231 research outputs found
Numerical Simulation of Turbulent Flow in a Pipe Oscillating Around Its Axis
The turbulent flow in a cilindrical pipe oscillating around its lungitudinal axis is studied via direct numerical solution of the Navier-Stokes equations, and compared to the reference turbulent flow in a fixed pipe and in a pipe with steady rotation. The maximum amount of drag reduction achievable with appropriate oscillations of the pipe wall is found to be of the order of 40%, hence comparable to that of similar flows in planar geometry. The transverse shear layer due to the oscillations induces substantial modifications to the turbulence statistics in the near-wall region, indicating a strong effect on the vortical structures. These modifications are illustrated, together with the implications for the drag-reducing mechanisms. A conceptual model of the interaction between the moving wall and a streamwise vortex is discussed
Volume control of the lower limb with graduated compression during different muscle pump activation conditions and the relation to limb circumference variation
Background: The literature supports the use of graduated compression stockings (GCS) for leg edema. Nevertheless, there is a paucity of data on the GCS effect on limb edema related to sitting, standing, and walking. Data of different limb shapes and their impact on GCS-exerted pressure are lacking. This investigation provides evidence-based information on the effect of GCS on edema reduction and the impact of limb circumference gradients on GCS pressure. Methods: Thirty healthy individuals (15 men and 15 women; mean age, 32 ± 5 years) were included. All the participants underwent lower limb volume (Kuhnke formula) measurement, before and after sitting for 30 minutes, wearing below-ankle noncompressive socks. The same assessment was repeated 7 days later, in the same participants, but with wearing of below-knee 16 to 20 mm Hg GCS. At 7-day intervals, 1 week with below-ankle noncompressive socks and 1 week with below-knee 16 to 20 mm Hg GCS, all the participants repeated the same protocol including standing and walking. Ten participants underwent bioimpedance assessment (Biody Xpert II; eBIODY, La Ciotat, France) before and after sitting, standing, and walking. In the same group, B and B1 interface pressure values were measured. Results: Data collection was completed in all 60 limbs. Sitting or walking without GCS led to no significant volume changes, whereas volume was decreased by the use of GCS (−4.8% [P <.00001] and −4.4% [P <.00001], respectively). Standing up without GCS led to an increase in volume (2.7%; P <.0001), whereas limb volume was decreased (4.6%; P <.0001) by use of GCS. Bioimpedance showed extracellular water reduction only while walking with GCS (from 40.55% ± 1.66% to 40.45% ± 1.71%; P <.017). Mean interface pressure was 19 ± 5 mm Hg (B) and 16 ± 5 mm Hg (B1). The interface pressure variation from B to B1 was not homogeneous among participants (mean percentage variation of −13% ± 25%, ranging from −54% to 16%). A negative linear trend between pressure variation and circumference percentage increase was found; the subanalysis excluding the two outliers showed a strong negative linear correlation (Pearson coefficient r = −0.96). Conclusions: GCS led to a significant limb volume reduction irrespective of limb position and muscle pump function. However, extracellular fluid is mobilized only during muscle contraction while walking with GCS. Interestingly, different lower limb circumference variations influence the interface pressure gradient, indicating the importance of proper fitting of both B and B1 during prescription. These data provide a foundation to future investigations dealing with GCS effect on fluid mobilization and with limb geometry impact on compression performance
Academic conflict of interest
PURPOSE: We set out to summarize the current challenges in academic conflict of interest.
METHODS: This is a narrative review by a multidisciplinary, multinational panel of academic officers including deans of medical/pharmacy schools.
RESULTS AND CONCLUSIONS: Disclosing conflict of interest has become the appropriate professional behavior since the 1990s in response to the necessity to fix moral and financial fences around medical activities. The nature of the conflict of interest is academic when either the conflict relates to academic duties and/or the nature of the interest is academic. People usually distinguish between real conflict of interest, when private interest overtly influences one\u27s professional obligations; potential conflict of interest, when there is no obvious direct link between a person interests and current duties without ruling out that expected changes in duties cause a situation of conflict; and apparent conflict of interest, when the risk does not really exist, but serious doubts remain. Areas at risk of academic conflict of interest include peer review process for grant evaluation or journals, scientific communications such as elaborating and disseminating clinical guidelines, lecturing at meeting, advising decision-makers, teaching activities, and mentoring. The management of academic conflict of interest should consider actions in four domains, i.e., education, prevention, measures for enforcement and solving, and communication. Academic conflicts of interest are as frequent as financial conflicts but more difficult to identify and assess, and much less addressed in the literature. Generating more evidence from high-quality research is mandated to improve the management of academic and more generally non-financial conflicts of interest
Effectiveness of complete conservative treatment for adolescent idiopathic scoliosis (bracing and exercises) based on SOSORT management criteria: results according to the SRS criteria for bracing studies - SOSORT Award 2009 Winner
<p>Abstract</p> <p>Background</p> <p>The SRS criteria give the methodological reference framework for the presentation of bracing results, while the SOSORT criteria give the clinical reference framework for an appropriate bracing treatment. The two have not been combined in a study until now. Our aim was to verify the efficacy of a complete, conservative treatment of Adolescent Idiopathic Scoliosis (AIS)according to the best methodological and management criteria defined in the literature.</p> <p>Methods</p> <p>Study Design. Retrospective study. Population. We included all AIS patients respecting the SRS inclusion criteria (age 10 years or older; Risser test 0-2; Cobb degrees 25-40°; no prior treatment; less than one year post-menarchal) who had reached the end of treatment since our institute database start in 2003. Thus we had 44 females and four males, with an age of 12.8 ± 1.6 at the commencement of the study. Methods. According to individual needs, two patients have been treated with Risser casts followed by Lyon brace, 40 with Lyon or SPoRT braces (14 for 23 hours per day, 23 for 21 h/d, and seven for 18 h/d at start), and two with exercises only (1 male, 1 female): these were excluded from further analysis. Outcome criteria. SRS (unchanged; worsened 6° or more; over 45° at the end of treatment; surgically treated; two years' follow-up); clinical (ATR, Aesthetic Index, plumbline distances); radiographic (Cobb degrees); and ISICO (optimal; minimal). Statistics. Paired ANOVA and t-test, Tukey-Kramer and chi-square test.</p> <p>Results</p> <p>Median reported compliance during the 4.2 ± 1.4 treatment years was 90% (range 5-106%). No patient progressed beyond 45°, nor was any patient fused, and this remained true at the two-year follow-up for the 85% that reached it. Only two patients (4%) worsened, both with single thoracic curve, 25-30° Cobb and Risser 0 at the start. We found statistically significant reductions of the scoliosis curvatures (-7.1°): thoracic (-7.3°), thoracolumbar (-8.4°) and lumbar (-7.8°), but not double major. Statistically significant improvements have also been found for aesthetics and ATR.</p> <p>Conclusion</p> <p>Respecting also SOSORT management criteria and thus increasing compliance, the results of conservative treatment were much better than what had previously been reported in the literature using SRS criteria only.</p
Forces exerted during exercises by patients with adolescent idiopathic scoliosis wearing fiberglass braces
OBJECTIVE: To quantify and compare the forces exerted by scoliosis patients in fiberglass braces during exercises usually prescribed in departments where casts are made. The exercises are intended to increase corrective forces, activate muscles, stimulate ventilation and help the patient psychologically. SETTING: Outpatient care. PATIENTS: 17 consecutive adolescent patients wearing fiberglass brace for idiopathic scoliosis. INTERVENTIONS: Exercises (kyphotization, rotation, "escape from the pad") in different positions (sitting, supine, on all fours). MAIN OUTCOME MEASURE: Pressure detected by the F-Socket System between the rib hump and the pad of the brace. RESULTS: In static and dynamic conditions, the position adopted did not alter the total pressure exerted by the brace, although the part of the sensor stimulated did vary. Kyphotization and rotation exercises produced a significant increase of pressure (+ 58.9% and +29.8%, respectively); however, the "escape from the pad" exercise, despite its name, did not produce any significant variation of pressure. CONCLUSION: Exercises in the brace allow adjunctive forces to be applied on soft tissues and through them, presumably on the spine. Different exercises can be chosen to obtain different actions. Physical exercises and sporting activities are useful in mechanical terms, although other important actions should not be overlooked
- …