1,441 research outputs found
Sub-wavelength diffraction-free imaging with low-loss metal-dielectric multilayers
We demonstrate numerically the diffraction-free propagation of sub-wavelength
sized optical beams through simple elements built of metal-dielectric
multilayers. The proposed metamaterial consists of silver and a high refractive
index dielectric, and is designed using the effective medium theory as strongly
anisotropic and impedance matched to air. Further it is characterised with the
transfer matrix method, and investigated with FDTD. The diffraction-free
behaviour is verified by the analysis of FWHM of PSF in the function of the
number of periods. Small reflections, small attenuation, and reduced Fabry
Perot resonances make it a flexible diffraction-free material for arbitrarily
shaped optical planar elements with sizes of the order of one wavelength.Comment: 5 pages, 4 figure
Combined QCD and electroweak analysis of HERA data
A simultaneous fit of parton distribution functions (PDFs) and electroweak
parameters to HERA data on deep inelastic scattering is presented. The input
data are the neutral current and charged current inclusive cross sections which
were previously used in the QCD analysis leading to the HERAPDF2.0 PDFs. In
addition, the polarisation of the electron beam was taken into account for the
ZEUS data recorded between 2004 and 2007. Results on the vector and
axial-vector couplings of the Z boson to u- and d-type quarks, on the value of
the electroweak mixing angle and the mass of the W boson are presented. The
values obtained for the electroweak parameters are in agreement with Standard
Model predictions.Comment: 32 pages, 10 figures, accepted by Phys. Rev. D. Small corrections
from proofing process and small change to Fig. 12 and Table
Search for a narrow baryonic state decaying to and in deep inelastic scattering at HERA
A search for a narrow baryonic state in the and
system has been performed in collisions at HERA with the ZEUS detector
using an integrated luminosity of 358 pb taken in 2003-2007. The search
was performed with deep inelastic scattering events at an centre-of-mass
energy of 318 GeV for exchanged photon virtuality, , between 20 and 100
. Contrary to evidence presented for such a state around 1.52
GeV in a previous ZEUS analysis using a sample of 121 pb taken in
1996-2000, no resonance peak was found in the invariant-mass
distribution in the range 1.45-1.7 GeV. Upper limits on the production cross
section are set.Comment: 16 pages, 4 figures, accepted by Phys. Lett. B. Minor changes from
journal reviewing process, including a small correction to figure
Limits on the effective quark radius from inclusive scattering at HERA
The high-precision HERA data allows searches up to TeV scales for Beyond the
Standard Model contributions to electron-quark scattering. Combined
measurements of the inclusive deep inelastic cross sections in neutral and
charged current scattering corresponding to a luminosity of around 1
fb have been used in this analysis. A new approach to the beyond the
Standard Model analysis of the inclusive data is presented; simultaneous
fits of parton distribution functions together with contributions of "new
physics" processes were performed. Results are presented considering a finite
radius of quarks within the quark form-factor model. The resulting 95% C.L.
upper limit on the effective quark radius is cm.Comment: 10 pages, 4 figures, accepted by Phys. Lett.
Measurement of the cross-section ratio sigma_{psi(2S)}/sigma_{J/psi(1S)} in deep inelastic exclusive ep scattering at HERA
The exclusive deep inelastic electroproduction of and
at an centre-of-mass energy of 317 GeV has been studied with the ZEUS
detector at HERA in the kinematic range GeV,
GeV and GeV, where is the photon virtuality, is the
photon-proton centre-of-mass energy and is the squared four-momentum
transfer at the proton vertex. The data for GeV were taken in
the HERA I running period and correspond to an integrated luminosity of 114
pb. The data for GeV are from both HERA I and HERA II
periods and correspond to an integrated luminosity of 468 pb. The decay
modes analysed were and for the
and for the . The cross-section ratio
has been measured as a function of
and . The results are compared to predictions of QCD-inspired
models of exclusive vector-meson production.Comment: 24 pages, 8 figure
Measurement of neutral current e+/-p cross sections at high Bjorken x with the ZEUS detector
The neutral current e+/-p cross section has been measured up to values of
Bjorken x of approximately 1 with the ZEUS detector at HERA using an integrated
luminosity of 187 inv. pb of e-p and 142 inv. pb of e+p collisions at sqrt(s) =
318GeV. Differential cross sections in x and Q2, the exchanged boson
virtuality, are presented for Q2 geq 725GeV2. An improved reconstruction method
and greatly increased amount of data allows a finer binning in the high-x
region of the neutral current cross section and leads to a measurement with
much improved precision compared to a similar earlier analysis. The
measurements are compared to Standard Model expectations based on a variety of
recent parton distribution functions.Comment: 39 pages, 9 figure
Measurement of the top quark mass using the matrix element technique in dilepton final states
We present a measurement of the top quark mass in pp¯ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider. The data were collected by the D0 experiment corresponding to an integrated luminosity of 9.7 fb−1. The matrix element technique is applied to tt¯ events in the final state containing leptons (electrons or muons) with high transverse momenta and at least two jets. The calibration of the jet energy scale determined in the lepton+jets final state of tt¯ decays is applied to jet energies. This correction provides a substantial reduction in systematic uncertainties. We obtain a top quark mass of mt=173.93±1.84 GeV
Multicenter evaluation of the vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of gram-positive aerobic bacteria
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 system (bioMérieux, Inc.) for the identification of aerobic Gram-positive bacteria. A total of 1,146 unique isolates, representing 13 genera and 42 species, were analyzed, and results were compared to those obtained by nucleic acid sequence-based identification as the reference method. For 1,063 of 1,146 isolates (92.8%), the Vitek MS provided a single identification that was accurate to the species level. For an additional 31 isolates (2.7%), multiple possible identifications were provided, all correct at the genus level. Mixed-genus or single-choice incorrect identifications were provided for 18 isolates (1.6%). Although no identification was obtained for 33 isolates (2.9%), there was no specific bacterial species for which the Vitek MS consistently failed to provide identification. In a subset of 463 isolates representing commonly encountered important pathogens, 95% were accurately identified to the species level and there were no misidentifications. Also, in all but one instance, the Vitek MS correctly differentiated Streptococcus pneumoniae from other viridans group streptococci. The findings demonstrate that the Vitek MS system is highly accurate for the identification of Gram-positive aerobic bacteria in the clinical laboratory setting
Building’ healt leakage investigation aimed at development of energy saving guidelines
This article is talking about developed technique of heat losses calculation for various purposes buildings. On the basis of performed calculations there were conducted detailed researches of the heat losses through buildingsfencing structures (wall, windows, floors, ceilings, etc.) for particular building, the installed capacity of its appliances was 208 kW. Executed researches enable ustomake a conclusion that the heat losses were 145,1 kW.Thus, 62,9 kW of capacity is excessive and therefore the equivalent number of heating units are to be excluded.Разработана методика расчёта потерь теплоты в зданиях различного назначения. На основе выполненных расчётов приведены детальные исследования потерь теплоты через ограждающие конструкции (стены, окна, полы, потолки, и проч.) конкретного здания, установленная мощность отопительных приборов которого 208 кВт. Выполненные исследования позволили заключить, что потери теплоты составляют 145,1 кВт. Таким образом, 62,9 кВт установленной мощности являются избыточными и, следовательно, эквивалентное число отопительных приборов необходимоисключить
- …