126 research outputs found

    Towards a Data Link for Unmanned Aviation: DLR Flight Measurement Campaign for C2 Data Link Development

    Get PDF
    Unmanned Aircraft (UA) are expected to play are more and more important role in global aviation during the next years. Besides the “smart” onboard control equipment leading to a certain amount of autonomy of the vehicle, a reliable data link (“Command and Control”, C2-link) is a key enabler for UA. This C2 link is used to exchange information between the UA and the remote pilot, for example positioning information, telemetry data or flight trajectories, respectively. None of the currently available aeronautical communication standards can fulfil the requirements for such a multi-user, multi-point datalink in terms of reliability, flexibility, data integrity, robustness and latency. The German Aerospace Center (DLR) initiated the “C-Band Digital Aeronautical Communication System” (CDACS) project to develop a C-band data link for this purpose. Part of this project is a flight measurement campaign to evaluate initial CDACS waveform designs, besides performing radio channel measurements of the terrestrial ground-air channel in C-band. Detailed knowledge on the behavior of the physical communication channel is crucial for an optimal design of a new communication system. Therefore, it is necessary to perform C-band channel measurements (aka “channel sounding”) and use the collected information to develop a channel model. In turn, this channel model can be used to optimize and evaluate the CDACS waveform design in simulations. The bandwidth used for the C-band channel measurements of this campaign was 50MHz whereas the CDACS waveforms tested spanned a bandwidth of ~1.5MHz. Multiple flight routes and maneuvers are chosen to collect information on different flight scenarios, e. g. take-off and landing, hard banking and en-route. This paper gives a detailed description on how this measurement campaign is setup, what kinds of signals for channel sounding and CDACS waveform testing are transmitted and how the post processing of the data is performed. It will also present an outlook on how the results of the campaign will be used to enhance the initial CDACS design

    Diffusion-Weighted Imaging Hyperintensities in Subtypes of Acute Intracerebral Hemorrhage: Meta-Analysis

    Get PDF
    BACKGROUND AND PURPOSE: Diffusion-weighted imaging (DWI) hyperintensities in intracerebral hemorrhage (ICH) are associated with increased risk of recurrent ICH, cognitive impairment, and death, but whether these lesions are specific to a subtype of ICH remains uncertain. We investigated the association between DWI lesions and ICH subtype and explored the risk factors for DWI lesions. METHODS: In a systematic review of ICH studies, we identified those reporting prevalence of DWI lesions. Two reviewers independently assessed study eligibility and risk of bias and collected data. We determined the pooled prevalence of DWI lesions within 90 days after ICH onset for cerebral amyloid angiopathy- and hypertensive angiopathy-related ICH using random-effects meta-analysis. We calculated odds ratios to compare prevalence of DWI lesions by ICH subtype and to assess risk factors for DWI lesions. RESULTS: Eleven studies (1910 patients) were included. The pooled prevalence of DWI lesions was 18.9% (95% CI, 11.1–26.7) in cerebral amyloid angiopathy- and 21.0% (95% CI, 15.3–26.6) in hypertensive angiopathy-related ICH. There was no difference in the prevalence of DWI lesions between cerebral amyloid angiopathy- (64/292 [21.9%]) and hypertensive angiopathy-related ICH (79/370 [21.4%]; odds ratio, 1.25; 95% CI, 0.73–2.15) in the 5 studies reporting data on both ICH pathogeneses. In all ICH, presence of DWI lesions was associated with neuroimaging features of microangiopathy (leukoaraiosis extension, previous ICH, and presence, and number of microbleeds) but not with vascular risk factors or the use of antithrombotic therapies. CONCLUSIONS: Prevalence of DWI lesions in acute ICH averages 20%, with no difference between cerebral amyloid angiopathy- and hypertensive angiopathy-related ICH. Detection of DWI lesions may add valuable information to assess the progression of the underlying microangiopathy

    Analysis of the Dominant Signal Component of the Air-Ground Channel Based on Measurement Data at C-Band

    Get PDF
    Operating remotely piloted aircraft is not imaginable without a continuous data exchange between the air vehicle and the remote pilot. This data exchange requires reliable data links. One approach for such a data link discussed in the community is a terrestrial system deployed in C-band. A good knowledge of the physical conditions of the communication channel, in this case the air-ground/ground-air channel, is indispensable for the development of wireless data links. Therefore we carried out a 50MHz bandwidth channel sounding campaign with a terrestrial transmitter and an airborne receiver. In this paper we give a detailed description of our campaign setup and the processing of the collected data. The campaign covered several flight scenarios, such as take-off, taxiing, and multiple en-route maneuvers. We furthermore present results on the received power and the amplitude distribution of the first resolvable path of the received signal for the different flight scenarios. We observed significant drops in reception power during certain maneuvers that need to be considered in the design process of a data link for unmanned aviation. Additionally, we show that the amplitude distribution follows the distributions commonly used in statistical channel modeling of wireless channels to some extent. We finally present parameter sets for multiple flight scenarios for scaling the amplitude distributions to allow a statistical channel modeling of the reception power of the first resolvable signal path

    Diode laser based light sources for biomedical applications

    Get PDF
    Diode lasers are by far the most efficient lasers currently available. With the ever-continuing improvement in diode laser technology, this type of laser has become increasingly attractive for a wide range of biomedical applications. Compared to the characteristics of competing laser systems, diode lasers simultaneously offer tunability, high-power emission and compact size at fairly low cost. Therefore, diode lasers are increasingly preferred in important applications, such as photocoagulation, optical coherence tomography, diffuse optical imaging, fluorescence lifetime imaging, and terahertz imaging. This review provides an overview of the latest development of diode laser technology and systems and their use within selected biomedical applications

    A Survey of Air-to-Ground Propagation Channel Modeling for Unmanned Aerial Vehicles

    Full text link
    In recent years, there has been a dramatic increase in the use of unmanned aerial vehicles (UAVs), particularly for small UAVs, due to their affordable prices, ease of availability, and ease of operability. Existing and future applications of UAVs include remote surveillance and monitoring, relief operations, package delivery, and communication backhaul infrastructure. Additionally, UAVs are envisioned as an important component of 5G wireless technology and beyond. The unique application scenarios for UAVs necessitate accurate air-to-ground (AG) propagation channel models for designing and evaluating UAV communication links for control/non-payload as well as payload data transmissions. These AG propagation models have not been investigated in detail when compared to terrestrial propagation models. In this paper, a comprehensive survey is provided on available AG channel measurement campaigns, large and small scale fading channel models, their limitations, and future research directions for UAV communication scenarios

    Risk of intracranial haemorrhage and ischaemic stroke after convexity subarachnoid haemorrhage in cerebral amyloid angiopathy: international individual patient data pooled analysis

    Get PDF
    OBJECTIVE: To investigate the frequency, time-course and predictors of intracerebral haemorrhage (ICH), recurrent convexity subarachnoid haemorrhage (cSAH), and ischemic stroke after cSAH associated with cerebral amyloid angiopathy (CAA). METHODS: We performed a systematic review and international individual patient-data pooled analysis in patients with cSAH associated with probable or possible CAA diagnosed on baseline MRI using the modified Boston criteria. We used Cox proportional hazards models with a frailty term to account for between-cohort differences. RESULTS: We included 190 patients (mean age 74.5 years; 45.3% female) from 13 centers with 385 patient-years of follow-up (median 1.4 years). The risks of each outcome (per patient-year) were: ICH 13.2% (95% CI 9.9-17.4); recurrent cSAH 11.1% (95% CI 7.9-15.2); combined ICH, cSAH, or both 21.4% (95% CI 16.7-26.9), ischemic stroke 5.1% (95% CI 3.1-8) and death 8.3% (95% CI 5.6-11.8). In multivariable models, there is evidence that patients with probable CAA (compared to possible CAA) had a higher risk of ICH (HR 8.45, 95% CI 1.13-75.5, p = 0.02) and cSAH (HR 3.66, 95% CI 0.84-15.9, p = 0.08) but not ischemic stroke (HR 0.56, 95% CI 0.17-1.82, p = 0.33) or mortality (HR 0.54, 95% CI 0.16-1.78, p = 0.31). CONCLUSIONS: Patients with cSAH associated with probable or possible CAA have high risk of future ICH and recurrent cSAH. Convexity SAH associated with probable (vs possible) CAA is associated with increased risk of ICH, and cSAH but not ischemic stroke. Our data provide precise risk estimates for key vascular events after cSAH associated with CAA which can inform management decisions

    Mammalian cell transfection: the present and the future

    Get PDF
    Transfection is a powerful analytical tool enabling study of the function of genes and gene products in cells. The transfection methods are broadly classified into three groups; biological, chemical, and physical. These methods have advanced to make it possible to deliver nucleic acids to specific subcellular regions of cells by use of a precisely controlled laser-microcope system. The combination of point-directed transfection and mRNA transfection is a new way of studying the function of genes and gene products. However, each method has its own advantages and disadvantages so the optimum method depends on experimental design and objective

    Non-monotonic changes in clonogenic cell survival induced by disulphonated aluminum phthalocyanine photodynamic treatment in a human glioma cell line

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Photodynamic therapy (PDT) involves excitation of sensitizer molecules by visible light in the presence of molecular oxygen, thereby generating reactive oxygen species (ROS) through electron/energy transfer processes. The ROS, thus produced can cause damage to both the structure and the function of the cellular constituents resulting in cell death. Our preliminary investigations of dose-response relationships in a human glioma cell line (BMG-1) showed that disulphonated aluminum phthalocyanine (AlPcS<sub>2</sub>) photodynamically induced loss of cell survival in a concentration dependent manner up to 1 μM, further increases in AlPcS<sub>2</sub>concentration (>1 μM) were, however, observed to decrease the photodynamic toxicity. Considering the fact that for most photosensitizers only monotonic dose-response (survival) relationships have been reported, this result was unexpected. The present studies were, therefore, undertaken to further investigate the concentration dependent photodynamic effects of AlPcS<sub>2</sub>.</p> <p>Methods</p> <p>Concentration-dependent cellular uptake, sub-cellular localization, proliferation and photodynamic effects of AlPcS<sub>2 </sub>were investigated in BMG-1 cells by absorbance and fluorescence measurements, image analysis, cell counting and colony forming assays, flow cytometry and micronuclei formation respectively.</p> <p>Results</p> <p>The cellular uptake as a function of extra-cellular AlPcS<sub>2 </sub>concentrations was observed to be biphasic. AlPcS<sub>2 </sub>was distributed throughout the cytoplasm with intense fluorescence in the perinuclear regions at a concentration of 1 μM, while a weak diffuse fluorescence was observed at higher concentrations. A concentration-dependent decrease in cell proliferation with accumulation of cells in G<sub>2</sub>+M phase was observed after PDT. The response of clonogenic survival after AlPcS<sub>2</sub>-PDT was non-monotonic with respect to AlPcS<sub>2 </sub>concentration.</p> <p>Conclusions</p> <p>Based on the results we conclude that concentration-dependent changes in physico-chemical properties of sensitizer such as aggregation may influence intracellular transport and localization of photosensitizer. Consequent modifications in the photodynamic induction of lesions and their repair leading to different modes of cell death may contribute to the observed non-linear effects.</p

    Video monitoring of neovessel occlusion induced by photodynamic therapy with verteporfin (Visudyne®), in the CAM model

    Get PDF
    The aim of the present study was to monitor photodynamic angioocclusion with verteporfin in capillaries. Details of this process were recorded under a microscope in real-time using a high-sensitivity video camera. A procedure was developed based on intravenous (i.v.) injection of a light-activated drug, Visudyne®, into the chorioallantoic membrane (CAM) of a 12-day-old chicken embryo. The effect of light activation was probed after 24 h by i.v. injection of a fluorescent dye (FITC dextran), and analysis of its fluorescence distribution. The angioocclusive effect was graded based on the size of the occluded vessels, and these results were compared with clinical observations. The time-resolved thrombus formation taking place in a fraction of the field of view was video recorded using a Peltier-cooled CCD camera. This vessel occlusion in the CAM model was reproducible and, in many ways, similar to that observed in the clinical use of verteporfin. The real-time video recording permitted the monitoring of platelet aggregation and revealed size-selective vascular closure as well as some degree of vasoconstriction. Platelets accumulated at intravascular junctions within seconds after verteporfin light activation, and capillaries were found to be closed 15 min later at the applied conditions. Larger-diameter vessels remained patent. Repetition of these data with a much more sensitive camera revealed occlusion of the treated area after 5 min with doses of verteporfin and light similar to those used clinically. Consequently, newly developed light-activated drugs can now be studied under clinically relevant conditions
    corecore