1,043 research outputs found

    The Royal College of Ophthalmologists' National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications.

    Get PDF
    Aim To describe the outcomes of cataract surgery in the United Kingdom. Methods Anonymised data on 180 114 eyes from 127 685 patients undergoing cataract surgery between August 2006 and November 2010 were collected prospectively from 28 sites. Outcome measures included intraoperative and postoperative complication rates, and preoperative and postoperative visual acuities. Results Median age at first eye surgery was 77.1 years, 36.9% cases had ocular co-pathology and 41.0% patients underwent cataract surgery on both eyes. Preoperative visual acuity was 0.30 logMAR or better in 32.0% first eyes and 47.7% second eyes. Postoperative best-measured visual acuity was 0.00 and 0.30 logMAR or better in 50.8 and 94.6% eyes without ocular co-pathology, and 32.5 and 79.9% in eyes with co-pathology. For eyes without co-pathology, postoperative uncorrected distance visual acuity was 0.00 and 0.30 logMAR or better in 27.3 and 80.9% eyes. Posterior capsule rupture or vitreous loss or both occurred in 1.95% cases, and was associated with a 42 times higher risk of retinal detachment surgery within 3 months and an eight times higher risk of endophthalmitis. Conclusion These results provide updated data for the benchmarking of cataract surgery. Visual outcomes, and the rate of posterior capsule rupture or vitreous loss or both appear stable over the past decade

    Particulate Air Pollution, Oxidative Stress Genes, and Heart Rate Variability in an Elderly Cohort

    Get PDF
    Background and Objectives: We have previously shown that reduced defenses against oxidative stress due to glutathione S-transferase M1 (GSTM1) deletion modify the effects of PM[2.5] (fine-particulate air pollution of < 2.5 μm in aerodynamic diameter) on heart rate variability (HRV) in a cross-sectional analysis of the Normative Aging Study, an elderly cohort. We have extended this to include a longitudinal analysis with more subjects and examination of the GT short tandem repeat polymorphism in the heme oxygenase-1 (HMOX-1) promoter. Methods: HRV measurements were taken on 539 subjects. Linear mixed effects models were fit for the logarithm of HRV metrics—including standard deviation of normal-to-normal intervals (SDNN), high frequency (HF), and low frequency (LF)—and PM2.5 concentrations in the 48 hr preceding HRV measurement, controlling for confounders and a random subject effect. Results: PM2.5 was significantly associated with SDNN (p = 0.04) and HF (p = 0.03) in all subjects. There was no association in subjects with GSTM1, whereas there was a significant association with SDNN, HF, and LF in subjects with the deletion. Similarly, there was no association with any HRV measure in subjects with the short repeat variant of HMOX-1, and significant associations in subjects with any long repeat. We found a significant three-way interaction of PM[2.5] with GSTM1 and HMOX-1 determining SDNN (p = 0.008), HF (p = 0.01) and LF (p = 0.04). In subjects with the GSTM1 deletion and the HMOX-1 long repeat, SDNN decreased by 13% [95% confidence interval (CI), −21% to −4%], HF decreased by 28% (95% CI, −43% to −9%), and LF decreased by 20% (95% CI, −35% to −3%) per 10 μg/m3 increase in PM. Conclusions: Oxidative stress is an important pathway for the autonomic effects of particles

    The Royal College of Ophthalmologists’ Glaucoma Commissioning Guidance: executive summary

    Get PDF
    The Royal College of Ophthalmologists (RCOphth) have recently published a commissioning guide for glaucoma care and this article is a summary of the key components of the guideline. This guidance applies to commissioning services for adult-onset glaucoma and adults who are at risk of developing glaucoma but does not apply to paediatric and juvenile glaucoma

    Primary trabeculectomy versus primary glaucoma eye drops for newly diagnosed advanced glaucoma: TAGS RCT

    Get PDF
    Background: Patients diagnosed with advanced primary open-angle glaucoma are at a high risk of lifetime blindness. Uncertainty exists about whether primary medical management (glaucoma eye drops) or primary surgical treatment (augmented trabeculectomy) provide the best and safest patient outcomes. // Objectives: To compare primary medical management with primary surgical treatment (augmented trabeculectomy) in patients with primary open-angle glaucoma presenting with advanced disease in terms of health-related quality of life, clinical effectiveness, safety and cost-effectiveness. // Design: This was a two-arm, parallel, multicentre, pragmatic randomised controlled trial. // Setting: Secondary care eye services. // Participants: Adult patients presenting with advanced primary open-angle glaucoma in at least one eye, as defined by the Hodapp–Parrish–Anderson classification of severe glaucoma. // Intervention: Primary medical treatment – escalating medical management with glaucoma eye drops. Primary trabeculectomy treatment – trabeculectomy augmented with mitomycin C. // Main outcome measures: The primary outcome was health-related quality of life measured with the Visual Function Questionnaire-25 at 2 years post randomisation. Secondary outcomes were mean intraocular pressure; EQ-5D-5L; Health Utilities Index 3; Glaucoma Utility Index; cost and cost-effectiveness; generic, vision-specific and disease-specific health-related quality of life; clinical effectiveness; and safety. // Results: A total of 453 participants were recruited. The mean age of the participants was 67 years (standard deviation 12 years) in the trabeculectomy arm and 68 years (standard deviation 12 years) in the medical management arm. Over 65% of participants were male and more than 80% were white. At 24 months, the mean difference in Visual Function Questionnaire-25 score was 1.06 (95% confidence interval –1.32 to 3.43; p = 0.383). There was no evidence of a difference between arms in the EQ-5D-5L score, the Health Utilities Index or the Glaucoma Utility Index. At 24 months, the mean intraocular pressure was 12.40 mmHg in the trabeculectomy arm and 15.07 mmHg in the medical management arm (mean difference –2.75 mmHg, 95% confidence interval –3.84 to –1.66 mmHg; p < 0.001). Fewer types of glaucoma eye drops were required in the trabeculectomy arm. LogMAR visual acuity was slightly better in the medical management arm (mean difference 0.07, 95% confidence interval 0.02 to 0.11; p = 0.006) than in the trabeculectomy arm. There was no evidence of difference in safety between the two arms. A discrete choice experiment updated the utility values for the Glaucoma Utility Index. The within-trial economic analysis found a small increase in the mean EQ-5D-5L score (0.04) and that trabeculectomy has a higher probability of being cost-effective than medical management. The incremental cost of trabeculectomy per quality-adjusted life-year was £45,456. Therefore, at 2 years, surgery is unlikely to be considered cost-effective at a threshold of £20,000 per quality-adjusted life-year. When extrapolated over a patient’s lifetime in a model-based analysis, trabeculectomy, compared with medical treatment, was associated with higher costs (average £2687), a larger number of quality-adjusted life-years (average 0.28) and higher incremental cost per quality-adjusted life-year gained (average £9679). The likelihood of trabeculectomy being cost-effective at a willingness-to-pay threshold of £20,000 per quality-adjusted life year gained was 73%. // Conclusions: Our results suggested that there was no difference between treatment arms in health-related quality of life, as measured with the Visual Function Questionnaire-25 at 24 months. Intraocular pressure was better controlled in the trabeculectomy arm, and this may reduce visual field progression. Modelling over the patient’s lifetime suggests that trabeculectomy may be cost-effective over the range of values of society’s willingness to pay for a quality-adjusted life-year

    The cubicle warrior: the marionette of the digitalized warfare

    Get PDF
    In the last decade we have entered the era of remote controlled military technology. The excitement about this new technology should not mask the ethical questions that it raises. A fundamental ethical question is who may be held responsible for civilian deaths. In this paper we will discuss the role of the human operator or so-called ‘cubicle warrior’, who remotely controls the military robots behind visual interfaces. We will argue that the socio-technical system conditions the cubicle warrior to dehumanize the enemy. As a result the cubicle warrior is morally disengaged from his destructive and lethal actions. This challenges what he should know to make responsible decisions (the so-called knowledge condition). Nowadays and in the near future, three factors will influence and may increase the moral disengagement even further due to the decrease of locus of control orientation: (1) photo shopping the war; (2) the moralization of technology; (3) the speed of decision-making. As a result, cubicle warriors cannot be held reasonably responsible anymore for the decisions they make

    A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance

    Get PDF
    BACKGROUND: The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. METHODS: An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 μm and 3000 μm diameters) were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals). RESULTS: The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute differences between the digital and stereo gradings 2 were 2.8 +/- 3.4% in the central subfield and 2.2 +/- 2.7% in the middle subfield. CONCLUSIONS: Semi-automated, supervised drusen measurements may be done reproducibly and accurately with adaptations of commercial software. This technique for macular image analysis has potential for use in clinical research

    Effects of an attention demanding task on dynamic stability during treadmill walking

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>People exhibit increased difficulty balancing when they perform secondary attention-distracting tasks while walking. However, a previous study by Grabiner and Troy (<it>J. Neuroengineering Rehabil</it>., 2005) found that young healthy subjects performing a concurrent Stroop task while walking on a motorized treadmill exhibited <it>decreased </it>step width variability. However, measures of variability do not directly quantify how a system responds to perturbations. This study re-analyzed data from Grabiner and Troy 2005 to determine if performing the concurrent Stroop task directly affected the dynamic stability of walking in these same subjects.</p> <p>Methods</p> <p>Thirteen healthy volunteers walked on a motorized treadmill at their self-selected constant speed for 10 minutes both while performing the Stroop test and during undisturbed walking. This Stroop test consisted of projecting images of the name of one color, printed in text of a different color, onto a wall and asking subjects to verbally identify the color of the text. Three-dimensional motions of a marker attached to the base of the neck (C5/T1) were recorded. Marker velocities were calculated over 3 equal intervals of 200 sec each in each direction. Mean variability was calculated for each time series as the average standard deviation across all strides. Both "local" and "orbital" dynamic stability were quantified for each time series using previously established methods. These measures directly quantify how quickly small perturbations grow or decay, either continuously in real time (local) or discretely from one cycle to the next (orbital). Differences between Stroop and Control trials were evaluated using a 2-factor repeated measures ANOVA.</p> <p>Results</p> <p>Mean variability of trunk movements was significantly reduced during the Stroop tests compared to normal walking. Conversely, local and orbital stability results were mixed: some measures showed slight increases, while others showed slight decreases. In many cases, different subjects responded differently to the Stroop test. While some of our comparisons reached statistical significance, many did not. In general, measures of variability and dynamic stability reflected different properties of walking dynamics, consistent with previous findings.</p> <p>Conclusion</p> <p>These findings demonstrate that the decreased movement variability associated with the Stroop task did <it>not </it>translate to greater dynamic stability.</p

    High blood pressure, antihypertensive medication and lung function in a general adult population

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Several studies showed that blood pressure and lung function are associated. Additionally, a potential effect of antihypertensive medication, especially beta-blockers, on lung function has been discussed. However, side effects of beta-blockers have been investigated mainly in patients with already reduced lung function. Thus, aim of this analysis is to determine whether hypertension and antihypertensive medication have an adverse effect on lung function in a general adult population.</p> <p>Methods</p> <p>Within the population-based KORA F4 study 1319 adults aged 40-65 years performed lung function tests and blood pressure measurements. Additionally, information on anthropometric measurements, medical history and use of antihypertensive medication was available. Multivariable regression models were applied to study the association between blood pressure, antihypertensive medication and lung function.</p> <p>Results</p> <p>High blood pressure as well as antihypertensive medication were associated with lower forced expiratory volume in one second (p = 0.02 respectively p = 0.05; R<sup>2</sup>: 0.65) and forced vital capacity values (p = 0.01 respectively p = 0.05, R<sup>2</sup>: 0.73). Furthermore, a detailed analysis of antihypertensive medication pointed out that only the use of beta-blockers was associated with reduced lung function, whereas other antihypertensive medication had no effect on lung function. The adverse effect of beta-blockers was significant for forced vital capacity (p = 0.04; R<sup>2</sup>: 0.65), while the association with forced expiratory volume in one second showed a trend toward significance (p = 0.07; R<sup>2</sup>: 0.73). In the same model high blood pressure was associated with reduced forced vital capacity (p = 0.01) and forced expiratory volume in one second (p = 0.03) values, too.</p> <p>Conclusion</p> <p>Our analysis indicates that both high blood pressure and the use of beta-blockers, but not the use of other antihypertensive medication, are associated with reduced lung function in a general adult population.</p
    corecore