2,420 research outputs found

    Improving Tracer Particle Surface Properties for Wind Tunnel Research

    Get PDF
    The surface properties of micron size polystyrene latex microspheres (PSLs) modified with quaternary alkylammonium (QA) surfactants were investigated, with a focus on the relationship between surface chemistry and adhesion. These investigations were motivated by the need to develop non-fouling tracer particles for wind tunnel studies. The goals were to relate the work of adhesion between particles and substrates to the type and amount of QA modifier in order to optimize the performance of PSL tracers. Surfactant-free emulsion polymerization (SFEP) can produce PSLs for wind tunnel tracers. Covalentlybound charged groups (derived from the initiator) stabilize PSL surfaces in water. This work used PSLs with anionic surface groups. Previous studies indicated that surface-bound charged groups on PSLs have a significant impact on their interfacial energy. Modifying charged surface groups therefore offers a method to modulate PSL interfacial properties. In this work, PSLs and films were modified by adsorption of QA surfactants

    CHAP Enhances Versatility in Colloidal Probe Fabrication

    Get PDF
    A colloidal probe, comprising a colloidal particle attached to an atomic force microscope cantilever, is employed to measure directly interaction forces between the particle and a surface. It is possible to change or even destroy a particle while attaching it to a cantilever, thus limiting the types of systems to which the colloidal probe technique may be applied. Here we present the Controlled Heating and Alignment Platform (CHAP) for fabricating colloidal probes without altering the original characteristics of the attached particle. The CHAP applies heat directly to the atomic force microscope chip to rapidly and precisely control cantilever temperature. This minimizes particle heating and enables control over the viscosity of thermoplastic adhesive, to prevent it from contaminating the particle surface. 3D-printed components made the CHAP compatible with standard optical microscopes and streamlined the fabrication process while increasing the platforms versatility. Using the CHAP with a thermoplastic wax adhesive, colloidal probes were fabricated using polystyrene and silica particles between 0.7 and 40 m in diameter. We characterized the properties and interactions of the adhesive and particles, as well as the properties of the completed probes, to demonstrate the retention of particle features throughout fabrication. Pull-off tests with CHAPs probes measured adhesive force values in the expected ranges and demonstrated that particles were firmly attached to the cantilevers

    Reduction of Wind Tunnel Contamination During Flow Visualization Experiments Using Polystyrene Microspheres

    Get PDF
    Evaluation of novel methods and materials for seeding tracer particles for particle image velocimetry (PIV) was carried out in the Basic Aerodynamic Research Tunnel (BART) at NASAs Langley Research Center (LaRC). Seeding of polystyrene latex microspheres (PSLs) from ethanol/water suspensions and from the dry state was carried out using custom built seeders. PIV data generated using the novel methods were found to be in general agreement with data collected using the current seeding methods. Techniques for assessing PSL fouling of wind tunnel surfaces were identified and refined. Initial results suggest that dry seeding PSLs may allow comparable data quality to wet seeding while reducing wind tunnel screen fouling. Results also indicate that further developments to the dry seeding system should focus on increasing single particle flux into the wind tunnel. Modifications to PSLs and seeding equipment to achieve this have been identified and are discussed

    Measuring Work of Adhesion of Polystyrene Microspheres

    Get PDF
    Particle adhesion is relevant in fields ranging from aerospace and energy to civil engineering and medicine. The functions of aerodynamic surfaces, heat exchangers, solar panels, ventilation systems, and blood vessels are affected by the buildup of particulates on their surfaces. Direct measurement of the adhesive force between a particle and a surface is key to understanding and mitigating particle fouling. Approaches such as the Johnson-Kendall-Roberts (JKR) and Derjaguin-Muller-Toporov (DMT) models offer a first approximation of the forces involved but do not account for non-idealities like roughness or plastic deformation. Experimental measurements of adhesive forces often deviate significantly from predictions. One approach to measure adhesion is the colloidal probe technique, which uses a particle attached to the tip of an atomic force microscope (AFM) cantilever. The particle is touched to a surface and then withdrawn and a pull-off force (FPO) determined by cantilever deflection. FPO can be used to estimate work of adhesion (Wa) and other properties from existing models. We describe a new method for producing colloidal probes using wax as an adhesive to attach micrometer-scale spheres to AFM tips. This method can be used with a range of particles and minimizes the potential for changes to the particle surface chemistry or geometry from exposure to heat, chemicals, radiation, or external forces. Particle attachment to AFM tips is robust and reversible, allowing old particles to be replaced with new ones in a few minutes. Pull-off measurements using polystyrene (PS) particles, pristine and modified with myristyltrimethylammonium bromide (14-TAB), were collected from various substrates to demonstrate the viability of this technique and investigate the impact of particle surface modification

    Further Insight into the Mechanism of Poly(styrene-co-methyl methacrylate) Microsphere Formation

    Get PDF
    Polymeric microspheres have been utilized in a broad range of applications ranging from chromatographic separation techniques to analysis of air flow over aerodynamic surfaces. The preparation of microspheres from many different polymer families has consequently been extensively studied using a variety of synthetic approaches. Although there are a variety of methods of synthesis for polymeric microspheres, free-radical initiated emulsion polymerization is one of the most common techniques. In this work, poly(styrene-co-methyl methacrylate) microspheres were synthesized via surfactant-free emulsion polymerization. The effect of comonomer composition and addition time on particle size distribution, particle formation, and particle morphology were investigated. Particles were characterized using dynamic light scattering (DLS) and scanning electron microscopy (SEM) to gain further insight into particle size and size distributions. Reaction kinetics were analyzed alongside of characterization results. A particle formation mechanism for poly(styrene-co-methyl methacrylate) microspheres was proposed based on characterization results and known reaction kinetics

    Defining Accelerometer Thresholds for Activity Intensities in Adolescent Girls

    Get PDF
    Purpose - To derive a regression equation that estimates metabolic equivalent (MET) from accelerometer counts, and to define thresholds of accelerometer counts that can be used to delineate sedentary, light, moderate, and vigorous activity. Methods - Seventy-four healthy 8th grade girls, age 13-14 yr, were recruited from urban areas of Baltimore, MD, Minneapolis/St. Paul, MN, and Columbia, SC, to participate in the study. Accelerometer and oxygen consumption (VO2) data for 10 activities that varied in intensity from sedentary (e.g., TV watching) to vigorous (e.g., running) were collected. While performing these activities, the girls wore two accelerometers, a heart rate monitor and a Cosmed K4b2 portable metabolic unit for measurement of VO2. A random-coefficients model was used to estimate the relationship between accelerometer counts and VO2. Activity thresholds were defined by minimizing the false positive and false negative classifications. Results - The activities provided a wide range in VO2 (3-36 mLĀ·kg-1Ā·min-1) with a correspondingly wide range in accelerometer counts (1-3928 countsĀ·30 s-1). The regression line for MET score versus counts was MET=2.01+0.00171 (countsĀ·30 s-1) (mixed model R2=0.84, SEE=1.36). A threshold of 1500 countsĀ·30 s-1 defined the lower end of the moderate intensity (~4.6 METs) range of physical activity. That cutpoint distinguished between slow and brisk walking, and gave the lowest number of false positive and false negative classifications. The threshold ranges for sedentary, light, moderate, and vigorous physical activity were found to be 0-50, 51-1499, 1500-2600, and \u3e2600 countsĀ·30 s-1, respectively. Conclusion - The developed equation and these activity thresholds can be used for prediction of MET score from accelerometer counts and participation in various intensities of physical activity in adolescent girls

    Comparison of Two Approaches to Structured Physical Activity Surveys of Adolescents

    Get PDF
    Purpose - To compare the test-retest reliability, convergent validity, and overall feasibility/usability of activity-based (AB) and time-based (TB) approaches for obtaining self-reported moderate-to-vigorous physical activity (MVPA) from adolescents. Methods - Adolescents (206 females and 114 males) completed two 3-d physical activity recalls using the AB and TB surveys, which contained identical lists of physical activities. The participants wore an MTI ActigraphĀ® accelerometer for the same period. Results - The TB instrument took about 3 min longer to complete (P=0.022). Overall 2-d test-retest correlations for MVPA were similar for the two surveys (r=0.676 and 0.667), but the girls had higher reliability on the AB survey than the boys (girls: r=0.713; boys: r=0.568). The overall 3-d correlations for MVPA surveys and Actigraph counts varied by gender (girls: AB=0.265 vs TB=0.314; boys: AB=0.340 vs TB=0.277). Correlations for vigorous physical activity and Actigraph counts were higher for the AB than for the TB (r=0.281 vs 0.162). As the interval between completing the surveys and the days being recalled increased, reliability and validity were lower, especially for the AB survey. Conclusion - For both genders, either approach is acceptable for obtaining MVPA information on a single day, but the TB approach appears to be slightly favored over the AB approach for obtaining multiple days of MVPA. A 3-d recall period appears to be too long for accurate recall of MVPA information from either instrument. For both genders, the surveys overestimate activity levels; thus, self-reports should be supplemented with objective data
    • ā€¦
    corecore