2,725 research outputs found

    Rating assignments: Lessons from international banks

    Get PDF
    This paper estimates ordered logit and probit regression models for bank ratings which also include a country index to capture country-specific variation. The empirical findings provide support to the hypothesis that the individual international bank ratings assigned by Fitch Ratings are underpinned by fundamental quantitative financial analyses. Also, there is strong evidence of a country effect. Our model is shown to provide accurate predictions of bank ratings for the period prior to the 2007 – 2008 banking crisis based upon publicly available information. However, our results also suggest that quantitative models are not likely to be able to predict ratings with complete accuracy. Furthermore, we find that both quantitative models and rating agencies are likely to produce highly inaccurate predictions of ratings during periods of financial instability

    Neutron polarisation analysis of Polymer: Fullerene blends for organic photovoltaics

    Get PDF
    The photogeneration process in polymer-fullerene organic solar cells relies strongly on the nanostructure and on the nano/picosecond dynamics occurring in these complex blends. Elastic and inelastic neutron scattering techniques are valuable tools with which to investigate those features in the appropriate time and space domains. In particular, quasi-elastic neutron scattering (QENS) connects useful structural and dynamical information by the measurement of dynamical incoherent (single particle) fluctuations in soft materials as a function of lengthscale. Extraction of these fluctuation rates can, however, be hampered by the presence of coherent contributions, originating from elastic scattering, and/or inelastic scattering modes which overlap in the space/time domain with the incoherent single-particle motions. As we have already seen in a previous study [1], this happens in poly(3-hexylthiophene) (P3HT) and [6,6]-Phenyl C61 butyric acid methyl ester (PCBM) solid blends, in which the coherent contribution arising from the PCBM crystalline phase seems to affect the interpretation of the polymer dynamics. Here, we utilise neutron polarisation analysis as an effective tool to separate coherent and incoherent contributions and make QENS data analysis of these blends more reliable

    Traumatic brain injury: Age at injury influences dementia risk after TBI

    Get PDF
    Traumatic brain injury (TBI) is increasingly recognized as a risk factor for dementia. New data provide further support for this association and demonstrate the influence of age at injury and injury severity on dementia risk after TBI, revealing that even mild TBI increases dementia risk in those aged ≄65 years

    Abnormal loading and functional deficits are present in both limbs before and after unilateral knee arthroplasty

    Get PDF
    Abstract Unilateral knee replacement is often followed by a contralateral replacement in time and the biomechanics of the other knee before and after knee replacement remains poorly understood. The aim of this paper is to distinguish the features of arthritic gait in the affected and unaffected legs relative to a normal population and to assess the objective recovery of gait function post-operatively, with the aim of defining patients at risk of poor post-operative function. Twenty patients with severe knee OA but no pain or deformity in any other lower limb joint were compared to twenty healthy subjects of the same age. Gait analysis was performed and quadriceps and hamstrings co-contraction was measured. Fifteen subjects returned 1 year following knee arthroplasty. Moments and impulses were calculated, principal component analysis was used to analyse the waveforms and a classification technique (the Cardiff Classifier) was used to select the most discriminant data and define functional performance. Comparing pre-operative function to healthy function, classification accuracies for the affected and unaffected knees were 95% and 92.5% respectively. Post-operatively, the affected limb returned to the normal half of the classifier in 8 patients, and 7 of those patients returned to normal function in the unaffected limb. Recovery of normal gait could be correctly predicted 13 out of 15 times at the affected knee, and 12 out of 15 times at the unaffected knee based on pre-operative gait function. Focused rehabilitation prior to surgery may be beneficial to optimise outcomes and protect the other joints following knee arthroplasty

    Extending work tolerance time in the heat in protective ensembles with pre- and per-cooling methods

    Get PDF
    © 2020 Elsevier Ltd Objectives: Investigate whether a range of cooling methods can extend tolerance time and/or reduce physiological strain in those working in the heat dressed in a Class 2 chemical, biological, radiological, nuclear (CBRN) protective ensemble. Methods: Eight males wore a Class 2 CBRN ensemble and walked for a maximum of 120 min at 35 °C, 50% relative humidity. In a randomised order, participants completed the trial with no cooling and four cooling protocols: 1) ice-based cooling vest (IV), 2) a non-ice-based cooling vest (PCM), 3) ice slushy consumed before work, combined with IV (SLIV) and 4) a portable battery-operated water-perfused suit (WPS). Mean with 95% confidence intervals are presented. Results: Tolerance time was extended in PCM (46 [36, 56] min, P = 0.018), SLIV (56 [46, 67] min, P < 0.001) and WPS (62 [53, 70] min, P < 0.001), compared with control (39 [30, 48] min). Tolerance time was longer in SLIV and WPS compared with both IV (48 [39, 58 min]) and PCM (P ≀ 0.011). After 20 min of work, HR was lower in SLIV (121 [105, 136] beats·min−1), WPS (117 [101, 133] beats·min−1) and IV (130 [116, 143] beats·min−1) compared with control (137 [120, 155] beats·min−1) (all P < 0.001). PCM (133 [116, 151] beats·min−1) did not differ from control. Conclusion: All cooling methods, except PCM, utilised in the present study reduced cardiovascular strain, while SLIV and WPS are most likely to extend tolerance time for those working in the heat dressed in a Class 2 CBRN ensemble.This project is financially supported by the United States Government through the United States Department of Defense (DOD).Accepted versio

    A Snapshot of J. L. Synge

    Full text link
    A brief description is given of the life and influence on relativity theory of Professor J. L. Synge accompanied by some technical examples to illustrate his style of work

    Observation of pseudogap behavior in a strongly interacting Fermi gas

    Full text link
    Ultracold atomic Fermi gases present an opportunity to study strongly interacting Fermi systems in a controlled and uncomplicated setting. The ability to tune attractive interactions has led to the discovery of superfluidity in these systems with an extremely high transition temperature, near T/T_F = 0.2. This superfluidity is the electrically neutral analog of superconductivity; however, superfluidity in atomic Fermi gases occurs in the limit of strong interactions and defies a conventional BCS description. For these strong interactions, it is predicted that the onset of pairing and superfluidity can occur at different temperatures. This gives rise to a pseudogap region where, for a range of temperatures, the system retains some of the characteristics of the superfluid phase, such as a BCS-like dispersion and a partially gapped density of states, but does not exhibit superfluidity. By making two independent measurements: the direct observation of pair condensation in momentum space and a measurement of the single-particle spectral function using an analog to photoemission spectroscopy, we directly probe the pseudogap phase. Our measurements reveal a BCS-like dispersion with back-bending near the Fermi wave vector k_F that persists well above the transition temperature for pair condensation

    Internal and external cooling methods and their effect on body temperature, thermal perception and dexterity

    Get PDF
    © 2018 The Authors. Published by PLOS. This is an open access article available under a Creative Commons licence. The published version can be accessed at the following link on the publisher’s website: https://doi.org/10.1371/journal.pone.0191416© 2018 Maley et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Objective The present study aimed to compare a range of cooling methods possibly utilised by occupational workers, focusing on their effect on body temperature, perception and manual dexterity. Methods Ten male participants completed eight trials involving 30 min of seated rest followed by 30 min of cooling or control of no cooling (CON) (34C, 58% relative humidity). The cooling methods utilised were: ice cooling vest (CV0), phase change cooling vest melting at 14C (CV14), evaporative cooling vest (CVEV), arm immersion in 10C water (AI), portable water-perfused suit (WPS), heliox inhalation (HE) and ice slushy ingestion (SL). Immediately before and after cooling, participants were assessed for fine (Purdue pegboard task) and gross (grip and pinch strength) manual dexterity. Rectal and skin temperature, as well as thermal sensation and comfort, were monitored throughout. Results Compared with CON, SL was the only method to reduce rectal temperature (P = 0.012). All externally applied cooling methods reduced skin temperature (P0.05). Conclusion The present study observed that ice ingestion or ice applied to the skin produced the greatest effect on rectal and skin temperature, respectively. AI should not be utilised if workers require subsequent fine manual dexterity. These results will help inform future studies investigating appropriate pre-cooling methods for the occupational worker.This project is financially supported by the US Government through the Technical Support Working Group within the Combating Terrorism Technical Support Office.Published versio
    • 

    corecore