138 research outputs found

    Acoustic Emission from Plastic Deformation

    Get PDF
    I would like to discuss some recent work at the University of Denver concerning acoustic emission generated during plastic deformation. I must emphasize that this is a preliminary progress report and that the investigation is still in its early stages. I would like to acknowledge two people who have been working with me on this investigation, Robert Wittman of the Denver Research Institute and Frank Higgins, a graduate student of mine at the University of Denver

    AVIRIS ground data-processing system

    Get PDF
    The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been under development at JPL for the past four years. During this time, a dedicated ground data-processing system has been designed and implemented to store and process the large amounts of data expected. This paper reviews the objectives of this ground data-processing system and describes the hardware. An outline of the data flow through the system is given, and the software and incorporated algorithms developed specifically for the systematic processing of AVIRIS data are described

    Prolonged Effect of Omeprazole on the 14 C-Urea Breath Test

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73649/1/j.1572-0241.1996.tb08294.x.pd

    Assessing the Cost of Global Biodiversity and Conservation Knowledge

    Get PDF
    Knowledge products comprise assessments of authoritative information supported by standards, governance, quality control, data, tools, and capacity building mechanisms. Considerable resources are dedicated to developing and maintaining knowledge products for biodiversity conservation, and they are widely used to inform policy and advise decision makers and practitioners. However, the financial cost of delivering this information is largely undocumented. We evaluated the costs and funding sources for developing and maintaining four global biodiversity and conservation knowledge products: The IUCN Red List of Threatened Species, the IUCN Red List of Ecosystems, Protected Planet, and the World Database of Key Biodiversity Areas. These are secondary data sets, built on primary data collected by extensive networks of expert contributors worldwide. We estimate that US160million(range:US160 million (range: US116–204 million), plus 293 person-years of volunteer time (range: 278–308 person-years) valued at US14million(rangeUS 14 million (range US12–16 million), were invested in these four knowledge products between 1979 and 2013. More than half of this financing was provided through philanthropy, and nearly three-quarters was spent on personnel costs. The estimated annual cost of maintaining data and platforms for three of these knowledge products (excluding the IUCN Red List of Ecosystems for which annual costs were not possible to estimate for 2013) is US6.5millionintotal(range:US6.5 million in total (range: US6.2–6.7 million). We estimated that an additional US114millionwillbeneededtoreachpredefinedbaselinesofdatacoverageforallthefourknowledgeproducts,andthatonceachieved,annualmaintenancecostswillbeapproximatelyUS114 million will be needed to reach pre-defined baselines of data coverage for all the four knowledge products, and that once achieved, annual maintenance costs will be approximately US12 million. These costs are much lower than those to maintain many other, similarly important, global knowledge products. Ensuring that biodiversity and conservation knowledge products are sufficiently up to date, comprehensive and accurate is fundamental to inform decision-making for biodiversity conservation and sustainable development. Thus, the development and implementation of plans for sustainable long-term financing for them is critical

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data

    Quantifying the potential for bluetongue virus transmission in Danish cattle farms

    Get PDF
    We used a mechanistic transmission model to estimate the number of infectious bites (IBs) generated per bluetongue virus (BTV) infected host (cattle) using estimated hourly microclimatic temperatures at 22,004 Danish cattle farms for the period 2000–2016, and Culicoides midge abundance based on 1,453 light-trap collections during 2007–2016. We used a range of published estimates of the duration of the hosts’ infectious period and equations for the relationship between temperature and four key transmission parameters: extrinsic incubation period, daily vector survival rate, daily vector biting rate and host-to-vector transmission rate resulting in 147,456 combinations of daily IBs. More than 82% combinations of the parameter values predicted > 1 IBs per host. The mean IBs (10–90th percentiles) for BTV per infectious host were 59 (0–73) during the transmission period. We estimated a maximum of 14,954 IBs per infectious host at some farms, while a best-case scenario suggested transmission was never possible at some farms. The use of different equations for the vector survival rate and host-to-vector transmission rates resulted in large uncertainty in the predictions. If BTV is introduced in Denmark, local transmission is very likely to occur. Vectors infected as late as mid-September (early autumn) can successfully transmit BTV to a new host until mid-November (late autumn)

    Protein-enriched meal replacements do not adversely affect liver, kidney or bone density: an outpatient randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is concern that recommending protein-enriched meal replacements as part of a weight management program could lead to changes in biomarkers of liver or renal function and reductions in bone density. This study was designed as a placebo-controlled clinical trial utilizing two isocaloric meal plans utilizing either a high protein-enriched (HP) or a standard protein (SP) meal replacement in an outpatient weight loss program.</p> <p>Subjects/methods</p> <p>100 obese men and women over 30 years of age with a body mass index (BMI) between 27 to 40 kg/m<sup>2 </sup>were randomized to one of two isocaloric weight loss meal plans 1). HP group: providing 2.2 g protein/kg of lean body mass (LBM)/day or 2). SP group: providing 1.1 g protein/kg LBM/day. Meal replacement (MR) was used twice daily (one meal, one snack) for 3 months and then once a day for 9 months. Body weight, lipid profiles, liver function, renal function and bone density were measured at baseline and 12 months.</p> <p>Results</p> <p>Seventy subjects completed the study. Both groups lost weight (HP -4.29 ± 5.90 kg vs. SP -4.66 ± 6.91 kg, p < 0.01) and there was no difference in weight loss observed between the groups at one year. There was no significant change noted in liver function [AST (HP -2.07 ± 10.32 U/L, p = 0.28; SP 0.27 ± 6.67 U/L, p = 0.820), ALT (HP -1.03 ± 10.08 U/L, p = 0.34; SP -2.6 ± 12.51 U/L, p = 0.24), bilirubin (HP 0.007 ± 0.33, U/L, p = 0.91; SP 0.07 ± 0.24 U/L, p = 0.120), alkaline phosphatase (HP 2.00 ± 9.07 U/L, p = 0.240; SP -2.12 ± 11.01 U/L, p = 0.280)], renal function [serum creatinine (HP 0.31 ± 1.89 mg/dL, p = 0.380; SP -0.05 ± 0.15 mg/dL, p = 0.060), urea nitrogen (HP 1.33 ± 4.68 mg/dL, p = 0.130; SP -0.24 ± 3.03 mg/dL, p = 0.650), 24 hour urine creatinine clearance (HP -0.02 ± 0.16 mL/min, p = 0.480; SP 1.18 ± 7.53 mL/min, p = 0.400), and calcium excretion (HP -0.41 ± 9.48 mg/24 hours, p = 0.830; SP -0.007 ± 6.76 mg/24 hours, p = 0.990)] or in bone mineral density by DEXA (HP 0.04 ± 0.19 g/cm<sup>2</sup>, p = 0.210; SP -0.03 ± 0.17 g/cm<sup>2</sup>, p = 0.320) in either group over one year.</p> <p>Conclusions</p> <p>These studies demonstrate that protein-enriched meals replacements as compared to standard meal replacements recommended for weight management do not have adverse effects on routine measures of liver function, renal function or bone density at one year. Clinicaltrial.gov: NCT01030354.</p

    Diagnosing dementia: No easy job

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>From both clinical experience and research we learned that in complex progressive disorders such as dementia, diagnosis includes multiple steps, each with their own clinical and research characteristics.</p> <p>Discussion</p> <p>Diagnosing starts with a trigger phase in which the GP gradually realizes that dementia may be emerging. This is followed by a disease-oriented diagnosis and subsequently a care -oriented diagnosis. In parallel the GP should consider the consequences of this process for the caregiver and the interaction between both. As soon as a comprehensive diagnosis and care plan are available, monitoring follows.</p> <p>Summary</p> <p>We propose to split the diagnostic process into four diagnostic steps, followed by a monitoring phase. We recommend to include these steps when designing studies on screening, diagnosis and monitoring of patients with dementia and their families.</p

    Silicic volcanism on Mars evidenced by tridymite in high-SiO2 sedimentary rock at Gale crater

    Get PDF
    Tridymite, a SiO2 mineral that crystallizes at low pressures and high temperatures (>870 °C) from high-SiO2 materials, was detected at high concentrations in a sedimentary mudstone in Gale crater, Mars. Mineralogy and abundance were determined by X-ray diffraction using the Chemistry and Mineralogy instrument on the Mars Science Laboratory rover Curiosity. Terrestrial tridymite is commonly associated with silicic volcanism where high temperatures and high-silica magmas prevail, so this occurrence is the first in situ mineralogical evidence for martian silicic volcanism. Multistep processes, including high-temperature alteration of silica-rich residues of acid sulfate leaching, are alternate formation pathways for martian tridymite but are less likely. The unexpected discovery of tridymite is further evidence of the complexity of igneous petrogenesis on Mars, with igneous evolution to high-SiO2 compositions
    corecore