284 research outputs found

    Differential patterns of activity and functional connectivity in emotion processing neural circuitry to angry and happy faces in adolescents with and without suicide attempt

    Get PDF
    Background - Neural substrates of emotion dysregulation in adolescent suicide attempters remain unexamined. Method - We used functional magnetic resonance imaging to measure neural activity to neutral, mild or intense (i.e. 0%, 50% or 100% intensity) emotion face morphs in two separate emotion-processing runs (angry and happy) in three adolescent groups: (1) history of suicide attempt and depression (ATT, n = 14); (2) history of depression alone (NAT, n = 15); and (3) healthy controls (HC, n = 15). Post-hoc analyses were conducted on interactions from 3 group × 3 condition (intensities) whole-brain analyses (p < 0.05, corrected) for each emotion run. Results - To 50% intensity angry faces, ATT showed significantly greater activity than NAT in anterior cingulate gyral–dorsolateral prefrontal cortical attentional control circuitry, primary sensory and temporal cortices; and significantly greater activity than HC in the primary sensory cortex, while NAT had significantly lower activity than HC in the anterior cingulate gyrus and ventromedial prefrontal cortex. To neutral faces during the angry emotion-processing run, ATT had significantly lower activity than NAT in the fusiform gyrus. ATT also showed significantly lower activity than HC to 100% intensity happy faces in the primary sensory cortex, and to neutral faces in the happy run in the anterior cingulate and left medial frontal gyri (all p < 0.006,corrected). Psychophysiological interaction analyses revealed significantly reduced anterior cingulate gyral–insula functional connectivity to 50% intensity angry faces in ATT v. NAT or HC. Conclusions - Elevated activity in attention control circuitry, and reduced anterior cingulate gyral–insula functional connectivity, to 50% intensity angry faces in ATT than other groups suggest that ATT may show inefficient recruitment of attentional control neural circuitry when regulating attention to mild intensity angry faces, which may represent a potential biological marker for suicide risk

    Improved procedural workflow for catheter ablation of paroxysmal AF with high-density mapping system and advanced technology: Rationale and study design of a multicenter international study

    Full text link
    The antral region of pulmonary veins (PV)s seems to play a key role in a strategy aimed at preventing atrial fibrillation (AF) recurrence. Particularly, low-voltage activity in tissue such as the PV antra and residual potential within the antral scar likely represent vulnerabilities in antral lesion sets, and ablation of these targets seems to improve freedom from AF. The aim of this study is to validate a structured application of an approach that includes the complete abolition of any antral potential achieving electrical quiescence in antral regions.The improveD procEdural workfLow for cathETEr ablation of paroxysmal AF with high density mapping system and advanced technology (DELETE AF) study is a prospective, single-arm, international post-market cohort study designed to demonstrate a low rate of clinical atrial arrhythmias recurrence with an improved procedural workflow for catheter ablation of paroxysmal AF, using the most advanced point-by-point RF ablation technology in a multicenter setting. About 300 consecutive patients with standard indications for AF ablation will be enrolled in this study. Post-ablation, all patients will be monitored with ambulatory event monitoring, starting within 30 days post-ablation to proactively detect and manage any recurrences within the 90-day blanking period, as well as Holter monitoring at 3, 6, 9, and 12 months post-ablation. Healthcare resource utilization, clinical data, complications, patients' medical complaints related to the ablation procedure and patient's reported outcome measures will be prospectively traced and evaluated.The DELETE AF trial will provide additional knowledge on long-term outcome following a structured ablation workflow, with high density mapping, advanced algorithms and local impedance technology, in an international multicentric fashion. DELETE AF is registered at ClinicalTrials.gov (NCT05005143).© 2022 The Authors. Clinical Cardiology published by Wiley Periodicals LLC

    Transvenous Lead Extraction in Patients with Cardiac Implantable Device: The Impact of Systemic and Local Infection on Clinical Outcomes. An ESC‐EHRA ELECTRa (European Lead Extraction Controlled) Registry Substudy

    Get PDF
    Background: Infections of cardiac implantable devices (CIEDI) have poor outcomes despite improvement in lead extraction (TLE) procedures. Methods: To explore the influence of CIEDI on the outcomes of TLE and the differences between patients with systemic (Sy) vs. local (Lo) CIEDI, we performed a sub‐analysis of the EORP ELECTRa (European Lead Extraction ConTRolled) Registry. Results: Among 3555 patients enrolled by 73 centers in 19 Countries, the indication for TLE was CIEDI in 1850: 1170 with Lo‐CIEDI and 680 with Sy‐CIEDI. Patients with CIEDI had a worse in‐hospital prognosis in terms of major complications (3.57% vs. 1.71%; p = 0.0007) and mortality (2.27% vs. 0.49%; p &lt; 0.0001). Sy‐CIEDI was an independent predictor of in‐hospital death (H.R. 2.14; 95%CI 1.06–4.33. p = 0.0345). Patients with Sy‐CIEDI more frequently had an initial CIED implant and a higher prevalence of comorbidities, while subjects with Lo‐CIEDI had a higher prevalence of previous CIED procedures. Time from signs of CIEDI and TLE was longer for Lo‐CIEDI despite a shorter pre‐TLE antibiotic treatment. Conclusions: Patients with CIEDI have a worse in‐hospital prognosis after TLE, especially for patients with Sy‐CIEDI. These results raise the suspicion that in a relevant group of patients CIEDI can be systemic from the beginning without progression from Lo‐CIEDI. Future research is needed to characterize this subgroup of patients

    Multicenter Study of High-Dose Daptomycin for Treatment of Enterococcal Infections

    Get PDF
    Enterococci are among the leading pathogens isolated in hospital-acquired infections. Current antimicrobial options for vancomycin-resistant enterococci (VRE) are limited. Prior data suggests that daptomycin \u3e 6mg/kg/day may be used to treat enterococcal infections. We retrospectively evaluated the effectiveness and safety of high-dose daptomycin (HD-daptomycin) therapy (\u3e 6 mg/kg) in a multicenter cohort of adult patients with enterococcal infections to describe the characteristics and outcomes. Two-hundred and forty-five patients were evaluated. Enterococcus faecium was identified in 175 (71%), followed by 49 (20%) Enterococcus faecalis and 21 (9%) Enterococcus spp., overall 204 (83%) were VRE. Enterococcal infections included bacteremia (173, 71%), intra-abdominal (35, 14%) and bone/joint (25, 10%). The median dose and duration of HD-daptomycin was 8.2 mg/kg/day (IQR 7.7-9.7) and 10 days (IQR 6-15), respectively. Overall clinical success rate was 89% (193/218) and microbiological eradication was observed in 93% (177/191) of patients. The median time to clearance of blood cultures on HD-daptomycin was 3 days (IQR 2-5). Thirty-day all cause mortality rate was 27% and 5 (2%) patients developed daptomycin nonsusceptible enterococcal strains while on HD-daptomycin. Seven patients (3%) had creatine phosphokinase (CPK) elevation, yet no HD-daptomycin regimen was discontinued due to an elevated CPK and all patients were asymptomatic. Overall, there was a high frequency of clinical success and microbiological eradication in patients treated with HD-daptomycin for enterococcal infections, even in patients with complicated and difficult to treat infections. No adverse event-related discontinuation of HD-daptomycin was noted. HD-daptomycin may be an option for the treatment of enterococcal infections

    Insertion Magnets

    Full text link
    Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.Comment: 19 pages, Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Repor

    Safety and Efficacy of a Single Procedure of Extraction and Reimplantation of Infected Cardiovascular Implantable Electronic Device (CIED) in Comparison with Deferral Timing: An Observational Retrospective Multicentric Study

    Get PDF
    (1) Background: Infections are among the most frequent and life-threatening complications of cardiovascular implantable electronic device (CIED) implantation. The aim of this study is to compare the outcome and safety of a single-procedure device extraction and contralateral implantation versus the standard-of-care (SoC) two-stage replacement for infected CIEDs. (2) Methods: We retrospectively included 66 patients with CIED infections who were treated at two Italian hospitals. Of the 66 patients enrolled in the study, 27 underwent a single procedure, whereas 39 received SoC treatment. All patients were followed up for 12 months after the procedure. (3) Results: Considering those lost to follow-up, there were no differences in the mortality rates between the two cohorts, with survival rates of 81.5% in the single-procedure group and 84.6% in the SoC group (p = 0.075). (4) Conclusions: Single-procedure reimplantation associated with an active antibiofilm therapy may be a feasible and effective therapeutic option in CIED-dependent and frail patients. Further studies are warranted to define the best treatment regimen and strategies to select patients suitable for the single-procedure reimplantation

    Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads

    Get PDF
    Abstract: The aim of the present study was to describe a 10 years single-centre experience in pacing and defibrillating leads removal using an effective and safe modified mechanical dilatation technique. We developed a single mechanical dilating sheath extraction technique with multiple venous entry site approaches. We performed a venous entry site approach (VEA) in cases of exposed leads and an alternative transvenous femoral approach (TFA) combined with an internal transjugular approach (ITA) in the presence of very tight binding sites causing failure of VEA extraction or in cases of free-floating leads. We attempted to remove 2062 leads [1825 pacing and 237 implantable cardiac defibrillating (ICD) leads; 1989 exposed at the venous entry site and 73 free-floating] in 1193 consecutive patients. The VEA was effective in 1799 leads, the TFA in 28, and the ITA in 205; in the overall population, we completely removed 2032 leads (98.4%), partially removed 18 (0.9%), and failed to remove 12 leads (0.6%). Major complications were observed in eight patients (0.7%), causing three deaths (0.3%). Mechanical single sheath extraction technique with multiple venous entry site approaches is effective, safe, and with a good cost effective profile for pacing and ICD leads removal
    corecore