders increased from 6% to 88%. Conclusions: In our institution, use of fluid monitoring tools is both inconsistent and infrequent. Early data from the VSAP project suggests simple interventions can modify ordering and monitoring practice, but future improvement cycles are necessary to determine if these changes are successful in reducing iatrogenic FO

    Client Participation in Moral Case Deliberation: A Precarious Relational Balance

    Get PDF
    Moral case deliberation (MCD) is a form of clinical ethics support in which the ethicist as facilitator aims at supporting professionals with a structured moral inquiry into their moral issues from practice. Cases often affect clients, however, their inclusion in MCD is not common. Client participation often raises questions concerning conditions for equal collaboration and good dialogue. Despite these questions, there is little empirical research regarding client participation in clinical ethics support in general and in MCD in particular. This article aims at describing the experiences and processes of two MCD groups with client participation in a mental healthcare institution. A responsive evaluation was conducted examining stakeholders’ issues concerning client participation. Findings demonstrate that participation initially creates uneasiness. As routine builds up and client participants meet certain criteria, both clients and professionals start thinking beyond ‘us-them’ distinctions, and become more equal partners in dialogue. Still, sentiments of distrust and feelings of not being safe may reoccur. Client participation in MCD thus requires continuous reflection and alertness on relational dynamics and the quality of and conditions for dialogue. Participation puts the essentials of MCD (i.e., dialogue) to the test. Yet, the methodology and features of MCD offer an appropriate platform to introduce client participation in healthcare institutions
    corecore