808 research outputs found

    Computer-assisted ex vivo, normothermic small bowel perfusion

    Get PDF
    Background: In the present study, a technique for computer-assisted, normothermic, oxygenated, ex vivo, recirculating small bowel perfusion was established as a tool to investigate organ pretreatment protocols and ischemia/reperfusion phenomena. A prerequisite for the desired setup was an organ chamber for ex vivo perfusion and the use of syngeneic whole blood as perfusate. Methods: The entire small bowel was harvested from Lewis rats and perfused in an organ chamber ex vivo for at least 2 h. The temperature was kept at 37 degrees C in a water bath. Three experimental groups were explored, characterized by different perfusion solutions. The basic perfusate consisted of syngeneic whole blood diluted with either NaCl, Krebs' solution or Krebs' solution and norepinephrine to a hematocrit of 30%. In addition, in each group l-glutamine was administered intraluminally. The desired perfusion pressure was 100 mm Hg which was kept constant with a computer-assisted data acquisition software, which measured an-line pressure, oxygenation, flow, temperature and pH and adjusted the pressure by changing the flow via a peristaltic pump. The viability of the preparation was tested by measuring oxygen consumption and maltose absorption, which requires intact enzymes of the mucosal brush border to break down maltose into glucose. Results: Organ perfusion in group 1 (dilution with NaCl) revealed problems such as hypersecretion into the bowel lumen, low vascular resistance and no maltose uptake. In contrast a viable organ could be demonstrated using Krebs' solution as dilution solution. The addition of norepinephrine led to an improved perfusion over the entire perfusion period. Maltose absorption was comparable to tests conducted with native small bower. Oxygen consumption was stable during the 2-hour perfusion period. Conclusions: The ex vivo perfusion system established enables small bowel perfusion for at least 2 h. The viability of the graft could be demonstrated. The perfusion time achieved is sufficient to study leukocyte/lymphocyte interaction with the endothelium of the graft vessels. In addition, a viable small bowel, after 2 h of ex vivo perfusion, facilitates testing of pretreatment protocols for the reduction of the immunogenicity of small bowel allografts. Copyright (C) 2000 S. Karger AG, Basel

    Microsurgical Technique of Simultaneous Pancreas/Kidney Transplantation in the Rat: Clinical Experience and Review of the Literature

    Get PDF
    Background: For experimental basic research, standardized transplantation models reflecting technical and immunologic aspects are necessary. This article describes an experimental model of combined pancreas/kidney transplantation (PKTx) in detail. Materials and Methods: Donor rats underwent en bloc pancreatectomy and nephrectomy. Revascularization was performed using the aorta with the superior mesenteric artery and the inferior vena cava with the portal vein. Exocrine drainage of the pancreas took place over a segment of the duodenum which was transplanted side-to-side to the jejunum. The kidney vessels were transplanted end-to-side. The ureter was anastomosed by patch technique. Postoperatively, serum parameters were monitored daily. Biopsies for histopathology were taken on days 5, 8 and 12. Results: All 12 recipients survived the combined PKTx without serious surgical complications. One thrombosis of the portal vein led to organ failure. Blood glucose levels were normal by the 3rd postoperative day. The transplanted duodenal segment showed slight villous atrophy, and the kidneys were well perfused without vascular complications. The anastomosis between ureter and bladder was leakproof. Conclusions: Excellent graft function and survival rates can be achieved due to simplified operation technique and short operation time. It may thus have high clinical relevance to immunologic issues within the scope of basic research. Copyright (C) 2009 S. Karger AG, Base

    X-ray Nanodiffraction on a Single SiGe Quantum Dot inside a Functioning Field-Effect Transistor

    Get PDF
    For advanced electronic, optoelectronic, or mechanical nanoscale devices a detailed understanding of their structural properties and in particular the strain state within their active region is of utmost importance. We demonstrate that X-ray nanodiffraction represents an excellent tool to investigate the internal structure of such devices in a nondestructive way by using a focused synchotron X-ray beam with a diameter of 400 nm. We show results on the strain fields in and around a single SiGe island, which serves as stressor for the Si-channel in a fully functioning Si-metal-oxide semiconductor field-effect transistor

    Collective dynamics of liquid aluminum probed by Inelastic X-ray Scattering

    Full text link
    An inelastic X-ray scattering experiment has been performed in liquid aluminum with the purpose of studying the collective excitations at wavevectors below the first sharp diffraction peak. The high instrumental resolution (up to 1.5 meV) allows an accurate investigation of the dynamical processes in this liquid metal on the basis of a generalized hydrodynamics framework. The outcoming results confirm the presence of a viscosity relaxation scenario ruled by a two timescale mechanism, as recently found in liquid lithium.Comment: 8 pages, 7 figure
    corecore