349 research outputs found

    Relaxation of a Rubbed Polystyrene Surface

    Get PDF
    The relaxation dynamics of a rubbed polystyrene (PS) surface have been characterized using infrared-visible sum frequency generation spectroscopy (SFG). The SFG results were compared with previous relaxation of retardation measurements, and the results show that the rubbed PS surface has the same T(g) as the bulk where T(g) is defined as tau(T(g))=5 s, however, the surface has a lower activation energy (DeltaE) and a larger stretching exponent (beta(KWW)) than bulk PS. This indicates that the surface region relaxes more quickly than the bulk. The thickness of this region of lower DeltaE and larger beta(KWW) is estimated to be roughly 12 nm

    A Device for Surface Study of Confined Micron Thin Films in a Total Internal Reflection Geometry

    Get PDF
    A device to probe the molecular structure of materials next to a solid interface in a thin film geometry has been developed. The device can produce controlled thicknesses as small as 1 mum with parallelity better than 0.003degrees. We have shown that the thickness and the parallelity of the film produced between two optical surfaces can be quantified using white light and monochromatic light interferometry, respectively. In addition, this apparatus allows the study of these films in a static state or under shear using spectroscopic techniques involving transmission or reflection measurements. (C) 2002 American Institute of Physics

    Molecular Structure of Polystyrene at Air/Polymer and Solid/Polymer Interfaces

    Get PDF
    IR-visible sum-frequency generation(SFG) spectroscopy has been used in a total internal reflection geometry to study the molecular structure of polystyrene (PS) at PS/sapphire and PS/air interfaces, simultaneously. The symmetric vibrational modes of the phenyl rings dominate the SFG spectra at the PS/air interface as compared to the antisymmetric vibrational modes at the PS/sapphire interface. This indicates approximately parallel orientation of the phenyl rings at the PS/air interface while nearly perpendicular orientation at the PS/sapphire interface, with respect to the surface normal

    Are degenerative findings detected on traction MR arthrography of the hip associated with failure of arthroscopic femoroacetabular impingement surgery?

    Get PDF
    OBJECTIVES To identify preoperative degenerative features on traction MR arthrography associated with failure after arthroscopic femoroacetabular impingement (FAI) surgery. METHODS Retrospective study including 102 patients (107 hips) undergoing traction magnetic resonance arthrography (MRA) of the hip at 1.5 T and subsequent hip arthroscopic FAI surgery performed (01/2016 to 02/2020) with complete follow-up. Clinical outcomes were assessed using the International Hip Outcome Tool (iHOT-12) score. Clinical endpoint for failure was defined as an iHOT-12 of < 60 points or conversion to total hip arthroplasty. MR images were assessed by two radiologists for presence of 9 degenerative lesions including osseous, chondrolabral/ligamentum teres lesions. Uni- and multivariate Cox regression analysis was performed to assess the association between MRI findings and failure of FAI surgery. RESULTS Of the 107 hips, 27 hips (25%) met at least one endpoint at a mean 3.7 ± 0.9 years follow-up. Osteophytic changes of femur or acetabulum (hazard ratio [HR] 2.5-5.0), acetabular cysts (HR 3.4) and extensive cartilage (HR 5.1) and labral damage (HR 5.5) > 2 h on the clockface were univariate risk factors (all p  2 h on the clockface (HR 3.2, p = 0.01), central femoral osteophyte (HR 3.1, p = 0.02), and femoral cartilage damage with ligamentum teres damage (HR 3.0, p = 0.04). CONCLUSION Joint damage detected by preoperative traction MRA is associated with failure 4 years following arthroscopic FAI surgery and yields promise in preoperative risk stratification. CLINICAL RELEVANCE STATEMENT Evaluation of negative predictors on preoperative traction MR arthrography holds the potential to improve risk stratification based on the already present joint degeneration ahead of FAI surgery. KEY POINTS • Osteophytes, acetabular cysts, and extensive chondrolabral damage are risk factors for failure of FAI surgery. • Extensive acetabular cartilage damage, central femoral osteophytes, and combined femoral cartilage and ligamentum teres damage represent independent negative predictors. • Survival rates following hip arthroscopy progressively decrease with increasing prevalence of these three degenerative findings

    Hip MRI in flexion abduction external rotation for assessment of the ischiofemoral interval in patients with hip pain-a feasibility study.

    Get PDF
    OBJECTIVES To assess the feasibility of flexion-abduction-external rotation (FABER) magnetic resonance imaging (MRI) of the hip to visualize changes in the ischiofemoral interval and ability to provoke foveal excursion over the acetabular rim. METHODS IRB-approved retrospective single-center study. Patients underwent non-contrast 1.5-T hip MRI in the neutral and FABER position. Two readers measured the ischiofemoral interval at three levels: proximal/distal intertrochanteric distance and ischiofemoral space. Subgroup analysis was performed for hips with/without high femoral torsion, or quadratus femoris muscle edema (QFME), respectively. A receiver operating curve with calculation of the area under the curve (AUC) for the prediction of QFME was calculated. The presence of foveal excursion in both positions was assessed. RESULTS One hundred ten patients (121 hips, mean age 34 ± 11 years, 67 females) were evaluated. FABER-MRI led to narrowing (both p < .001) of the ischiofemoral interval which decreased more at the proximal (mean decrease by 26 ± 7 mm) than at the distal (6 ± 7 mm) intertrochanteric ridge. With high femoral torsion/ QFME, the ischiofemoral interval was significantly narrower at all three measurement locations compared to normal torsion/no QFME (p < .05). Accuracy for predicting QFME was high with an AUC of .89 (95% CI .82-.94) using a threshold of ≤ 7 mm for the proximal intertrochanteric distance. With FABER-MRI foveal excursion was more frequent in hips with QFME (63% vs 25%; p = .021). CONCLUSION Hip MRI in the FABER position is feasible, visualizes narrowing of the ischiofemoral interval, and can provoke foveal excursion. CRITICAL RELEVANCE STATEMENT FABER MRI may be helpful in diagnosing ischiofemoral impingement and detecting concomitant hip instability by overcoming shortcomings of static MR protocols that do not allow visualization of dynamic changes in the ischiofemoral interval and thus may improve surgical decision making. KEY POINTS • FABER MRI enables visualization of narrowing of the ischiofemoral interval proximal to the lesser trochanter. • Proximal intertrochanteric distance of ≤ 7 mm accurately predicts quadratus femoris muscle edema. • Foveal excursion was more frequent in hips with quadratus femoris muscle edema

    He star evolutionary channel to intermediate-mass binary pulsar PSR J1802-2124

    Full text link
    The intermediate-mass binary pulsars (IMBPs) are characterized by relatively long spin periods (10 - 200 ms) and massive (\ga 0.4 M_{\odot}) white dwarf (WD) companions. Recently, precise mass measurements have been performed for the pulsar and the WD in the IMBP PSR J1802-2124. Some observed properties, such as the low mass of the pulsar, the high mass of the WD, the moderately long spin period, and the tight orbit, imply that this system has undergone a peculiar formation mechanism. In this work, we attempt to simulate the detailed evolutionary history of PSR J1802-2124. We propose that a binary system consisting of a neutron star (NS, of mass 1.3M1.3 M_{\odot}) and an He star (of mass 1.0M1.0 M_{\odot}), and with an initial orbital period of 0.5 d, may have been the progenitor of PSR J1802-2124. Once the He star overflows its Roche lobe, He-rich material is transferred onto the NS at a relatively high rate of 107106Myr1\sim 10^{-7}-10^{-6} M_{\odot}\,\rm yr^{-1}, which is significantly higher than the Eddington accretion rate. A large amount of the transferred material is ejected from the vicinity of the NS by radiation pressure and results in the birth of a mildly recycled pulsar. Our simulated results are consistent with the observed parameters of PSR J1802-2124. Therefore, we argue that the NS + He star evolutionary channel may be responsible for the formation of most IMBPs with orbital periods \la 3 \rm d.Comment: 4 pages, 3 figures, Astronomy and Astrophysics in pres

    Preparation of amino-substituted indenes and 1,4-dihydronaphthalenes using a one-pot multireaction approach: total synthesis of oxybenzo[c]phenanthridine alkaloids

    Get PDF
    Allylic trichloroacetimidates bearing a 2-vinyl or 2-allylaryl group have been designed as substrates for a one-pot, two-step multi-bond-forming process leading to the general preparation of aminoindenes and amino-substituted 1,4-dihydronaphthalenes. The synthetic utility of the privileged structures formed from this one-pot process was demonstrated with the total synthesis of four oxybenzo[c]phenanthridine alkaloids, oxychelerythrine, oxysanguinarine, oxynitidine, and oxyavicine. An intramolecular biaryl Heck coupling reaction, catalyzed using the Hermann–Beller palladacycle was used to effect the key step during the synthesis of the natural products

    Reasons to Be Skeptical about Sentience and Pain in Fishes and Aquatic Invertebrates

    Get PDF
    The welfare of fishes and aquatic invertebrates is important, and several jurisdictions have included these taxa under welfare regulation in recent years. Regulation of welfare requires use of scientifically validated welfare criteria. This is why applying Mertonian skepticism toward claims for sentience and pain in fishes and aquatic invertebrates is scientifically sound and prudent, particularly when those claims are used to justify legislation regulating the welfare of these taxa. Enacting welfare legislation for these taxa without strong scientific evidence is a societal and political choice that risks creating scientific and interpretational problems as well as major policy challenges, including the potential to generate significant unintended consequences. In contrast, a more rigorous science-based approach to the welfare of aquatic organisms that is based on verified, validated and measurable endpoints is more likely to result in “win-win” scenarios that minimize the risk of unintended negative impacts for all stakeholders, including fish and aquatic invertebrates. The authors identify as supporters of animal welfare, and emphasize that this issue is not about choosing between welfare and no welfare for fish and aquatic invertebrates, but rather to ensure that important decisions about their welfare are based on scientifically robust evidence. These ten reasons are delivered in the spirit of organized skepticism to orient legislators, decision makers and the scientific community, and alert them to the need to maintain a high scientific evidential bar for any operational welfare indicators used for aquatic animals, particularly those mandated by legislation. Moving forward, maintaining the highest scientific standards is vitally important, in order to protect not only aquatic animal welfare, but also global food security and the welfare of humans

    Development of the single-mode fiber integral field unit for the RHEA Spectrograph

    Get PDF
    RHEA is a single-mode échelle spectrograph designed to be a replicable and cost effective method of undertaking precision radial velocity measurements. The instrument has a novel fiber feed with an integral field unit injecting into a grid of single-mode fibers reformatted to form a pseudo-slit, increasing throughput and enabling highspatial resolution observations when operating behind Subaru and the SCExAO adaptive optics system. The past 18 months have seen a replacement cable constructed for the instrument to address modal noise caused by closely packed fibers with similar path lengths. Here we detail the cable fabrication procedure, design improvements, increased precision in meeting the required sub-micron optical tolerances, throughput gains, and known remaining issues
    corecore