12 research outputs found

    Segmentation of Pulmonary Vascular Trees from Thoracic 3D CT Images

    Get PDF
    This paper describes an algorithm for extracting pulmonary vascular trees (arteries plus veins) from three-dimensional (3D) thoracic computed tomographic (CT) images. The algorithm integrates tube enhancement filter and traversal approaches which are based on eigenvalues and eigenvectors of a Hessian matrix to extract thin peripheral segments as well as thick vessels close to the lung hilum. The resultant algorithm was applied to a simulation data set and 44 scans from 22 human subjects imaged via multidetector-row CT (MDCT) during breath holds at 85% and 20% of their vital capacity. A quantitative validation was performed with more than 1000 manually identified points selected from inside the vessel segments to assess true positives (TPs) and 1000 points randomly placed outside of the vessels to evaluate false positives (FPs) in each case. On average, for both the high and low volume lung images, 99% of the points was properly marked as vessel and 1% of the points were assessed as FPs. Our hybrid segmentation algorithm provides a highly reliable method of segmenting the combined pulmonary venous and arterial trees which in turn will serve as a critical starting point for further quantitative analysis tasks and aid in our overall goal of establishing a normative atlas of the human lung

    Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies

    No full text
    Xenon-enhanced computed tomography (Xe-CT) has been used to measure regional ventilation by determining the wash-in (WI) and wash-out (WO) rates of stable Xe. We tested the common assumption that WI and WO rates are equal by measuring WO–WI in different anatomic lung regions of six anesthetized, supine sheep scanned using multi-detector-row computed tomography (MDCT). We further investigated the effect of tidal volume, image gating (end-expiratory EE versus end-inspiratory EI), local perfusion, and inspired Xe concentration on this phenomenon. Results: WO time constant was greater than WI in all lung regions, with the greatest differences observed in dependent base regions. WO–WI time constant difference was greater during EE imaging, smaller tidal volumes, and with higher Xe concentrations. Regional perfusion did not correlate with WI–WO. We conclude that Xe-WI rate can be significantly different from the WO rate, and the data suggest that this effect may be due to a combination of anatomic and fluid mechanical factors such as Rayleigh–Taylor instabilities set up at interfaces between two gases of different densities
    corecore