739 research outputs found

    Comparison of Image Registration Based Measures of Regional Lung Ventilation from Dynamic Spiral CT with Xe-CT

    Full text link
    Purpose: Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this article, we propose a new regional measure of lung mechanics --- the specific air volume change by corrected Jacobian. Methods: 4DCT and Xe-CT data sets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration-based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). Results: After registration, the mean registration error is on the order of 1 mm. For cubical ROIs in cubes with size 20 mm ×\times 20 mm ×\times 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r2=0.75r^2=0.75 and r2=0.82r^2=0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm ×\times 8 mm ×\times 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r2=0.88r^2=0.88, r2=0.92r^2=0.92 and r2=0.87r^2=0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. Conclusion: Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied

    Investigation of Surface Magnetic Noise by Shallow Spins in Diamond

    Get PDF
    We present measurements of spin relaxation times (T1, T1ρ, T2) on very shallow (≲5  nm) nitrogen-vacancy centers in high-purity diamond single crystals. We find a reduction of spin relaxation times up to 30 times compared to bulk values, indicating the presence of ubiquitous magnetic impurities associated with the surface. Our measurements yield a density of 0.01–0.1μB/nm2 and a characteristic correlation time of 0.28(3) ns of surface states, with little variation between samples and chemical surface terminations. A low temperature measurement further confirms that fluctuations are thermally activated. The data support the atomistic picture where impurities are associated with the top carbon layers, and not with terminating surface atoms or adsorbate molecules. The low spin density implies that the presence of A single surface impurity is sufficient to cause spin relaxation of a shallow nitrogen-vacancy center

    Self-similar shear-thickening behavior in CTAB/NaSal surfactant solutions

    Full text link
    The effect of salt concentration Cs on the critical shear rate required for the onset of shear thickening and apparent relaxation time of the shear-thickened phase, has been investigated systematically for dilute CTAB/NaSal solutions. Experimental data suggest a self-similar behavior of the critical shear rate and relaxation time as functions of Cs. Specifically, the former ~ Cs^(-6) whereas the latter ~ Cs^(6) such that an effective Weissenberg number for the onset of the shear thickened phase is only weakly dependent on Cs. A procedure has been developed to collapse the apparent shear viscosity versus shear rate data obtained for various values of Cs into a single master curve. The effect of Cs on the elastic modulus and mesh size of the shear-induced gel phase for different surfactant concentrations is discussed. Experiments performed using different flow cells (Couette and cone-and-plate) show that the critical shear rate, relaxation time and the maximum viscosity attained are geometry-independent. The elastic modulus of the gel phase inferred indirectly by employing simplified hydrodynamic instability analysis of a sheared gel-fluid interface is in qualitative agreement with that predicted for an entangled phase of living polymers. A qualitative mechanism that combines the effect of Cs on average micelle length and Debye parameter with shear-induced configurational changes of rod-like micelles is proposed to rationalize the self-similarity of SIS formation.Comment: 27 pages, 17 figure

    A direct numerical simulation method for complex modulus of particle dispersions

    Full text link
    We report an extension of the smoothed profile method (SPM)[Y. Nakayama, K. Kim, and R. Yamamoto, Eur. Phys. J. E {\bf 26}, 361(2008)], a direct numerical simulation method for calculating the complex modulus of the dispersion of particles, in which we introduce a temporally oscillatory external force into the system. The validity of the method was examined by evaluating the storage G(ω)G'(\omega) and loss G"(ω)G"(\omega) moduli of a system composed of identical spherical particles dispersed in an incompressible Newtonian host fluid at volume fractions of Φ=0\Phi=0, 0.41, and 0.51. The moduli were evaluated at several frequencies of shear flow; the shear flow used here has a zigzag profile, as is consistent with the usual periodic boundary conditions

    On measuring colloidal volume fractions

    Full text link
    Hard-sphere colloids are popular as models for testing fundamental theories in condensed matter and statistical physics, from crystal nucleation to the glass transition. A single parameter, the volume fraction (phi), characterizes an ideal, monodisperse hard-sphere suspension. In comparing experiments with theories and simulation, researchers to date have paid little attention to likely uncertainties in experimentally-quoted phi values. We critically review the experimental measurement of phi in hard-sphere colloids, and show that while statistical uncertainties in comparing relative values of phi can be as low as 0.0001, systematic errors of 3-6% are probably unavoidable. The consequences of this are illustrated by way of a case study comparing literature data sets on hard-sphere viscosity and diffusion.Comment: 11 page

    Investigation of Surface Magnetic Noise by Shallow Spins in Diamond

    Get PDF
    We present measurements of spin relaxation times (T1, T1ρ, T2) on very shallow (≲5  nm) nitrogen-vacancy centers in high-purity diamond single crystals. We find a reduction of spin relaxation times up to 30 times compared to bulk values, indicating the presence of ubiquitous magnetic impurities associated with the surface. Our measurements yield a density of 0.01–0.1μB/nm2 and a characteristic correlation time of 0.28(3) ns of surface states, with little variation between samples and chemical surface terminations. A low temperature measurement further confirms that fluctuations are thermally activated. The data support the atomistic picture where impurities are associated with the top carbon layers, and not with terminating surface atoms or adsorbate molecules. The low spin density implies that the presence of A single surface impurity is sufficient to cause spin relaxation of a shallow nitrogen-vacancy center
    corecore