    Differential contractile response of critically ill patients to neuromuscular electrical stimulation

    Get PDF
    BACKGROUND: Neuromuscular electrical stimulation (NMES) has been investigated as a preventative measure for intensive care unit-acquired weakness. Trial results remain contradictory and therefore inconclusive. As it has been shown that NMES does not necessarily lead to a contractile response, our aim was to characterise the response of critically ill patients to NMES and investigate potential outcome benefits of an adequate contractile response. METHODS: This is a sub-analysis of a randomised controlled trial investigating early muscle activating measures together with protocol-based physiotherapy in patients with a SOFA score ≥ 9 within the first 72 h after admission. Included patients received protocol-based physiotherapy twice daily for 20 min and NMES once daily for 20 min, bilaterally on eight muscle groups. Electrical current was increased up to 70 mA or until a contraction was detected visually or on palpation. Muscle strength was measured by a blinded assessor at the first adequate awakening and ICU discharge. RESULTS: One thousand eight hundred twenty-four neuromuscular electrical stimulations in 21 patients starting on day 3.0 (2.0/6.0) after ICU admission were included in this sub-analysis. Contractile response decreased from 64.4% on day 1 to 25.0% on day 7 with a significantly lower response rate in the lower extremities and proximal muscle groups. The electrical current required to elicit a contraction did not change over time (day 1, 50.2 [31.3/58.8] mA; day 7, 45.3 [38.0/57.5] mA). The electrical current necessary for a contractile response was higher in the lower extremities. At the first awakening, patients presented with significant weakness (3.2 [2.5/3.8] MRC score). When dividing the cohort into responders and non-responders (> 50% vs. ≤ 50% contractile response), we observed a significantly higher SOFA score in non-responders. The electrical current necessary for a muscle contraction in responders was significantly lower (38.0 [32.8/42.9] vs. 54.7 [51.3/56.0] mA, p < 0.001). Muscle strength showed higher values in the upper extremities of responders at ICU discharge (4.4 [4.1/4.6] vs. 3.3 [2.8/3.8] MRC score, p = 0.036). CONCLUSION: Patients show a differential contractile response to NMES, which appears to be dependent on the severity of illness and also relevant for potential outcome benefits. TRIAL REGISTRATION: ISRCTN ISRCTN19392591 , registered 17 February 201

    Dynamic thromboembolic left ventricular outflow tract obstruction after aggressive procoagulant treatment in hemorrhagic shock: a case report

    Get PDF
    Background: In cases of hypertrophic obstructive cardiomyopathy (HOCM), the systolic anterior motion of the mitral valve apparatus results in an obstruction of the left ventricular outflow tract (LVOT), which is known as the SAM [systolic anterior motion] phenomenon. Hypothetically, a pathological obstruction of the LVOT of a different etiology would result in a comparable hemodynamic instability, which would be refractory to inotrope therapy, and may be detectable through echocardiography. Case presentation: We observed a severely impaired left ventricular function due to a combination of a thrombotic LVOT obstruction and distinctive mitral regurgitation in a 56-year-old Caucasian, female patient after massive transfusion with aggressive procoagulant therapy. Initially, the patient had to be resuscitated due to cardiac arrest after a long-distance flight. The resuscitation attempts in combination with lysis therapy due to suspected pulmonary artery embolism were initially successful but resulted in traumatic liver injury, hemorrhagic shock and subsequent acute respiratory distress syndrome (ARDS). Oxygenation was stabilized with veno-venous extracorporeal membrane oxygenation (ECMO), but the hemodynamic situation deteriorated further. Transesophageal echocardiography (TEE) showed a massive, dynamic LVOT obstruction. Two thrombi were attached to the anterior leaflet of the mitral valve, resulting in a predominantly systolic obstruction. Unfortunately, the patient died of multiple-organ failure despite another round of lysis therapy and escalation of the ECMO circuit to a veno-venoarterial cannulation for hemodynamic support. Conclusion: Massive transfusion with aggressive procoagulant therapy resulted in mitral valve leaflet thrombosis with dynamic, predominantly systolic LVOT obstruction, comparable to the SAM phenomenon. The pathology was only detectable with a TEE investigation

    Clinical Guideline for Treating Acute Respiratory Insufficiency with Invasive Ventilation and Extracorporeal Membrane Oxygenation: Evidence-Based Recommendations for Choosing Modes and Setting Parameters of Mechanical Ventilation

    Get PDF
    For patients with acute respiratory insufficiency, mechanical (invasive) ventilation is a fundamental therapeutic measure to ensure sufficient gas exchange. Despite decades of strong research efforts, central questions on mechanical ventilation therapy are still answered incompletely. Therefore, many different ventilation modes and settings have been used in daily clinical practice without scientifically sound bases. At the same time, implementation of the few evidence-based therapeutic concepts (e.g., lung protective ventilation) into clinical practice is still insufficient. The aim of our guideline project Mechanical ventilation and extracorporeal gas exchange in acute respiratory insufficiency was to develop an evidence-based decision aid for treating patients with and on mechanical ventilation. It covers the whole pathway of invasively ventilated patients (including indications of mechanical ventilation, ventilator settings, additional and rescue therapies, and liberation from mechanical ventilation). To assess the quality of scientific evidence and subsequently derive recommendations, we applied the Grading of Recommendations, Assessment, Development and Evaluation method. For the first time, using this globally accepted methodological standard, our guideline contains recommendations on mechanical ventilation therapy not only for acute respiratory distress syndrome patients but also for all types of acute respiratory insufficiency. This review presents the two main chapters of the guideline on choosing the mode of mechanical ventilation and setting its parameters. The guideline group aimed that - by thorough implementation of the recommendations - critical care teams may further improve the quality of care for patients suffering from acute respiratory insufficiency. By identifying relevant gaps of scientific evidence, the guideline group intended to support the development of important research projects

    Clinical Guideline for Treating Acute Respiratory Insufficiency with Invasive Ventilation and Extracorporeal Membrane Oxygenation: Evidence-Based Recommendations for Choosing Modes and Setting Parameters of Mechanical Ventilation

    Get PDF
    For patients with acute respiratory insufficiency, mechanical (“invasive”) ventilation is a fundamental therapeutic measure to ensure sufficient gas exchange. Despite decades of strong research efforts, central questions on mechanical ventilation therapy are still answered incompletely. Therefore, many different ventilation modes and settings have been used in daily clinical practice without scientifically sound bases. At the same time, implementation of the few evidence-based therapeutic concepts (e.g., “lung protective ventilation”) into clinical practice is still insufficient. The aim of our guideline project “Mechanical ventilation and extracorporeal gas exchange in acute respiratory insufficiency” was to develop an evidence-based decision aid for treating patients with and on mechanical ventilation. It covers the whole pathway of invasively ventilated patients (including indications of mechanical ventilation, ventilator settings, additional and rescue therapies, and liberation from mechanical ventilation). To assess the quality of scientific evidence and subsequently derive recommendations, we applied the Grading of Recommendations, Assessment, Development and Evaluation method. For the first time, using this globally accepted methodological standard, our guideline contains recommendations on mechanical ventilation therapy not only for acute respiratory distress syndrome patients but also for all types of acute respiratory insufficiency. This review presents the two main chapters of the guideline on choosing the mode of mechanical ventilation and setting its parameters. The guideline group aimed that – by thorough implementation of the recommendations – critical care teams may further improve the quality of care for patients suffering from acute respiratory insufficiency. By identifying relevant gaps of scientific evidence, the guideline group intended to support the development of important research projects

    Clinical management and outcome of adult patients with extracorporeal life support device–associated intracerebral hemorrhage—a neurocritical perspective and grading

    Get PDF
    Intracerebral hemorrhage (ICH) is a devastating complication in patients treated with extracorporeal membrane oxygenation (ECMO) due to respiratory or cardiac issues. Neurosurgical evaluation and management of such cases has only insufficiently been studied. We conducted a retrospective, cohort study of adult patients treated with ECMO between January 2007 and January 2017 in a tertiary healthcare center. Demographics, clinical data, coagulation status, ICH characteristics, and treatment modalities were analyzed. The primary outcome parameter was defined as mortality caused by ICH during ECMO. 525 patients with ECMO therapy were eligible for analysis. An overall incidence for any type of intracranial bleeding of 12.3% was found. Small hemorrhages accounted for 6.4% and acute subdural and epidural hematoma for 1.2%. Twenty-four (4.6%) patients developed ICH, and 11 patients (46%) died due to the ICH. Mortality was significantly higher in patients with larger ICH volumes (86.8 +/- 34.8 ml vs 9.9 +/- 20.3 ml, p < 0.001), intraventricular hemorrhage (83% vs 8%, p = 0.01), and a fluid level inside the ICH (75% vs 31%, p = 0.04). All patients were classified according to the bleeding pattern on the initial CT scan into 3 types. Patients with type 1 bleeding were statistically more likely to die (p < 0.001). In 15 out of 24 patients (63%), correction of the coagulation status was possible within 12 h after ICH onset. Seven out of 9 patients (78%) without early coagulation correction died compared to 2 out of 15 patients (13%), in whom early coagulation correction was successful (p = 0.01). This is the first study evaluating the course and management of patients experiencing an ICH under ECMO therapy and establishing an ICH classification based on the bleeding patterns. Early correction of the coagulation is of paramount importance in the treatment of these patients

    Clinical Requirements of Future Patient Monitoring in the Intensive Care Unit: Qualitative Study

    Get PDF
    BACKGROUND: In the intensive care unit (ICU), continuous patient monitoring is essential to detect critical changes in patients' health statuses and to guide therapy. The implementation of digital health technologies for patient monitoring may further improve patient safety. However, most monitoring devices today are still based on technologies from the 1970s. OBJECTIVE: The aim of this study was to evaluate statements by ICU staff on the current patient monitoring systems and their expectations for future technological developments in order to investigate clinical requirements and barriers to the implementation of future patient monitoring. METHODS: This prospective study was conducted at three intensive care units of a German university hospital. Guideline-based interviews with ICU staff-5 physicians, 6 nurses, and 4 respiratory therapists-were recorded, transcribed, and analyzed using the grounded theory approach. RESULTS: Evaluating the current monitoring system, ICU staff put high emphasis on usability factors such as intuitiveness and visualization. Trend analysis was rarely used; inadequate alarm management as well as the entanglement of monitoring cables were rated as potential patient safety issues. For a future system, the importance of high usability was again emphasized; wireless, noninvasive, and interoperable monitoring sensors were desired; mobile phones for remote patient monitoring and alarm management optimization were needed; and clinical decision support systems based on artificial intelligence were considered useful. Among perceived barriers to implementation of novel technology were lack of trust, fear of losing clinical skills, fear of increasing workload, and lack of awareness of available digital technologies. CONCLUSIONS: This qualitative study on patient monitoring involves core statements from ICU staff. To promote a rapid and sustainable implementation of digital health solutions in the ICU, all health care stakeholders must focus more on user-derived findings. Results on alarm management or mobile devices may be used to prepare ICU staff to use novel technology, to reduce alarm fatigue, to improve medical device usability, and to advance interoperability standards in intensive care medicine. For digital transformation in health care, increasing the trust and awareness of ICU staff in digital health technology may be an essential prerequisite

    Efficacy and safety of argatroban in patients with acute respiratory distress syndrome and extracorporeal lung support

    Get PDF
    Background Extracorporeal membrane oxygenation (ECMO) or pumpless extracorporeal lung assist (pECLA) requires effective anticoagulation. Knowledge on the use of argatroban in patients with acute respiratory distress syndrome (ARDS) undergoing ECMO or pECLA is limited. Therefore, this study assessed the feasibility, efficacy and safety of argatroban in critically ill ARDS patients undergoing extracorporeal lung support. Methods This retrospective analysis included ARDS patients on extracorporeal lung support who received argatroban between 2007 and 2014 in a single ARDS referral center. As controls, patients who received heparin were matched for age, sex, body mass index and severity of illness scores. Major and minor bleeding complications, thromboembolic events, administered number of erythrocyte concentrates, thrombocytes and fresh-frozen plasmas were assessed. The number of extracorporeal circuit systems and extracorporeal lung support cannulas needed due to clotting was recorded. Also assessed was the efficacy to reach the targeted activated partial thromboplastin time (aPTT) in the first consecutive 14 days of therapy, and the controllability of aPTT values is within a therapeutic range of 50–75 s. Fisher’s exact test, Mann–Whitney U tests, Friedman tests and multivariate nonparametric analyses for longitudinal data (MANOVA; Brunner’s analysis) were applied where appropriate. Results Of the 535 patients who met the inclusion criteria, 39 receiving argatroban and 39 matched patients receiving heparin (controls) were included. Baseline characteristics were similar between the two groups, including severity of illness and organ failure scores. There were no significant differences in major and minor bleeding complications. Rates of thromboembolic events were generally low and were similar between the two groups, as were the rates of transfusions required and device-associated complications. The controllability of both argatroban and heparin improved over time, with a significantly increasing probability to reach the targeted aPTT corridor over the first days (p < 0.001). Over time, there were significantly fewer aPTT values below the targeted aPTT goal in the argatroban group than in the heparin group (p < 0.05). Both argatroban and heparin reached therapeutic aPTT values for adequate application of extracorporeal lung support. Conclusions Argatroban appears to be a feasible, effective and safe anticoagulant for critically ill ARDS patients undergoing extracorporeal lung support

    Creation of an Evidence-Based Implementation Framework for Digital Health Technology in the Intensive Care Unit: Qualitative Study

    Get PDF
    Background: Digital health technologies such as continuous remote monitoring and artificial intelligence–driven clinical decision support systems could improve clinical outcomes in intensive care medicine. However, comprehensive evidence and guidelines for the successful implementation of digital health technologies into specific clinical settings such as the intensive care unit (ICU) are scarce. We evaluated the implementation of a remote patient monitoring platform and derived a framework proposal for the implementation of digital health technology in an ICU. Objective: This study aims to investigate barriers and facilitators to the implementation of a remote patient monitoring technology and to develop a proposal for an implementation framework for digital health technology in the ICU. Methods: This study was conducted from May 2018 to March 2020 during the implementation of a tablet computer–based remote patient monitoring system. The system was installed in the ICU of a large German university hospital as a supplementary monitoring device. Following a hybrid qualitative approach with inductive and deductive elements, we used the Consolidated Framework for Implementation Research and the Expert Recommendations for Implementing Change to analyze the transcripts of 7 semistructured interviews with clinical ICU stakeholders and descriptive questionnaire data. The results of the qualitative analysis, together with the findings from informal meetings, field observations, and previous explorations, provided the basis for the derivation of the proposed framework. Results: This study revealed an insufficient implementation process due to lack of staff engagement and few perceived benefits from the novel solution. Further implementation barriers were the high staff presence and monitoring coverage in the ICU. The implementation framework includes strategies to be applied before and during implementation, targeting the implementation setting by involving all ICU stakeholders, assessing the intervention’s adaptability, facilitating the implementation process, and maintaining a vital feedback culture. Setting up a unit responsible for implementation, considering the guidance of an implementation advisor, and building on existing institutional capacities could improve the institutional context of implementation projects in the ICU. Conclusions: Implementation of digital health in the ICU should involve a thorough preimplementation assessment of the ICU’s need for innovation and its readiness to change, as well as an ongoing evaluation of the implementation conditions. Involvement of all stakeholders, transparent communication, and continuous feedback in an equal atmosphere are essential, but leadership roles must be clearly defined and competently filled. Our proposed framework may guide health care providers with concrete, evidence-based, and step-by-step recommendations for implementation practice, facilitating the introduction of digital health in intensive care. Trial Registration: ClinicalTrials.gov NCT03514173; https://clinicaltrials.gov/ct2/show/NCT0351417

    a prospective clinical trial

    Get PDF
    Background Continuous glucose monitoring (CGM) has not yet been implemented in the intensive care unit (ICU) setting. The purpose of this study was to evaluate reliability, feasibility, nurse acceptance and accuracy of the Medtronic Sentrino® CGM system in critically ill patients. Methods Sensors were inserted into the subcutaneous tissue of the patient’s thigh, quantifying interstitial glucose concentration for up to 72 h per sensor. Reliability and feasibility analysis included frequency of data display, data gaps and reasons for sensor removal. We surveyed nurse acceptance in a questionnaire. For the accuracy analysis, we compared sensor values to glucose values obtained via blood gas analysis. Potential benefits of CGM were investigated in intra- individual analyses of factors, such as glycemic variability or time in target range achieved with CGM compared to that achieved with intermittent glucose monitoring. Results The device generated 68,655 real-time values from 31 sensors in 20 critically ill patients. 532 comparative blood glucose values were collected. Data were displayed during 32.5 h [16.0/62.4] per sensor, which is 45.1 % of the expected time of 72 h and 84.8 % of 37.9 h actual monitoring time. 21 out of 31 sensors were removed prematurely. 79.1 % of the nursing staff rated the device as not beneficial; the response rate was one- third. Mean absolute relative difference was 15.3 % (CI 13.5–17.0 %). Clarke error grid: 76.9 % zone A, 21.6 % zone B, 0.2 % zone C, 0.9 % zone D, 0.4 % zone E. Bland–Altman plot: mean bias +0.53 mg/dl, limits of agreement +64.6 and −63.5 mg/dl. Accuracy deteriorated during elevated glycemic variability and in the hyperglycemic range. There was no reduction in dysglycemic events during CGM compared to 72 h before and after CGM. If CGM was measuring accurately, it identified more hyperglycemic events when compared to intermittent measurements. This study was not designed to evaluate potential benefits of CGM on glucose control. Conclusions The subcutaneous CGM system did not perform with satisfactory accuracy, feasibility, or nursing acceptance when evaluated in 20 medical-surgical ICU patients. Low point accuracy and prolonged data gaps significantly limited the potential clinical usefulness of the CGM trend data. Accurate continuous data display, with a MARD < 14 %, showed potential benefits in a subgroup of our patients. Trial registration NCT02296372; Ethic vote Charité EA2/095/1