138 research outputs found

    The 30/20 GHz communications system functional requirements

    Get PDF
    The characteristics of 30/20 GHz usage in satellite systems to be used in support of projected communication requirements of the 1990's are defined. A requirements analysis which develops projected market demand for satellite services by general and specialized carriers and an analysis of the impact of propagation and system constraints on 30/20 GHz operation are included. A set of technical performance characteristics for the 30/20 GHz systems which can serve the resulting market demand and the experimental program necessary to verify technical and operational aspects of the proposed systems is also discussed

    Planning assistance for the 30/20 GHz program, volume 1

    Get PDF
    Functional requirements for the 30/20 GHz communication system, planning assistance for the 30/20 GHz program, and a review of specified conceptual designs and recommendations are provided

    Planning assistance for the 30/20 GHz program, volume 3

    Get PDF
    The three basic experiment categories and consolidated experiments proposed by members of the Carrier Working Group are defined by category and by carrier. The three experiment categories are: (1) Possible Service (PS); (2) Possible Service and Technology (PSAT); and (3) Possible Technology (PT). Under Task 9 Western Union provided review, recommendations and critique of the NASA generated Statement of Work (SOW) defining the technical requirements governing design, launch and operation of the 30/20 GHz experimental systems

    In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

    Get PDF
    The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed

    Mixed-valent ruthenium oxide - ruthenium cyanide inorganic film on glassy carbon electrodes as an amperometric sensor of aliphatic alcohols

    Get PDF
    A mixed-valent ruthenium oxide-ruthenium cyanide film on glassy carbon (GC/mvRuO-RuCN) electrode exhibits excellent electrocatalytic activity toward oxidation of simple aliphatic alcohols and polyhydric compounds in acidic media. Electrochemical formation of the ruthenium oxide-based chemically modified electrode can be accomplished by potential cycling or potentiostatic control in diluted sulfuric acid solutions. The attractive electrooxidation capabilities of hydroxyl-containing compounds at this modified electrode are highlighted in terms of sensitivity, stability, and catalytic action. Remarkably, the molar response of the catalytic oxidation increases on increasing the chain length of aliphatic alcohols. For example, the molar response ratio between 1-butanol and methanol is 37 in 25 mM sulfuric acid. Chromatographic separations with electrochemical detection using the GC/mvRuO-RuCN modified electrode allo rr very simple quantitation of aliphatic alcohols in real samples with linear calibration plots over about 3 orders of magnitude. The detection limits for ethanol, 1-propanol, 1-butanol, and 1-pentanol are 4, 0.8, 1, and 2 nmol injected (S/N = 3), respectively

    A Model for the Ultrastructure of Bone Based on Electron Microscopy of Ion-Milled Sections

    Get PDF
    The relationship between the mineral component of bone and associated collagen has been a matter of continued dispute. We use transmission electron microscopy (TEM) of cryogenically ion milled sections of fully-mineralized cortical bone to study the spatial and topological relationship between mineral and collagen. We observe that hydroxyapatite (HA) occurs largely as elongated plate-like structures which are external to and oriented parallel to the collagen fibrils. Dark field images suggest that the structures (“mineral structures”) are polycrystalline. They are approximately 5 nm thick, 70 nm wide and several hundred nm long. Using energy-dispersive X-ray analysis we show that approximately 70% of the HA occurs as mineral structures external to the fibrils. The remainder is found constrained to the gap zones. Comparative studies of other species suggest that this structural motif is ubiquitous in all vertebrates
    • …
    corecore