8 research outputs found

    Assessment of different types of intra oral scanners and 3D printers on the accuracy of printed models : an in vitro study

    Get PDF
    3D printing technology is a reality in Dentistry and presents several ways to obtain a printed model. The aim of this study was to verify the influence of different types of intraoral scanners and 3D printers on the accuracy of printed models in comparis

    Effects of sandblasting of prosthetic abutment surfaces on the tensile strength of cement-retained crowns, using a cementing technique: an in vitro study

    Get PDF
    Objective: The tensile strength effects on the sandblasting of the abutment associated with a cementing technique are not well documented. The objective of this study is to analyze the tensile strength of prosthetic crowns cemented on standard and sandblasted abutments, using a cementing technique. Methods: Experimental groups were formed according to ce­menting technique (control and practice abutment technique) and prosthetic abutment roughness (standard and sandblas­ted), totaling forty specimens. The crowns were cemented with Zinc Phosphate cement. Statistical analysis was conducted with an α at 0.05. Results: Considering the cementation techniques analysis, there were no statistically significant differen­ces between the groups, with mean tensile strength values of 157.83±22.16 N for the control technique, and 159.95±46.40 N for the practice abutment technique on the standard surface. Result analysis of the control technique (626.23±34.80 N) and practice abutment technique (642.62±94.00 N) indicated no significant differences on the sandblasted surface. Consi­dering the surface roughness analysis, significant differences were observed, with values of 157.83±22.16 N for the control technique/standard surface group and 626.23±34.80 N for the control technique/sandblasted surface group. Significant differences were observed in the practice abutment technique/standard surface group with 159.95±46.40 N values, compa­red to the 642.62±94.00 N value for the practice abutment technique/sandblasted group. Conclusions: The practice abut­ment cementing technique showed no significant differences with the control technique, regarding to the tensile strength, in the two surfaces (standard and sandblasted) used in the study. The sandblasting of prosthetic abutments led to a signifi­cant increase on the tensile strength considering the two studied cementation techniques.Objetivos: Os efeitos de resistência à tração no jateamento do pilar associado a uma técnica de cimentação não estão bem documentados. O objetivo deste estudo é analisar a resistência à tração de coroas protéticas cimentadas em munhões padrões e asperizados, utilizando uma técnica de cimentação. Métodos: Os grupos experimentais foram formados de acordo com a técnica de cimentação (técnica de controle e prática de pilares) e a rugosidade do pilar protético (padrão e asperizado), totalizando quarenta espécimes. As coroas foram cimentadas com cimento de fosfato de zinco. A análise estatística foi conduzida a um valor de α=0,05. Resultados: Na análise das técnicas de cimentação não houve diferenças estatisticamente significativas entre os grupos, com valores médios de resistência à tração de 157,83±22,16 N para a técnica controle e 159,95±46,40 N para a técnica practice abutment na superfície padrão. A análise dos resultados na técnica controle (626,23±34,80 N) e na técnica practice abutment (642,62±94,00 N), na superfície jateada, também não indicaram diferenças significativas. Na análise da rugosidade da superfície, observaram-se diferenças significativas, com valores de 157,83±22,16 N para o grupo técnica controle/superfície padrão e 626,23±34,80 N para o grupo técnica controle/superfície asperizada. Foram observadas diferenças significativas no grupo técnica Practice abutment/ superfície padrão com valores de 159,95±46,40 N comparado com o grupo técnica Practice abutment/grupo jateado, com valores de 642,62±94,00 N. Conclusões: A técnica de cimentação Practice abutment não mostrou diferenças significativas com a técnica controle, em relação à resistência à tração, nas duas superfícies (padrão e asperizada) usadas no estudo. O jateamento dos munhões protéticos levou a um aumento significativo da resistência à tração nas duas técnicas de cimentação estudadas

    A Contribution for the Study of the Propagation of Light through the Human Enamel and Dentine

    No full text
    Este trabalho estuda a propagação da luz no esmalte e dentina humanos, através da transmitância direta e absorbância no intervalo de comprimento de onda de 200 a 3200nm, e através da transmitância total no intervalo de onda de 380 a 760nm. Foram utilizadas secções de 30 molares humanos íntegros, que foram seccionados nos sentidos VL (vestíbulo Lingual), MD (mésio distal) e OC (ocluso cervical). As espessuras utilizadas foram de 0,5mm e 0,25mm. Foram agrupados 5 dentes para cada sentido para cada espessura. Esmalte e dentina estavam presentes de maneira simultânea na mesma amostra. A absorbância foi calculada, a partir dos espectros de transmitância direta, aplicando-se a Lei e Beer-Lambert. Os espectros de transmitância total foram obtidos no espectro visível, e comparados, em média, com os espectros de transmitância direta no mesmo intervalo, para obter a energia difusa das amostras. Os espectros UV (Ultravioleta), VIS (Visível) e IV (Infravermelho), foram tratados separadamente para cada tecido e espessura. No infravermelho foram identificados os picos de transmitância e absorbância para ambos os tecidos. Os valores de transmitância e absorbância para cada faixa espectral foram tratados pela ANOVA, e os grupos comparados pelo teste de intervalo de confiança (95%). Os resultados mostraram que, as propriedades ópticas do esmalte e dentina diferem no que diz respeito as 3 faixas espectrais testadas. Os resultados também mostram que as propriedades ópticas são dependentes da espessura e do sentido de seccionamento dos dentes. A pesar das diferenças apresentadas entre os espectros, as curvas espectrais mostraram um padrão semelhante para todas as amostras de dentina e de esmalte, independente da espessura. Este comportamento possibilitou a identificação de picos comuns nos espectros estudados.This research studies the propagation of light in the human enamel and dentine, through direct transmittance and absorbance in the 200 to 3200nm wavelength interval, and through total transmittance in the 380 to 760nm wavelength interval. The study employed sections of 30 human integral molars, which were sectioned in the VL directions (vestibule Lingual), MD (mesio distal), and OC (occlusion cervical). The thicknesses used were from 0.5mm to 0.25mm. Five teeth were grouped in each direction for each thickness. Enamel and dentine were simultaneously present in the same sample. Absorbance was calculated from the direct transmittance specters, applying the Beer-Lambert Law. Total transmittance specters were obtained in the visible specter, and compared, on average, with the Total transmittance specters in the same interval, to obtain the diffuse energy of the samples. UV (Ultraviolet), VIS (Visible), and IV (Infrared) specters, were treated separately for each tissue and thickness. In infrared, the transmittance and absorbance peaks were identified for both tissues. The transmittance and absorbance spectral range were treated by ANOVA, and the groups compared by the confidence interval test (95%). The results showed that the optical properties of the enamel and dentine differ with regard to the three tested spectral ranges. The results also showed that the optical properties are dependent on the thickness and the direction of the sectioning of the teeth. Despite the differences found between the specters, the special curves showed a similar pattern for all samples of dentine and enamel, independently of the thickness. This behavior allowed the identification of common peaks in the specters under study

    A contribution to the study of the influence of thickness, shade, opacity and commercial brands of feldspatic porcelains on the propagation of visible light, through the Kubelka Munk Theory and its implications in dentistry, for the wavelength intervals of 410500nm and 410 700nm

    No full text
    O estudo da propagação da luz nas porcelanas é importante para entender seu comportamento óptico frente a situações clínicas como fotoativação de cimentos resinosos e sua resposta estética, quando observada sobre diferentes fundos. Este trabalho estudou a influência da espessura, cor, opacidade e marca comercial das porcelanas feldspáticas na propagação da luz visível, através da teoria de KubelkaMunk (KM), nos intervalos de comprimento de onda de 410500nm e de 410700nm. Foram confeccionados discos de 12,5mm por 1 mm de espessura de porcelana feldspática de duas opacidades, corpo (B) e corpo opaco (BO), das marcas Vintage Halo (HALO), Noritake Super Porcelain EX3 (NORI) e IPS dSIGN (IPS), nas cores A1, A35 e B3 (n=7). Os discos foram polidos através de uma série de lixas abrasivas até a granulação 600 e acondicionados individualmente em ambiente seco. Os discos tiveram suas curvas espectrais de refletância obtidos em contato óptico, sobre fundo branco e preto, através do uso de um espectrofotômetro com esfera de integração acoplada, no intervalo de comprimento de onda de 410700nm. As curvas de refletância foram inseridas na teoria KM, para obtenção e análise quantitativa e qualitativa das propriedades ópticas de cada material. As análises qualitativas envolveram a observação do comportamento espectral das curvas de espalhamento, absorção, espessura infinita e reflexão para todos aos materiais em função do comprimento de onda. As análises quantitativas envolveram a obtenção das espessuras ópticas estimadas em extinções crescentes de 50% (X50), 90% (X90), 95% (X95) e infinita 99.9% (X99.9), para o intervalo de comprimento de onda de 410500nm e a obtenção da espessura óptica infinita 99.9% (X) e dos Parâmetros de Translucidez (TP), estimados nas espessuras de 0.5mm (TP0.5), 1.25mm (TP1.25) e 2.00mm (TP2.00), para o intervalo de comprimento de onda de 410700nm. Os Parâmetros de Translucidez foram utilizados para avaliar o efeito de mascaramento da porcelana sobre os fundos utilizados. Os resultados mostraram que todos os fatores (cor, opacidade e marca comercial) exerceram influência para atenuar a propagação da luz através dos espécimes. De maneira geral, a maior atenuação de luz esteve ligada à porcelanas de corpo opaco e mais saturadas (cor A35 e B3). Em relação à marca comercial a porcelana IPS, atenuou de maneira geral mais luz nas cores A35 e B3 em relação às mesmas cores das marcas HALO e NORI nas espessuras ópticas estudadas. Os valores de espessura óptica infinita (espessura onde a energia transmitida é praticamente zero), para ambos os intervalos de comprimento de onda, para todos os materiais, superaram os limites de espessura clínica indicados pela literatura. Isto implicou que, no caso do intervalo de 410 a 500nm, a energia transmitida pode girar de 20 a 5% para as porcelanas de corpo, e de 10 a 5%, para as de corpo opaco e, no caso do mascaramento, as porcelanas serão mais influenciadas por fundos que apresentarem resposta colorimétrica acentuada nas regiões alaranjadas e avermelhadas do espectro visível. As análises qualitativas mostraram que para todos os materiais e espessuras a luz será preferencialmente atenuada no início do espectro, intervalo de 410 a 500nm e menos atenuada em direção ao final do espectro visível. Os resultados também mostraram que com o aumento da espessura, a atenuação aumentou, e que a relação entre espessura e atenuação é não linear.The study of light propagation through porcelains is important to understand its optical behavior in front of clinical situations such as the photoactivation of luting cements and their esthetic responses, when observed against different backgrounds. This research studies the influence of thickness, shade, opacity, and commercial brands of feldspatic porcelains on the propagation of visible light through the Kubelka Munk Theory for the wavelength intervals of 410500nm and 410700nm. Discs with 12,5mm in diameter and thickness of 1mm were prepared with feldspatic porcelain in two opacities, body (B) and opaque body (BO), three commercial brands; Vintage Halo (HALO), Noritake Super Porcelain EX3 (NORI), and IPS dSIGN (IPS), and three shades, A1, A35, and B3 (n=7). The discs were polished with a series of waterproof sandpapers down to a #600 grade sandpaper, and individually stored in a dry environment. The spectral reflectance curves were acquired from the disks on optical contact, against white and black backgrounds, with a spectrometer with a diffuse reflectance attachment (an attached integration sphere), in the wavelength interval of 410700nm. The reflectance spectra were inserted in the KM theory to quantitatively and qualitatively obtain and analyze the optical properties of each material. The qualitative analyses were obtained from the observation of the spectral behavior of scattering, absorption, infinite optical thickness, and reflection spectra for all materials as a function of the wavelength. The quantitative analyses involved obtaining the predicted optical thicknesses in extinctions with increments of 50% (X50), 90% (X90), 95% (X95) and infinite 99.9% (X99.9), for the wavelength interval of 410500nm and the obtaining of the infinite optical thickness 99.9% (X) and the translucency parameter (TP) estimated as 0.5mm (TP0.5), 1.25mm (TP1.25) e 2.00mm (TP2.00) thicknesses, for the wavelength interval of 410700nm. The Translucency parameters were used to evaluate the porcelain masking effect against the tested backgrounds. The results showed that all factors (Shade, Opacity, and Commercial Brand) exerted influence to attenuate the light propagation through the specimens. In general, a higher light attenuation was linked to porcelains exhibiting more saturated shades (A35, and B3) and body opaque types. The commercial brand IPS porcelain shades A35 and B3, generally attenuated more light than the same shades of HALO and NORI for the studied optical thicknesses. The infinite optical thicknesses values (thicknesses where the transmitted light is close to zero) is above the clinical thickness reported in the literature for all materials and both wavelength intervals. This fact implied that regarding the 410500nm interval, the body porcelain could transmit from 20 to 5% of the energy, while the opaque body transmits from 10 to 5%. The masking effect of the porcelains will be increasingly translucid against the background with increased colorimetric response on the Red Orange regions of the visible spectra. The qualitative analysis showed that for all materials and thicknesses, the light will preferably be attenuated in the beginning of the spectra, on the 410500nm interval e and will be less attenuated towards the ending of the visible spectra. The results also showed that the attenuation increased with the increase of the thickness, and the relationship between thickness and attenuation is nonlinear

    A Contribution for the Study of the Propagation of Light through the Human Enamel and Dentine

    Get PDF
    Este trabalho estuda a propagação da luz no esmalte e dentina humanos, através da transmitância direta e absorbância no intervalo de comprimento de onda de 200 a 3200nm, e através da transmitância total no intervalo de onda de 380 a 760nm. Foram utilizadas secções de 30 molares humanos íntegros, que foram seccionados nos sentidos VL (vestíbulo – Lingual), MD (mésio distal) e OC (ocluso cervical). As espessuras utilizadas foram de 0,5mm e 0,25mm. Foram agrupados 5 dentes para cada sentido para cada espessura. Esmalte e dentina estavam presentes de maneira simultânea na mesma amostra. A absorbância foi calculada, a partir dos espectros de transmitância direta, aplicando-se a Lei e Beer-Lambert. Os espectros de transmitância total foram obtidos no espectro visível, e comparados, em média, com os espectros de transmitância direta no mesmo intervalo, para obter a energia difusa das amostras. Os espectros UV (Ultravioleta), VIS (Visível) e IV (Infravermelho), foram tratados separadamente para cada tecido e espessura. No infravermelho foram identificados os picos de transmitância e absorbância para ambos os tecidos. Os valores de transmitância e absorbância para cada faixa espectral foram tratados pela ANOVA, e os grupos comparados pelo teste de intervalo de confiança (95%). Os resultados mostraram que, as propriedades ópticas do esmalte e dentina diferem no que diz respeito as 3 faixas espectrais testadas. Os resultados também mostram que as propriedades ópticas são dependentes da espessura e do sentido de seccionamento dos dentes. A pesar das diferenças apresentadas entre os espectros, as curvas espectrais mostraram um padrão semelhante para todas as amostras de dentina e de esmalte, independente da espessura. Este comportamento possibilitou a identificação de picos comuns nos espectros estudados.This research studies the propagation of light in the human enamel and dentine, through direct transmittance and absorbance in the 200 to 3200nm wavelength interval, and through total transmittance in the 380 to 760nm wavelength interval. The study employed sections of 30 human integral molars, which were sectioned in the VL directions (vestibule – Lingual), MD (mesio distal), and OC (occlusion cervical). The thicknesses used were from 0.5mm to 0.25mm. Five teeth were grouped in each direction for each thickness. Enamel and dentine were simultaneously present in the same sample. Absorbance was calculated from the direct transmittance specters, applying the Beer-Lambert Law. Total transmittance specters were obtained in the visible specter, and compared, on average, with the Total transmittance specters in the same interval, to obtain the diffuse energy of the samples. UV (Ultraviolet), VIS (Visible), and IV (Infrared) specters, were treated separately for each tissue and thickness. In infrared, the transmittance and absorbance peaks were identified for both tissues. The transmittance and absorbance spectral range were treated by ANOVA, and the groups compared by the confidence interval test (95%). The results showed that the optical properties of the enamel and dentine differ with regard to the three tested spectral ranges. The results also showed that the optical properties are dependent on the thickness and the direction of the sectioning of the teeth. Despite the differences found between the specters, the special curves showed a similar pattern for all samples of dentine and enamel, independently of the thickness. This behavior allowed the identification of common peaks in the specters under study

    Acurácia de Modelos Impressos obtidos a partir de Escaneamento Intra-oral

    Get PDF
    Objetivos: Comparar a acurácia de dois métodos de fabricação de modelos físicos: I) escaneamento intra-oral e modelos impressos em resina; e II) moldagem de silicone de adição e modelo de gesso. Materiais e métodos: Utilizou-se um manequim odontológico como modelo mestre, o qual foi comparado a cinco modelos de gesso (g1) e cinco modelos impressos em resina (g2) por meio de análises de medições lineares em quatro sítios de medição (M1, M2, M3 e M4) com um instrumento de medição por imagem. Os valores médios dos modelos experimentais foram comparados aos do modelo mestre utilizando-se o Teste-t. Para um mesmo local, as amostras de cada grupo foram comparadas por meio do Teste-t para amostras independente. Para todos os testes, foi adotado o nível de significância de 5% (0,05). Resultados: Os intervalos de confiança dos sítios M1, M2, e M4 para os modelos de gesso e resina apresentaram distância linear estatisticamente menor quando comparados aos valores do modelo de referência. Em M3, o valor médio dos modelos de gesso não foi estatisticamente diferente do valor médio da referência (p > 0,05); entretanto, os modelos impressos em resina apresentaram valor médio estatisticamente diferente (p < 0,05), bem como menores valores de distância linear. Conclusões: Quando comparados aos modelos de gesso, os modelos impressos em resina diferiram muito do modelo mestre, indicando a necessidade de padronização do protocolo de impressão, pois suas variáveis podem influenciar no nível de acurácia dos modelos impressos.Objectives: To compare the accuracy of two methods for the manufacturing of physical models: I) intraoral scanning and resin-printed models; and II) addition silicone impression and gypsum model. Materials and methods: A dental manikin was used as the master model and compared with five gypsum models (g1) and five resin printed models (g2) by analyzing linear measurements at four sites (M1, M2, M3, and M4) using an image measuring instrument. The mean values of the experimental models were compared to those of the master model using one-sample t-test. The samples of each group at the same site were compared with an independent t-test. For all tests, a significance level of 5% (0.05) was considered. Results: The confidence intervals from M1, M2, and M4 sites for both gypsum and resin models presented statistically lower linear distance when compared to the reference values. At m3, the mean value for the gypsum models was not statistically different from the reference mean value (p > 0.05); however, resin-printed models presented a statistically different mean value (p < 0.05), as well as lower values of linear distance. Conclusions: When compared to gypsum models, resin- printed models differed greatly from the master model, indicating the need for standardizing the printing protocol, for its variables may influence printed models accuracy

    Efficacy of low level laser therapy associated with exercises in knee osteoarthritis: a randomized double-blind study

    No full text
    Objectives: To estimate the effects of low level laser therapy in combination with a programme of exercises on pain, functionality, range of motion, muscular strength and quality of life in patients with osteoarthritis of the knee. Design: A randomized double-blind placebo-controlled trial with sequential allocation of patients to different treatment groups. Setting: Special Rehabilitation Services. Subjects: Forty participants with knee osteoarthritis, 2-4 osteoarthritis degree, aged between 50 and 75 years and both genders. Intervention: Participants were randomized into one of two groups: the laser group (low level laser therapy dose of 3 J and exercises) or placebo group (placebo laser and exercises). Main measures: Pain was assessed using a visual analogue scale (VAS), functionality using the Lequesne questionnaire, range of motion with a universal goniometer, muscular strength using a dynamometer, and activity using the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) questionnaire at three time points: (T1) baseline, (T2) after the end of laser therapy (three weeks) and (T3) the end of the exercises (11 weeks). Results: When comparing groups, significant differences in the activity were also found (P = 0.03). No other significant differences (P > 0.05) were observed in other variables. In intragroup analysis, participants in the laser group had significant improvement, relative to baseline, on pain (P = 0.001), range of motion (P = 0.01), functionality (P = 0.001) and activity (P < 0.001). No significant improvement was seen in the placebo group. Conclusion: Our findings suggest that low level laser therapy when associated with exercises is effective in yielding pain relief, function and activity on patients with osteoarthritis of the knees.Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) - Foundation of Research Support of Sao Paulo StateFundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) Foundation of Research Support of Sao Paulo StateCoordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES) - Coordination for the Improvement of Higher Level - or Education - PersonnelCoordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES) Coordination for the Improvement of Higher Level or Education Personne
    corecore