18 research outputs found

    Influence of the Ni-Co/Al-Mg catalyst loading in the continuous aqueous phase reforming of the bio-oil aqueous fraction

    Get PDF
    The effect of catalyst loading in the Aqueous Phase Reforming (APR) of bio-oil aqueous fraction has been studied with a Ni-Co/Al-Mg coprecipitated catalyst. Because of the high content of water in the bio-oil aqueous fraction, APR could be a useful process to convert this fraction into valuable products. Experiments of APR with continuous feeding of aqueous solution of acetol, butanol and acetic acid as the only compound, together with a simulated and a real aqueous fraction of bio-oil, were carried out. Liquid products in the liquid effluent of the APR model compounds were quantified and the reaction pathways were revised. The increase of catalyst loading produced an increase of gas production and a gas with higher alkanes content. Acetol was the compound with the highest reactivity while the conversion of acetic acid was very low. The presence of acetic acid in the feed caused catalyst deactivation

    Are Comorbidities Associated With Overall Survival in Patients With Oral Squamous Cell Carcinoma?

    Get PDF
    Purpose: Oral squamous cell carcinoma (OSCC) is a highly prevalent type of immunogenic cancer with a low survival rate in patients with comorbidities owing to toxic habits. Materials and Methods: A retrospective cohort study was conducted of patients with resectable OSCC at a tertiary Spanish hospital from 2011 to 2014. The primary predictor variables were comorbidity and immune biomarkers. Comorbidity was assessed using the Adult Comorbidity Evaluation–27 (ACE-27) and scored from 1 to 3 (mild to severe decompensation, respectively). The immune biomarkers were neutrophil-to-lymphocyte ratio (NLR), derived NLR (dNLR), platelet-to-lymphocyte ratio (PLR), and lymphocyte-to-monocyte ratio (LMR). The primary outcome variable was 5-year overall survival (OS). Other study variables were stage, margin, and neck management. Receiver operating characteristic curves were built for each ratio. For the survey of immune biomarkers, area under the curve was computed to determine cutoff points and investigate their association with OS. Kaplan-Meier estimates of survival and Cox proportional hazards models were used for longitudinal analysis. Results: Overall 215 patients were identified (median age, 67 yr; range, 32 to 96 yr; median follow-up, 31 months; range, 7 to 78 months); 159 patients had at least 1 comorbid condition. Results showed that a severe comorbidity (according to the ACE-27) increased the risk of death by 4 times in patients with OSCC regardless of stage. NLR, dNLR, LMR, and PLR were associated with OS in the univariate study. Cutoff points to predict increased mortality were 3, 1.9, 2.6, and 66 for NLR, dNLR, LMR, and PLR, respectively. Age, comorbidity, stage, margins, and management of the neck were important independent predictors of decreased OS in OSCC. PLR was marginally associated with OS in the multivariate model. Conclusion: These results suggest that comorbidity and NLR, dNLR, LMR, and PLR are associated with 5-year OS in patients with resectable OSCC

    Idoneidad del uso del MALDI-TOF MS para la identificación de Staphylococcus aureus y miembros del grupo de Staphylococcus intermedius (S.I.G.)

    Get PDF
    A pesar de que el género Staphylococcus es comúnmente aislado en humanos y animales, su identificación sigue siendo problemática. Este estudio evalúa la idoneidad del MALDI-TOF MS (Biotyper 3) para su identificación, comparando los resultados obtenidos mediante diferentes métodos: fenotípicos, MALDITOF MS (añadiendo o no ácido fórmico) y moleculares. Una colección de 37 cepas fue identificada por técnicas convencionales como S. aureus (n= 7), S. intermedius (n=1) y S. pseudintermedius (n=29). Los aislamientos provenían de perros, tanto sanos como enfermos (n=27), y humanos (n=10), a partir de diferentes muestras biológicas. Todas ellas fueron también identificadas por biología molecular y los cultivos puros fueron procesados en el MALDI-TOF MS. La información fue analizada con DAG_Stat. La sensibilidad, especificidad, eficiencia y el índice kappa se estimaron para cada especie bacteriana con un nivel de confianza del 95%, tomando la biología molecular como gold standard. Se detectaron Estafilococos de 27 perros y de sus dueños. Solamente una cepa de S. intermedius fue aislada, así que los parámetros relacionados con ella tienen que ser considerados con cautela. Todos los S. aureus fueron identificados correctamente. Usando MALDI-TOF MS con ácido fórmico, hubo una concordancia casi perfecta entre pruebas en la identificación de S. aureus y S. pseudintermedius. Cuando no se añadía ácido fórmico, la concordancia fue perfecta para S. aureus, mientras que para S. pseudintermedius fue buena. Este trabajo demuestra la validez, la utilidad y la fiabilidad del MALDI-TOF MS para la identificación de aislamientos bacterianos pertenecientes a Staphylococcus spp

    Detection of norovirus in saliva samples from acute gastroenteritis cases and asymptomatic subjects : Association with age and higher shedding in stool

    Get PDF
    Norovirus infections are a leading cause of acute gastroenteritis outbreaks worldwide and across all age groups, with two main genogroups (GI and GII) infecting humans. The aim of our study was to investigate the occurrence of norovirus in saliva samples from individuals involved in outbreaks of acute gastroenteritis in closed and semiclosed institutions, and its relationship with the virus strain, virus shedding in stool, the occurrence of symptoms, age, and the secretor status of the individual. Epidemiological and clinical information was gathered from norovirus outbreaks occurring in Catalonia, Spain during 2017-2018, and stool and saliva samples were collected from affected and exposed resident individuals and workers. A total of 347 saliva specimens from 25 outbreaks were analyzed. Further, 84% of individuals also provided a paired stool sample. For GII infections, norovirus was detected in 17.9% of saliva samples from symptomatic cases and 5.2% of asymptomatic individuals. Positivity in saliva occurred in both secretors and nonsecretors. None of the individuals infected by norovirus GI was positive for the virus in saliva. Saliva positivity did not correlate with any of the studied symptoms but did correlate with age ≥ 65 years old. Individuals who were positive in saliva showed higher levels of virus shedding in stool. Mean viral load in positive saliva was 3.16 ± 1.08 log10 genome copies/mL, and the predominance of encapsidated genomes was confirmed by propidium monoazide (PMA)xx-viability RTqPCR assay. The detection of norovirus in saliva raises the possibility of oral-to-oral norovirus transmission during the symptomatic phase and, although to a lesser extent, even in cases of asymptomatic infections

    Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

    Get PDF
    The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be (38.1 ± 2.2 (stat.) ± 5.9 (syst.)) mBq/m3. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1 counts/yr in the neutrinoless double beta decay sample

    Electron drift properties in high pressure gaseous xenon

    Full text link
    [EN] Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and di¿usion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent ampli¿cation, a 1:2 scale model of the future NEXT-100detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December2016. The drift parameters have been measured using 83mKr for a range of reduced drift ¿elds at two di¿erent pressure regimes, namely 7.2 bar and 9.1 bar. Theresults have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal di¿usion and transverse di¿usion.The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.Simon, A.; Felkai, R.; Martinez-Lema, G.; Monrabal, F.; Gonzalez-Diaz, D.; Sorel, M.; Hernando Morata, JA.... (2018). Electron drift properties in high pressure gaseous xenon. Journal of Instrumentation. 13. https://doi.org/10.1088/1748-0221/13/07/P07013S13Nygren, D. (2009). High-pressure xenon gas electroluminescent TPC for 0-ν ββ-decay search. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 603(3), 337-348. doi:10.1016/j.nima.2009.01.222Gómez Cadenas, J. J., Álvarez, V., Borges, F. I. G., Cárcel, S., Castel, J., Cebrián, S., … Dias, T. H. V. T. (2014). Present Status and Future Perspectives of the NEXT Experiment. Advances in High Energy Physics, 2014, 1-22. doi:10.1155/2014/907067Martín-Albo, J., Muñoz Vidal, J., Ferrario, P., Nebot-Guinot, M., Gómez-Cadenas, J. J., … Cárcel, S. (2016). Sensitivity of NEXT-100 to neutrinoless double beta decay. Journal of High Energy Physics, 2016(5). doi:10.1007/jhep05(2016)159Álvarez, V., Borges, F. I. G., Cárcel, S., Castel, J., Cebrián, S., Cervera, A., … Díaz, J. (2013). Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. Journal of Instrumentation, 8(04), P04002-P04002. doi:10.1088/1748-0221/8/04/p04002Álvarez, V., Borges, F. I. G., Cárcel, S., Castel, J., Cebrián, S., Cervera, A., … Díaz, J. (2013). Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array. Journal of Instrumentation, 8(09), P09011-P09011. doi:10.1088/1748-0221/8/09/p09011Álvarez, V., Borges, F. I. G. M., Cárcel, S., Castel, J., Cebrián, S., Cervera, A., … Díaz, J. (2013). Near-intrinsic energy resolution for 30–662keV gamma rays in a high pressure xenon electroluminescent TPC. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 708, 101-114. doi:10.1016/j.nima.2012.12.123Ferrario, P., Laing, A., López-March, N., Gómez-Cadenas, J. J., Álvarez, V., … Cebrián, S. (2016). First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment. Journal of High Energy Physics, 2016(1). doi:10.1007/jhep01(2016)104Pack, J. L., Voshall, R. E., & Phelps, A. V. (1962). Drift Velocities of Slow Electrons in Krypton, Xenon, Deuterium, Carbon Monoxide, Carbon Dioxide, Water Vapor, Nitrous Oxide, and Ammonia. Physical Review, 127(6), 2084-2089. doi:10.1103/physrev.127.2084Pack, J. L., Voshall, R. E., Phelps, A. V., & Kline, L. E. (1992). Longitudinal electron diffusion coefficients in gases: Noble gases. Journal of Applied Physics, 71(11), 5363-5371. doi:10.1063/1.350555Bowe, J. C. (1960). Drift Velocity of Electrons in Nitrogen, Helium, Neon, Argon, Krypton, and Xenon. Physical Review, 117(6), 1411-1415. doi:10.1103/physrev.117.1411Patrick, E. L., Andrews, M. L., & Garscadden, A. (1991). Electron drift velocities in xenon and xenon‐nitrogen gas mixtures. Applied Physics Letters, 59(25), 3239-3240. doi:10.1063/1.105744English, W. N., & Hanna, G. C. (1953). GRID IONIZATION CHAMBER MEASUREMENTS OF ELECTRON DRIFT VELOCITIES IN GAS MIXTURES. Canadian Journal of Physics, 31(5), 768-797. doi:10.1139/p53-070Hunter, S. R., Carter, J. G., & Christophorou, L. G. (1988). Low-energy electron drift and scattering in krypton and xenon. Physical Review A, 38(11), 5539-5551. doi:10.1103/physreva.38.5539Kobayashi, S., Hasebe, N., Hosojima, T., Ishizaki, T., Iwamatsu, K., Mimura, M., … Ishizuka, A. (2006). Ratio of Transverse Diffusion Coefficient to Mobility of Electrons in High-Pressure Xenon and Xenon Doped with Hydrogen. Japanese Journal of Applied Physics, 45(10A), 7894-7900. doi:10.1143/jjap.45.7894Álvarez, V., Borges, F. I. G., Cárcel, S., Cebrián, S., Cervera, A., Conde, C. A. N., … Esteve, R. (2013). Ionization and scintillation response of high-pressure xenon gas to alpha particles. Journal of Instrumentation, 8(05), P05025-P05025. doi:10.1088/1748-0221/8/05/p05025Lorca, D., Martín-Albo, J., Laing, A., Ferrario, P., Gómez-Cadenas, J. J., Álvarez, V., … Cebrián, S. (2014). Characterisation of NEXT-DEMO using xenon KαX-rays. Journal of Instrumentation, 9(10), P10007-P10007. doi:10.1088/1748-0221/9/10/p10007Kusano, H., Lopes, J. A. M., Miyajima, M., & Hasebe, N. (2013). Longitudinal and transverse diffusion of electrons in high-pressure xenon. Journal of Instrumentation, 8(01), C01028-C01028. doi:10.1088/1748-0221/8/01/c01028Henriques, C. A. O., Freitas, E. D. C., Azevedo, C. D. R., González-Díaz, D., Mano, R. D. P., Jorge, M. R., … Álvarez, V. (2017). Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection. Physics Letters B, 773, 663-671. doi:10.1016/j.physletb.2017.09.017Obert, E. F. (1948). Compressibility Chart and the Ideal Reduced Volume. Industrial & Engineering Chemistry, 40(11), 2185-2186. doi:10.1021/ie50467a036Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., … Barrand, G. (2003). Geant4—a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 506(3), 250-303. doi:10.1016/s0168-9002(03)01368-8González-Díaz, D., Monrabal, F., & Murphy, S. (2018). Gaseous and dual-phase time projection chambers for imaging rare processes. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 878, 200-255. doi:10.1016/j.nima.2017.09.024Álvarez, V., Borges, F. I. G. M., Cárcel, S., Castel, J., Cebrián, S., Cervera, A., … Díaz, J. (2014). Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy γ-rays. Journal of Instrumentation, 9(04), C04015-C04015. doi:10.1088/1748-0221/9/04/c0401

    Radiopurity assessment of the energy readout for the NEXT double beta decay experiment

    Full text link
    [EN] The "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 × 10¿4 counts per keV, kg and year, satisfying the sensitivity requirements of the NEXT experiment.Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. We are really grateful to Grzegorz Zuzel for the radon emanation measurements. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROMETEO/2016/120; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & and the University of Texas at Arlington.Cebrian, S.; Perez, J.; Bandac, I.; Labarga, L.; Álvarez-Puerta, V.; Azevedo, CDR.; Benlloch-Rodriguez, JM.... (2017). Radiopurity assessment of the energy readout for the NEXT double beta decay experiment. Journal of Instrumentation. 12. https://doi.org/10.1088/1748-0221/12/08/T08003S12Avignone, F. T., Elliott, S. R., & Engel, J. (2008). Double beta decay, Majorana neutrinos, and neutrino mass. Reviews of Modern Physics, 80(2), 481-516. doi:10.1103/revmodphys.80.481Martín-Albo, J., Muñoz Vidal, J., Ferrario, P., Nebot-Guinot, M., Gómez-Cadenas, J. J., … Cárcel, S. (2016). Sensitivity of NEXT-100 to neutrinoless double beta decay. Journal of High Energy Physics, 2016(5). doi:10.1007/jhep05(2016)159Renner, J., Farbin, A., Vidal, J. M., Benlloch-Rodríguez, J. M., Botas, A., Ferrario, P., … Borges, F. I. G. (2017). Background rejection in NEXT using deep neural networks. Journal of Instrumentation, 12(01), T01004-T01004. doi:10.1088/1748-0221/12/01/t01004Dafni, T., Álvarez, V., Bandac, I., Bettini, A., Borges, F. I. G. M., Camargo, M., … Conde, C. A. N. (2016). Results of the material screening program of the NEXT experiment. Nuclear and Particle Physics Proceedings, 273-275, 2666-2668. doi:10.1016/j.nuclphysbps.2015.10.024Cebrián, S., Pérez, J., Bandac, I., Labarga, L., Álvarez, V., Barrado, A. I., … Cárcel, S. (2015). Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment. Journal of Instrumentation, 10(05), P05006-P05006. doi:10.1088/1748-0221/10/05/p05006Wang, X., Chen, X., Fu, C., Ji, X., Liu, X., Mao, Y., … Zhang, T. (2016). Material screening with HPGe counting station for PandaX experiment. Journal of Instrumentation, 11(12), T12002-T12002. doi:10.1088/1748-0221/11/12/t12002Barrow, P., Baudis, L., Cichon, D., Danisch, M., Franco, D., Kaether, F., … Wulf, J. (2017). Qualification tests of the R11410-21 photomultiplier tubes for the XENON1T detector. Journal of Instrumentation, 12(01), P01024-P01024. doi:10.1088/1748-0221/12/01/p01024Busto, J., Gonin, Y., Hubert, F., Hubert, P., & Vuilleumier, J.-M. (2002). Radioactivity measurements of a large number of adhesives. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 492(1-2), 35-42. doi:10.1016/s0168-9002(02)01280-9Nisi, S., Di Vacri, A., Di Vacri, M. L., Stramenga, A., & Laubenstein, M. (2009). Comparison of inductively coupled mass spectrometry and ultra low-level gamma-ray spectroscopy for ultra low background material selection. Applied Radiation and Isotopes, 67(5), 828-832. doi:10.1016/j.apradiso.2009.01.02

    Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

    Get PDF
    Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~ 1027 yr, requiring suppressing backgrounds to < 1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~ 5 when reconstructing electron-positron pairs in the 208Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~ 10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV e-e+ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency. [Figure not available: see fulltext.]. © 2021, The Author(s)

    Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives

    Get PDF
    [EN] We introduce a simulation framework for the transport of high and low energy electrons in xenon-based optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron-atom and electron-molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom-atom and atom-molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO2 and CF4 in a range of pressures from 0.1 to 10 bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology.DGD is supported by the Ramon y Cajal program (Spain) under contract number RYC-2015-18820. The authors want to acknowledge the RD51 collaboration for encouragement and support during the elaboration of this work, and in particular discussions with F. Resnati, A. Milov, V. Peskov, M. Suzuki and A. F. Borghesani. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROM-ETEO/2016/120; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A& and the University of Texas at Arlington.Azevedo, C.; Gonzalez-Diaz, D.; Biagi, SF.; Oliveira, CAB.; Henriques, CAO.; Escada, J.; Monrabal, F.... (2018). Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives. Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment. 877:157-172. https://doi.org/10.1016/j.nima.2017.08.049S15717287

    A Compact Dication Source for Ba2+^{2+} Tagging and Heavy Metal Ion Sensor Development

    Full text link
    We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba2+\mathrm{Ba^{2+}} ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb2+^{2+} and Cd2+^{2+} also demonstrated for this purpose
    corecore