12 research outputs found
Heritability of Coronary Artery Disease: Insights From a Classical Twin Study
Genetics have a strong influence on calcified atherosclerotic plaques; however, data regarding the heritability of noncalcified plaque volume are scarce. We aimed to evaluate genetic versus environmental influences on calcium (coronary artery calcification) score, noncalcified and calcified plaque volumes by coronary computed tomography angiography in adult twin pairs without known coronary artery disease. METHODS: In the prospective BUDAPEST-GLOBAL (Burden of Atherosclerotic Plaques Study in Twins—Genetic Loci and the Burden of Atherosclerotic Lesions) classical twin study, we analyzed twin pairs without known coronary artery disease. All twins underwent coronary computed tomography angiography to assess coronary atherosclerotic plaque volumes. Structural equation models were used to quantify the contribution of additive genetic, common environmental, and unique environmental components to plaque volumes adjusted for age, gender, or atherosclerotic cardiovascular disease risk estimate and statin use. RESULTS: We included 196 twins (mean age±SD, 56±9 years, 63.3% females), 120 monozygotic and 76 same-gender dizygotic pairs. Using structural equation models, noncalcified plaque volume was predominantly determined by environmental factors (common environment, 63% [95% CI, 56%–67%], unique environment, 37% [95% CI, 33%–44%]), while coronary artery calcification score and calcified plaque volumes had a relatively strong genetic heritability (additive genetic, 58% [95% CI, 50%–66%]; unique environmental, 42% [95% CI, 34%–50%] and additive genetic, 78% [95% CI, 73%–80%]; unique environmental, 22% [95% CI, 20%–27%]), respectively. CONCLUSIONS: Noncalcified plaque volume is mainly influenced by shared environmental factors, whereas coronary artery calcification score and calcified plaque volume are more determined by genetics. These findings emphasize the importance of early lifestyle interventions in preventing coronary plaque formation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01738828
A fotonszámláló detektoros CT működési alapelve, előnyei és jelentősége a klinikai gyakorlatban = Photoncounting-detector CT: Basic principles, advantages and implications in clinical practice
Az elmúlt évtizedben fizikai és preklinikai vizsgálatokkal igazolták az alapjaiban új típusú, fotonszámláló komputertomográfiás (CT) detektor kiváló
képalkotási tulajdonságait, míg napjainkban a páréves klinikai felhasználás egyre szélesebb körű tapasztalatait veszik számba.
A klinikai gyakorlatban elterjedt, hagyományos CT-berendezésekben energiaintegráló detektorok (EID) találhatók, melyek indirekt konverziós technológiával alakítják át a röntgenfotonok energiáját elektromos jellé. Ezzel
ellentétben a fotonszámláló CT detektorai (PCD) közvetlenül és magasabb
hatásfokkal képesek elektromos jellé alakítani a röntgenfotonok energiáját, megszámlálni az egyes röntgenfotonok által létrehozott töltéseket és
mérni azok energiaszintjét.
Az új PCD-technológia számos előnyt nyújt a hagyományos EID-technológiával összevetve: egyrészt kisebb sugárterhelés mellett jobb térbeli felbontású,
kedvezőbb jel/zaj arányú, kevesebb sugárkeményedési („beam-hardening”)
műterméket tartalmazó és alacsonyabb elektronikus zajjal terhelt CT-képeket hoz létre, másrészt lehetővé teszi a spektrális képalkotást, valamint
csökkentett dózisú kontrasztanyag alkalmazására is lehetőséget ad.
Összefoglaló közleményünk a PCD-CT műszaki és fizikai alapelveit ismerteti, valamint áttekintést nyújt annak előnyeiről és a klinikai gyakorlatban
való felhasználásáról. | Over the last decade, an esentially new type of computed tomography (CT)
detector, namely the photoncounting detector has demonstrated its superior capabilities over traditional CT detectors in both physical and preclinical evaluations, while is now at the stage of early clinical experiences.
Conventional CT scanners available today for routine clinical practice use
energy integrated detectors (EID) which rely on indirect conversion technology. In contrary, the newly-introduced photon-counting detectors (PCD)
utilize a direct conversion method allowing to count the number of x-ray
photons and carry detailed information about the energy level of each individual x-ray photon.
Due to the fundamental changes in the physical mechanisms responsible for photon detection and signal creation, PCDs have several benefits over traditional CT detectors. In comparison to current CT technology, PCDCT can produce better spatial resolution, reduced electronic noise with a
higher contrast-to-noise ratio, reduced beam-hardening and metal artifacts. Furthermore, from the spectral information, this new technology is
capable to reconstruct virtual monoenergetic images and optimize iv. contrast agent dose.
In our current review article, technical principles and physics of PCDs and,
in addition, early clinical experiences with their applications are summarized
Left atrial appendage size is a marker of atrial fibrillation recurrence after radiofrequency catheter ablation in patients with persistent atrial fibrillation
Introduction There are no consistently confirmed predictors of atrial fibrillation (AF) recurrence after catheter ablation. Therefore, we aimed to study whether left atrial appendage volume (LAAV) and function influence the long-term recurrence of AF after catheter ablation, depending on AF type.Methods AF patients who underwent point-by-point radiofrequency catheter ablation after cardiac computed tomography (CT) were included in this analysis. LAAV and LAA orifice area were measured by CT. Uni- and multivariable Cox proportional hazard regression models were performed to determine the predictors of AF recurrence.Results In total, 561 AF patients (61.9 +/- 10.2 years, 34.9% females) were included in the study. Recurrence of AF was detected in 40.8% of the cases (34.6% in patients with paroxysmal and 53.5% in those with persistent AF) with a median recurrence-free time of 22.7 (9.3-43.1) months. Patients with persistent AF had significantly higher body surface area-indexed LAV, LAAV, and LAA orifice area and lower LAA flow velocity, than those with paroxysmal AF. After adjustment left ventricular ejection fraction (LVEF) Conclusion The current study demonstrates that beyond left ventricular systolic dysfunction, LAA enlargement is associated with higher rate of AF recurrence after catheter ablation in persistent AF, but not in patients with paroxysmal AF.</p
Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world
Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic.
Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality.
Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States.
Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis.
Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
The Management of COVID-19-Related Coagulopathy: A Focus on the Challenges of Metabolic and Vascular Diseases
The course of COVID-19 is highly dependent on the associated cardiometabolic comorbidities of the patient, which worsen the prognosis of coronavirus infection, mainly due to systemic inflammation, endothelium dysfunction, and thrombosis. A search on the recent medical literature was performed in five languages, using the PubMed, Embase, Cochrane, and Google Scholar databases, for the review of data regarding the management of patients with a high risk for severe COVID-19, focusing on the associated coagulopathy. Special features of COVID-19 management are presented, based on the underlying conditions (obesity, diabetes mellitus, and cardiovascular diseases), emphasizing the necessity of a modern, holistic approach to thromboembolic states. The latest findings regarding the most efficient therapeutic approaches are included in the article, offering guidance for medical professionals in severe, complicated cases of SARS-CoV-2 infection. We can conclude that severe COVID-19 is closely related to vascular inflammation and intense cytokine release leading to hemostasis disorders. Overweight, hyperglycemia, cardiovascular diseases, and old age are important risk factors for severe outcomes of coronavirus infection, involving a hypercoagulable state. Early diagnosis and proper therapy in complicated SARS-CoV-2-infected cases could reduce mortality and the need for intensive care during hospitalization in patients with cardiometabolic comorbidities
Outcomes of Redo Transcatheter Aortic Valve Replacement According to the Initial and Subsequent Valve Type
Background: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. Objectives: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. Methods: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). Results: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). Conclusions: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR