12 research outputs found

    Use of particulate surrogates for assessing microbial mobility in subsurface ecosystems

    Get PDF
    Mass fluxes from the ground surface can play a vital role in influencing groundwater ecosystems. Rates of delivery may influence intact ecosystem composition, while fluxes of substances associated with anthropogenic activity may critically alter the functioning of associated microbial assemblages. Field-based tracing experiments offer a valuable means of understanding mass transport rates and mechanisms, particularly in complex heterogeneous epikarst systems overlying vulnerable fissured aquifers. A short-term tracer experiment monitoring solute and particle tracer concentrations after they passed through a 10-m-thick sequence of limestone, capped by a thin soil, revealed rapid travel times and variable attenuation rates for the substances employed. Results demonstrated that particle tracers have shorter average travel times and can reach the subsurface in higher concentrations and over shorter times than non-reactive solutes. High recovery rates for the bacterial tracer Ralstonia eutropha H16 contrasted strongly with those of similarly sized fluorescent polystyrene microspheres, highlighting the importance of physico-chemical surface characteristics of particle tracers. Complementary laboratory batch experiments examined the role played by organic and inorganic soil/rock surfaces on particle tracer attenuation. Findings suggest that biofilms may significantly promote transport of particulate material below ground, i.e., the delivery of allochthonous microorganisms to karst groundwate

    Groundwater protection in fractured media: a vulnerability-based approach for delineating protection zones in Switzerland

    Get PDF
    A vulnerability-based approach for delineating groundwater protection zones around springs in fractured media has been developed to implement Swiss water-protection regulations. It takes into consideration the diversity of hydrogeological conditions observed in fractured aquifers and provides individual solutions for each type of setting. A decision process allows for selecting one of three methods, depending on the spring vulnerability and the heterogeneity of the aquifer. At the first stage, an evaluation of spring vulnerability is required, which is essentially based on spring hydrographs and groundwater quality monitoring. In case of a low vulnerability of the spring, a simplified method using a fixed radius approach ("distance method”) is applied. For vulnerable springs, additional investigations must be completed during a second stage to better characterize the aquifer properties, especially in terms of heterogeneity. This second stage includes a detailed hydrogeological survey and tracer testing. If the aquifer is assessed as slightly heterogeneous, the delineation of protection zones is performed using a calculated radius approach based on tracer test results ("isochrone method”). If the heterogeneity is high, a groundwater vulnerability mapping method is applied ("DISCO method”), based on evaluating discontinuities, protective cover and runoff parameters. Each method is illustrated by a case stud

    Characterisation of virus transport and attenuation in epikarst using short pulse and prolonged injection multi-tracer testing

    No full text
    Attenuation processes controlling virus fate and transport in the vadose zone of karstified systems can strongly influence groundwater quality. This research compares the breakthrough of two bacteriophage tracers (H40/1 and T7), with contrasting properties, at subsurface monitoring points following application onto an overlying composite sequence of thin organic soil and weathered limestone (epikarst). Short pulse multi-tracer test results revealed that T7 (Source concentration, Co = 1.8 Ă— 106 pfu/mL) and H40/1 (Co = 5.9 Ă— 106 pfu/mL) could reach sampling points 10 m below ground less than 30 min after tracer application. Contrasting deposition rates, determined from simulated tracer responses, reflected the potential of the ground to differentially attenuate viruses. Prolonged application of both T7 (Co = 2.3 Ă— 104 pfu/mL) and H40/1 (Co = 1.3 Ă— 105 pfu/mL) over a five hour period during a subsequent test, in which ionic strength levels observed at monitoring points rose consistently, corresponded to a rapid rise in T7 levels, followed by a gradual decline before the end of tracer injection; this reflected reaction-limited deposition in the system. T7\u27s response contrasted with that of H40/1, whose concentration remained constant over a three hour period before declining dramatically prior to the end of tracer injection. Subsequent application of lower ionic strength tracer-free flush water generated a rapid rise in H40/1 levels and a more gradual release of T7. Results highlight the benefits of employing prolonged injection multi-tracer tests for identifying processes not apparent from conventional short pulse tests. Study findings demonstrate that despite rapid transport rates, the epikarst is capable of physicochemical filtration of viruses and their remobilization, depending on virus type and hydrochemical conditions
    corecore