28 research outputs found

    Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons

    Get PDF
    Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury

    A transverse isotropic viscoelastic constitutive model for aortic valve tissue

    Get PDF
    A new anisotropic viscoelastic model is developed for application to the aortic valve (AV). The directional dependency in the mechanical properties of the valve, arising from the predominantly circumferential alignment of collagen fibres, is accounted for in the form of transverse isotropy. The rate dependency of the valve's mechanical behaviour is considered to stem from the viscous (η) dissipative effects of the AV matrix, and is incorporated as an explicit function of the deformation rate (λ˙). Model (material) parameters were determined from uniaxial tensile deformation tests of porcine AV specimens at various deformation rates, by fitting the model to each experimental dataset. It is shown that the model provides an excellent fit to the experimental data across all different rates and satisfies the condition of strict local convexity. Based on the fitting results, a nonlinear relationship between η and λ˙ is established, highlighting a ‘shear-thinning’ behaviour for the AV with increase in the deformation rate. Using the model and these outcomes, the stress–deformation curves of the AV tissue under physiological deformation rates in both the circumferential and radial directions are predicted and presented. To verify the predictive capabilities of the model, the stress–deformation curves of AV specimens at an intermediate deformation rate were estimated and validated against the experimental data at that rate, showing an excellent agreement. While the model is primarily developed for application to the AV, it may be applied without the loss of generality to other collagenous soft tissues possessing a similar structure, with a single preferred direction of embedded collagen fibres

    An in vitro investigation into the effects of 10Hz cyclic loading on tenocyte metabolism

    Get PDF
    Tendinopathy is a prevalent, highly debilitating condition, with poorly defined aetiology. A wide range of clinical treatments have been proposed, with systematic reviews largely supporting shock wave therapy or eccentric exercise. Characterising these treatments has demonstrated both generate perturbations within tendon at a frequency of approximately 812Hz. Consequently, it is hypothesised that loading in this frequency range initiates increased anabolic tenocyte behaviour, promoting tendon repair. The primary aim of this study is to investigate the effects of 10Hz perturbations on tenocyte metabolism, comparing gene expression in response to a 10Hz and 1Hz loading profile. Tenocytes from healthy and tendinopathic human tendons were seeded into 3D collagen gels and subjected to 15 mins cyclic strain at 10Hz or 1Hz. Tenocytes from healthy tendon showed increased expression of all analysed genes in response to loading, with significantly increased expression of inflammatory and degradative genes with 10Hz, relative to 1Hz loading. By contrast, whilst the response of tenocytes from tendinopathy tendon also increased with 10Hz loading, the overall response profile was more varied and less intense, possibly indicative of an altered healing response. Through inhibition of the pathway, IL1 was shown to be involved in the degradative and catabolic response of cells to high frequency loading, abrogating the loading response. This study has demonstrated for the first time that loading at a frequency of 10Hz may enhance the metabolic response of tenocytes by initiating an immediate degradatory and inflammatory cell response through the IL1 pathway, perhaps as an initial stage of tendon healing

    Specialization of tendon mechanical properties results from interfascicular differences

    Get PDF
    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage

    Incidence and prevalence of patellofemoral pain: a systematic review and meta-analysis

    Get PDF
    Background: Patellofemoral pain is considered one of the most common forms of knee pain, affecting adults, adolescents, and physically active populations. Inconsistencies in reported incidence and prevalence exist and in relation to the allocation of healthcare and research funding, there is a clear need to accurately understand the epidemiology of patellofemoral pain. Methods: An electronic database search was conducted, as well as grey literature databases, from inception to June 2017. Two authors independently selected studies, extracted data and appraised methodological quality. If heterogeneous, data were analysed descriptively. Where studies were homogeneous, data were pooled through a meta-analysis. Results: 23 studies were included. Annual prevalence for patellofemoral pain in the general population was reported as 22.7%, and adolescents as 28.9%. Incidence rates in military recruits ranged from 9.7 – 571.4/1,000 person-years, amateur runners in the general population at 1080.5/1,000 person-years and adolescents amateur athletes 5.1% - 14.9% over 1 season. One study reported point prevalence within military populations as 13.5%. The pooled estimate for point prevalence in adolescents was 7.2% (95% Confidence Interval: 6.3% - 8.3%), and in female only adolescent athletes was 22.7% (95% Confidence Interval 17.4% - 28.0%). Conclusion: This review demonstrates high incidence and prevalence levels for patellofemoral pain. Within the context of this, and poor long term prognosis and high disability levels, PFP should be an urgent research priority

    Eccentric and concentric exercise of the triceps surae: an in vivo study of dynamic muscle and tendon biomechanical parameters

    No full text
    Triceps surae eccentric exercise is more effective than concentric exercise for treating Achilles tendinopathy, however the mechanisms underpinning these effects are unclear. This study compared the biomechanical characteristics of eccentric and concentric exercises to identify differences in the tendon load response. Eleven healthy volunteers performed eccentric and concentric exercises on a force plate, with ultrasonography, motion tracking, and EMG applied to measure Achilles tendon force, lower limb movement, and leg muscle activation. Tendon length was ultrasonographically tracked and quantified using a novel algorithm. The Fourier transform of the ground reaction force was also calculated to investigate for tremor, or perturbations. Tendon stiffness and extension did not vary between exercise types (P = .43). However, tendon perturbations were significantly higher during eccentric than concentric exercises (25%-40% higher, P = .02). Furthermore, perturbations during eccentric exercises were found to be negatively correlated with the tendon stiffness (R2 = .59). The particular efficacy of eccentric exercise does not appear to result from variation in tendon stiffness or extension within a given session. However, varied perturbation magnitude may have a role in mediating the observed clinical effects. This property is subject-specific, with the source and clinical time-course of such perturbations requiring further research

    Tendon functional extracellular matrix.

    Get PDF
    This article is one of a series, summarizing views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the "Functional Extracellular Matrix" stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment, and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely varying extrinsic and intrinsic factors such as age, nutrition, exercise levels, and biomechanics. Consequently, tendon adapts dynamically during development, aging, and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair
    corecore