233 research outputs found
Theoretical analysis of Wolter/LSM X-ray telescope systems
A ray tracing analysis has been performed for the spectral slicing zoom X-ray telescope for configurations in which a convex layered synthetic microstructure (LSM) optic is placed in front of the prime focus or a concave LSM optic is placed behind the prime focus. The analysis has considered the geometrical shape of the LSM optic to be either a hyperboloid, sphere, ellipsoid or constant optical path aspheric element for two configurations of the glancing incidence X-ray telescope: the ATM Experimental S-056 Wolter I system and the Stanford/MSFC Wolter-Schwarzchild nested system. For the different systems the RMS blur circle radii, the point spread function (PSF), the full width half maximum (FWHM) of the PSF have been evaluated as a function of field angle and magnification of the secondary to determine resolution of the system. The effects of decentration and tilt of the selected LSM element on the performance of the system have been studied to determine mounting and alignment tolerances
Theoretical design and analysis of the layered synthetic microstructure optic for the dual path X-ray telescope
A ray tracing analysis was performed for several configurations for the inner channel of the dual path X-ray telescope, which is proposed to use the second mirror of the Stanford/MSFC Wolter-Schwarzchild telescope and a normal incident layered synthetic microstructure (LSM) mirror to form a secondary image near the front of the telescope. The LSM mirror shapes considered were spherical, ellipsoid, hyperboloid, and constant optical path length (OPL) aspheric. Only the constant OPL case gave good axial resolution. All cases had poor off axis resolution as judged by the RMS blur circle radius
Theoretical analysis of segmented Wolter/LSM X-ray telescope systems
The Segmented Wolter I/LSM X-ray Telescope, which consists of a Wolter I Telescope with a tilted, off-axis convex spherical Layered Synthetic Microstructure (LSM) optics placed near the primary focus to accommodate multiple off-axis detectors, has been analyzed. The Skylab ATM Experiment S056 Wolter I telescope and the Stanford/MSFC nested Wolter-Schwarzschild x-ray telescope have been considered as the primary optics. A ray trace analysis has been performed to calculate the RMS blur circle radius, point spread function (PSF), the meridional and sagittal line functions (LST), and the full width half maximum (PWHM) of the PSF to study the spatial resolution of the system. The effects on resolution of defocussing the image plane, tilting and decentrating of the multilayer (LSM) optics have also been investigated to give the mounting and alignment tolerances of the LSM optic. Comparison has been made between the performance of the segmented Wolter/LSM optical system and that of the Spectral Slicing X-ray Telescope (SSXRT) systems
Analysis of NOAA-MSFC GOES X-ray telescope
The general telescope system was assumed to be a paraboloid-hyperboloid in a Wolter Type 1 configuration. The equations which specify the telescope parameters and the resolution as a function of the collecting area are discussed as well as the spot size and point response function for off-axis rays. The measured resolution of the Goddard ATM X-ray telescope (S-056) is compared to the rms blur circle radius and the full width half maximum of the line spread function. An empirical scaling formula, Eq. 26, which transforms the rms blur circle radius into a more accurate measure of resolution, is introduced. The geometrical imaging properties of the proposed NOAA-MSFC GOES X-ray telescope are considered. Conclusions and alternate mirror designs are included
Advanced water window x-ray microscope design and analysis
The project was focused on the design and analysis of an advanced water window soft-x-ray microscope. The activities were accomplished by completing three tasks contained in the statement of work of this contract. The new results confirm that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use aspherical mirror surfaces and to use graded multilayer coatings on the secondary (to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater). The results are included in a manuscript which is enclosed in the Appendix
Sand River Headwaters Green Infrastructure Project, City of Aiken, South Carolina: A Collaborative Team Approach to Implementing Green Infrastructure Practices
2010 S.C. water Resources Conference - Science and Policy Challenges for a Sustainable Futur
Synthesis and Quantitative Structure–Activity Relationship of Imidazotetrazine Prodrugs with Activity Independent of O6-Methylguanine-DNA-methyltransferase, DNA Mismatch Repair and p53.
The antitumor prodrug Temozolomide is compromised by its dependence for activity on DNA mismatch repair (MMR) and the repair of the chemosensitive DNA lesion, O6-methylguanine (O6-MeG), by O6-methylguanine-DNA-methyltransferase (EC 2.1.1.63, MGMT). Tumor response is also dependent on wild-type p53. Novel 3-(2-anilinoethyl)-substituted imidazotetrazines are reported that have activity independent of MGMT, MMR and p53. This is achieved through a switch of mechanism so that bioactivity derives from imidazotetrazine-generated arylaziridinium ions that principally modify guanine-N7 sites on DNA. Mono- and bi-functional analogs are reported and a quantitative structure-activity relationship (QSAR) study identified the p-tolyl-substituted bi-functional congener as optimized for potency, MGMT-independence and MMR-independence. NCI60 data show the tumor cell response is distinct from other imidazotetrazines and DNA-guanine-N7 active agents such as nitrogen mustards and cisplatin. The new imidazotetrazine compounds are promising agents for further development and their improved in vitro activity validates the principles on which they were designed
Urinary Concentrations of Dialkylphosphate Metabolites of Organophosphorus Pesticides: National Health and Nutrition Examination Survey 1999–2004
Organophosphorus (OP) insecticides were among the first pesticides that EPA reevaluated as part of the Food Quality Protection Act of 1996. Our goal was to assess exposure to OP insecticides in the U.S. general population over a six-year period. We analyzed 7,456 urine samples collected as part of three two-year cycles of the National Health and Nutrition Examination Survey (NHANES) from 1999–2004. We measured six dialkylphosphate metabolites of OP pesticides to assess OP pesticide exposure. In NHANES 2003–2004, dimethylthiophosphate was detected most frequently with median and 95th percentile concentrations of 2.03 and 35.3 μg/L, respectively. Adolescents were two to three times more likely to have diethylphosphate concentrations above the 95th percentile estimate of 15.5 μg/L than adults and senior adults. Conversely, for dimethyldithiophosphate, senior adults were 3.8 times and 1.8 times more likely to be above the 95th percentile than adults and adolescents, respectively, while adults were 2.1 times more likely to be above the 95th percentile than the adolescents. Our data indicate that the most vulnerable segments of our population—children and older adults—have higher exposures to OP pesticides than other population segments. However, according to DAP urinary metabolite data, exposures to OP pesticides have declined during the last six years at both the median and 95th percentile levels
A closed loop brain-machine interface for epilepsy control using dorsal column electrical stimulation
Although electrical neurostimulation has been proposed as an alternative treatment for drug-resistant cases of epilepsy, current procedures such as deep brain stimulation, vagus, and trigeminal nerve stimulation are effective only in a fraction of the patients. Here we demonstrate a closed loop brain-machine interface that delivers electrical stimulation to the dorsal column (DCS) of the spinal cord to suppress epileptic seizures. Rats were implanted with cortical recording microelectrodes and spinal cord stimulating electrodes, and then injected with pentylenetetrazole to induce seizures. Seizures were detected in real time from cortical local field potentials, after which DCS was applied. This method decreased seizure episode frequency by 44% and seizure duration by 38%. We argue that the therapeutic effect of DCS is related to modulation of cortical theta waves, and propose that this closed-loop interface has the potential to become an effective and semi-invasive treatment for refractory epilepsy and other neurological disorders.We are grateful for the assistance from Jim Meloy for the design and production of the multielectrode arrays as well as setup development and maintenance, Laura Oliveira, Terry Jones, and Susan Halkiotis for administrative assistance and preparation of the manuscript. This work was funded by a grant from The Hartwell Foundation.info:eu-repo/semantics/publishedVersio
- …