2,836 research outputs found
Geo-environmental mapping using physiographic analysis: constraints on the evaluation of land instability and groundwater pollution hazards in the Metropolitan District of Campinas, Brazil
Geo-environmental terrain assessments and territorial zoning are useful tools for the formulation and implementation of environmental management instruments (including policy-making, planning, and enforcement of statutory regulations). They usually involve a set of procedures and techniques for delimitation, characterisation and classification of terrain units. However, terrain assessments and zoning exercises are often costly and time-consuming, particularly when encompassing large areas, which in many cases prevent local agencies in developing countries from properly benefiting from such assessments. In the present paper, a low-cost technique based on the analysis of texture of satellite imagery was used for delimitation of terrain units. The delimited units were further analysed in two test areas situated in Southeast Brazil to provide estimates of land instability and the vulnerability of groundwater to pollution hazards. The implementation incorporated procedures for inferring the influences and potential implications of tectonic fractures and other discontinuities on ground behaviour and local groundwater flow. Terrain attributes such as degree of fracturing, bedrock lithology and weathered materials were explored as indicators of ground properties. The paper also discusses constraints on- and limitations of- the approaches taken
Fish associated with aquatic macrophytes in the Chacororé-Sinhá Mariana Lake system and Mutum River, Pantanal of Mato Grosso, Brazil
Análise comparativa da função respiratória de indivÃduos hÃgidos em solo e na água
A mensuração da função respiratória oferece informações essenciais para caracterizar anormalidades pulmonares. A pressão hidrostática da água atua no tórax submerso de diversas formas, causando alterações no sistema respiratório. O objetivo deste estudo foi analisar comparativamente variáveis que avaliam a função respiratória - volume minuto (Vmin), volume corrente (Vc), capacidade vital (Cvital) e frequência respiratória (FR) - de voluntárias no solo e com o tórax submerso em piscina terapêutica aquecida. A função respiratória de 30 voluntárias saudáveis (20,9±2,1 anos; 1,64±0,07 m; 58,8±9,2 kg; Ãndice de massa corporal 21,78±2,63 kg/m²) foi avaliada por meio de ventilômetro em solo e aos 1 e 20 minutos de imersão, com água ao nÃvel dos ombros, em posição sentada. Após 20 minutos de imersão, foi registrado aumento estatisticamente significativo no Vmin (p=0,015) e Vc (p=0,027); e uma redução estatisticamente significativa (p=0,016) na Cvital 1 minuto após imersão, em relação aos valores obtidos em solo. O maior tempo de imersão alterou assim os valores obtidos em solo, com exceção da Cvital, que sofreu alteração significativa desde o primeiro minuto de imersão. Não foram encontradas diferenças significativas entre os valores obtidos após 1 e 20 minutos na água. O estudo permite concluir que a imersão do tórax em piscina aquecida provocou aumento no Vmin e Vc e diminuição na Cvital de voluntárias saudáveis.Measuring respiratory function provides essential information to assess pulmonary changes. Effects of water hydrostatic pressure on the submerged chest cause changes in the respiratory system. The purpose here was to compare respiratory function variables - minute volume (MV), tidal volume (TV), vital capacity (Vitalc), and respiratory rate (RR) - on the ground and with chest submerged in water. Respiratory function of 30 healthy female volunteers (mean age 20.93 ± 2.11; weight 58.8±9.2 kg; body mass index 21.78±2.63 kg/m²) was assessed by spirometry on the ground, and 1 and 20 minutes after immersion in warm water at shoulder level in the sitting position. As compared to ground levels, statistically significant increases were found in MV (p=0.015) and TV (p=0.027) 20 minutes after immersion, as well as a significant decrease (p=0.016) in Vitalc one minute after immersion. Longer time immersion has thus altered values obtained on ground, except for Vitalc, which showed significant reduction on the first minute after chest immersion. Comparison between variable values obtained 1 and 20 minutes in water showed no significant difference. It may thus be said that chest submersion in warm water caused an increase in MV and VT and a decrease in Vitalc of healthy subjects
Photographic assessment of nasal morphology following rapid maxillary expansion in children
Influence of different shades and LED irradiance on the degree of conversion of composite resins
Diversity, community structure and conservation status of an Atlantic Forest fragment in Rio de Janeiro State, Brazil
Care of adolescents sheltered in maternity hospitals from the perspective of health professionals
Chiral vanadyl salen catalyst immobilized on mesoporous silica as support for asymmetric oxidation of sulfides to sulfoxides
- …