11 research outputs found
The peppermint breath test benchmark for PTR-MS and SIFT-MS
18openInternationalInternational coauthor/editorA major challenge for breath research is the lack of standardization in sampling and analysis. To address this, a test that utilizes a standardized intervention and a defined study protocol has been proposed to explore disparities in breath research across different analytical platforms and to provide benchmark values for comparison. Specifically, the Peppermint Experiment involves the targeted analysis in exhaled breath of volatile constituents of peppermint oil after ingestion of the encapsulated oil. Data from the Peppermint Experiment performed by proton transfer reaction mass spectrometry (PTR-MS) and selected ion flow tube mass spectrometry (SIFT-MS) are presented and discussed herein, including the product ions associated with the key peppermint volatiles, namely limonene, α- and β-pinene, 1,8-cineole, menthol, menthone and menthofuran. The breath washout profiles of these compounds from 65 individuals were collected, comprising datasets from five PTR-MS and two SIFT-MS instruments. The washout profiles of these volatiles were evaluated by comparing the log-fold change over time of the product ion intensities associated with each volatile. Benchmark values were calculated from the lower 95% confidence interval of the linear time-to-washout regression analysis for all datasets combined. Benchmark washout values from PTR-MS analysis were 353 min for the sum of monoterpenes and 1,8-cineole (identical product ions), 173 min for menthol, 330 min for menthofuran, and 218 min for menthone; from SIFT-MS analysis values were 228 min for the sum of monoterpenes, 281 min for the sum of monoterpenes and 1,8-cineole, and 370 min for menthone plus 1,8-cineole. Large inter- and intra-dataset variations were observed, whereby the latter suggests that biological variability plays a key role in how the compounds are absorbed, metabolized and excreted from the body via breath. This variability seems large compared to the influence of sampling and analytical procedures, but further investigations are recommended to clarify the effects of these factors.openHenderson, Ben; Slingers, Gitte; Pedrotti, Michele; Pugliese, Giovanni; Malásková, Michaela; Bryant, Luke; Lomonaco, Tommaso; Ghimenti, Silvia; Moreno, Sergi; Cordell, Rebecca; Harren, Frans J M; Schubert, Jochen; Mayhew, Chris A; Wilde, Michael; Di Francesco, Fabio; Koppen, Gudrun; Beauchamp, Jonathan D; Cristescu, Simona MHenderson, B.; Slingers, G.; Pedrotti, M.; Pugliese, G.; Malásková, M.; Bryant, L.; Lomonaco, T.; Ghimenti, S.; Moreno, S.; Cordell, R.; Harren, F.J.M.; Schubert, J.; Mayhew, C.A.; Wilde, M.; Di Francesco, F.; Koppen, G.; Beauchamp, J.D.; Cristescu, S.M
The peppermint breath test benchmark for PTR-MS and SIFT-MS
Contains fulltext :
237394.pdf (Publisher’s version ) (Open Access
Exhaled breath metabolomics reveals a pathogen-specific response in a rat pneumonia model for two human pathogenic bacteria: A proof-of-concept study
Volatile organic compounds in breath can reflect host and pathogen metabolism and might be used to diagnose pneumonia. We hypothesized that rats with Streptococcus pneumoniae (SP) or Pseudomonas aeruginosa (PA) pneumonia can be discriminated from uninfected controls by thermal desorption-gas chromatography- mass-spectrometry (TD-GC-MS) and selected ion flow tubemass spectrometry (SIFT-MS) of exhaled breath. Male adult rats (n = 50) received an intratracheal inoculation of 1) 200 µl saline, or 2) 1 × 107 colony-forming units of SP or 3) 1 × 107 CFU of PA. Twenty-four hours later the rats were anaesthetized, tracheotomized, and mechanically ventilated. Exhaled breath was analyzed via TDGC- MS and SIFT-MS. Area under the receiver operating characteristic curves (AUROCCs) and correct classification rate (CCRs) were calculated after leave-one-out cross-validation of sparse partial least squares-discriminant analysis. Analysis of GC-MS data showed an AUROCC (95% confidence interval) of 0.85 (0.73- 0.96) and CCR of 94.6% for infected versus noninfected animals, AUROCC of 0.98 (0.94 -1) and CCR of 99.9% for SP versus PA, 0.92 (0.83-1.00), CCR of 98.1% for SP versus controls and 0.97 (0.92-1.00), and CCR of 99.9% for PA versus controls. For these comparisons the SIFT-MS data showed AUROCCs of 0.54, 0.89, 0.63, and 0.79, respectively. Exhaled breath analysis discriminated between respiratory infection and no infection but with even better accuracy between specific pathogens. Future clinical studies should not only focus on the presence of respiratory infection but also on the discrimination between specific pathogens
Exhaled breath metabolomics reveals a pathogen-specific response in a rat pneumonia model for two human pathogenic bacteria:a proof-of-concept study
Volatile organic compounds in breath can reflect host and pathogen metabolism and might be used to diagnose pneumonia. We hypothesized that rats with Streptococcus pneumoniae (SP) or Pseudomonas aeruginosa (PA) pneumonia can be discriminated from uninfected controls by thermal desorption-gas chromatography-mass-spectrometry (TD-GC-MS) and selected ion flow tube-mass spectrometry (SIFT-MS) of exhaled breath. Male adult rats (n = 50) received an intratracheal inoculation of 1) 200 µl saline, or 2) 1 × 107 colony-forming units of SP or 3) 1 × 107 CFU of PA. Twenty-four hours later the rats were anaesthetized, tracheotomized, and mechanically ventilated. Exhaled breath was analyzed via TD-GC-MS and SIFT-MS. Area under the receiver operating characteristic curves (AUROCCs) and correct classification rate (CCRs) were calculated after leave-one-out cross-validation of sparse partial least squares-discriminant analysis. Analysis of GC-MS data showed an AUROCC (95% confidence interval) of 0.85 (0.73-0.96) and CCR of 94.6% for infected versus noninfected animals, AUROCC of 0.98 (0.94-1) and CCR of 99.9% for SP versus PA, 0.92 (0.83-1.00), CCR of 98.1% for SP versus controls and 0.97 (0.92-1.00), and CCR of 99.9% for PA versus controls. For these comparisons the SIFT-MS data showed AUROCCs of 0.54, 0.89, 0.63, and 0.79, respectively. Exhaled breath analysis discriminated between respiratory infection and no infection but with even better accuracy between specific pathogens. Future clinical studies should not only focus on the presence of respiratory infection but also on the discrimination between specific pathogens
A benchmarking protocol for breath analysis: The peppermint experiment
International audienceSampling of volatile organic compounds (VOCs) has shown promise for detection of a range of diseases but results have proved hard to replicate due to a lack of standardization. In this work we introduce the 'Peppermint Initiative'. The initiative seeks to disseminate a standardized experiment that allows comparison of breath sampling and data analysis methods. Further, it seeks to share a set of benchmark values for the measurement of VOCs in breath. Pilot data are presented to illustrate the standardized approach to the interpretation of results obtained from the Peppermint experiment. This pilot study was conducted to determine the washout profile of peppermint compounds in breath, identify appropriate sampling time points, and formalise the data analysis. Five and ten participants were recruited to undertake a standardized intervention by ingesting a peppermint oil capsule that engenders a predictable and controlled change in the VOC profile in exhaled breath. After collecting a pre-ingestion breath sample, five further samples are taken at 2, 4, 6, 8, and 10 h after ingestion. Samples were analysed using ion mobility spectrometry coupled to multi-capillary column and thermal desorption gas chromatography mass spectrometry. A regression analysis of the washout data was used to determine sampling times for the final peppermint protocol, and the time for the compound measurement to return to baseline levels was selected as a benchmark value. A measure of the quality of the data generated from a given technique is proposed by comparing data fidelity. This study protocol has been used for all subsequent measurements by the Peppermint Consortium (16 partners from seven countries). So far 1200 breath samples from 200 participants using a range of sampling and analytical techniques have been collected. The data from the consortium will be disseminated in subsequent technical notes focussing on results from individual platforms