234 research outputs found

    Longitudinal Study of Optic Disk Perfusion and Retinal Structure in Leber's Hereditary Optic Neuropathy

    Get PDF
    PURPOSE. The purpose of this study was to evaluate optic disk perfusion and neural retinal structure in patients with subacute Leber's hereditary optic neuropathy (LHON) and LHON carriers, as compared with healthy controls. METHODS. This study included 8 patients with LHON in the subacute stage, 10 asymptomatic carriers of a LHON-associated mitochondrial DNA mutation, and 40 controls. All subjects underwent measurement of the retinal nerve fiber layer (RNFL) thickness, the ganglion cell-inner plexiform layer (GCIPL) thickness using optical coherence tomography and optic disk microvascular perfusion (Mean Tissue [MT]) using laser speckle flowgraphy (LSFG). Patients were re-examined after a median interval of 3 months from the baseline visit. RESULTS. LHON carriers had higher values of RNFL thickness, GCIPL thickness, and disk area than controls (P < 0.05), whereas MT was not different between the two groups (P = 0.936). Median MT and RNFL thickness were 32% and 15% higher in the early subacute stage of the disease than in controls (P < 0.001 and P = 0.001). MT declined below the values of controls during the late subacute stage (P = 0.024), whereas RNFL thickness declined later during the dynamic stage (P < 0.001). GCIPL thickness was lower in patients with LHON than in controls independently of the stage of the disease (P < 0.001). CONCLUSIONS. The high blood flow at the optic disk during the early subacute stage may be the consequence of vasodilation due to nitric oxide release as compensation to mitochondrial impairment. Optic disk perfusion as measured by LSFG is a promising biomarker for LHON diagnosis and monitoring as well as an objective outcome measure for assessing response to therapies

    An optical coherence photoacoustic microscopy system using a fiber optic sensor

    Get PDF
    In this work, a novel fiber optic sensor based on Fabry-Pérot interferometry is adopted in an optical coherence photoacoustic microscopy (OC-PAM) system to enable high-resolution in vivo imaging. The complete OC-PAM system is characterized using the fiber optic sensor for photoacoustic measurement. After characterization, the performance of the system is evaluated by imaging zebrafish larvae in vivo. With a lateral resolution of 3.4 μm and an axial resolution of 3.7 μm in air, the optical coherence microscopy subsystem visualizes the anatomy of the zebrafish larvae. The photoacoustic microscopy subsystem reveals the vasculature of the zebrafish larvae with a lateral resolution of 1.9 μm and an axial resolution of 37.3 μm. As the two modalities share the same sample arm, we obtain inherently co-registered morphological and vascular images. This OC-PAM system provides comprehensive information on the anatomy and vasculature of the zebrafish larvae. Featuring compactness, broad detection bandwidth, and wide detection angle, the fiber optic sensor enables a large field of view with a static sensor position. We verified the feasibility of the fiber optic sensor for dual-modality in vivo imaging. The OC-PAM system, as a non-invasive imaging method, demonstrates its superiority in the investigation of zebrafish larvae, an animal model with increasing significance in developmental biology and disease research. This technique can also be applied for functional as well as longitudinal studies in the future

    Deep learning system to predict the 5-year risk of high myopia using fundus imaging in children

    Get PDF
    Our study aims to identify children at risk of developing high myopia for timely assessment and intervention, preventing myopia progression and complications in adulthood through the development of a deep learning system (DLS). Using a school-based cohort in Singapore comprising 998 children (aged 6-12 years old), we train and perform primary validation of the DLS using 7456 baseline fundus images of 1878 eyes; with external validation using an independent test dataset of 821 baseline fundus images of 189 eyes together with clinical data (age, gender, race, parental myopia, and baseline spherical equivalent (SE)). We derive three distinct algorithms - image, clinical, and mix (image + clinical) models to predict high myopia development (SE ≤ -6.00 diopter) during teenage years (5 years later, age 11-17). Model performance is evaluated using the area under the receiver operating curve (AUC). Our image models (Primary dataset AUC 0.93-0.95; Test dataset 0.91-0.93), clinical models (Primary dataset AUC 0.90-0.97; Test dataset 0.93-0.94) and mixed (image + clinical) models (Primary dataset AUC 0.97; Test dataset 0.97-0.98) achieve clinically acceptable performance. The addition of 1 year SE progression variable has minimal impact on the DLS performance (clinical model AUC 0.98 versus 0.97 in the primary dataset, 0.97 versus 0.94 in the test dataset; mixed model AUC 0.99 versus 0.97 in the primary dataset, 0.95 versus 0.98 in test dataset). Thus, our DLS allows prediction of the development of high myopia by teenage years amongst school-going children. This has potential utility as a clinical decision support tool to identify "at-risk" children for early intervention.info:eu-repo/semantics/publishedVersio

    Ocular Blood Flow Measurements in Healthy White Subjects Using Laser Speckle Flowgraphy

    Get PDF
    Purpose. To assess the feasibility and reliability of Laser Speckle Flowgraphy (LSFG) to measure ocular perfusion in a sample of healthy white subjects and to elucidate the age-dependence of the parameters obtained. Methods: This cross-sectional study included 80 eyes of 80 healthy, non-smoking white subjects of Western European descent between 19 and 79 years of age. A commercial LSFG instrument was applied to measure ocular blood flow at the optic nerve head (ONH) three successive times before and after pharmacological pupil dilation. The mean blur rate (MBR), a measure of relative blood flow velocity, was obtained for different regions of the ONH. Eight parameters of ocular perfusion derived from the pulse-waveform analysis of MBR including blowout time (BOT) and falling rate (FR) were also recorded. Results Artifact-free LSFG images meeting the quality criteria for automated image analysis were obtainable in 93.8% without pupil dilation and in 98.8% with pharmacological pupil dilation. Measurements of MBR showed excellent repeatability with intraclass correlation coefficients >= 0.937 and were barely affected by pupil dilation. The majority of pulse-waveform derived variables exhibited equally high repeatability. MBR-related blood flow indices exhibited significant age dependence (p<0.001). FR (r = 0.747, p<0.001) and BOT (r = -0.714, p<0.001) most strongly correlated with age. Conclusions: LSFG represents a reliable method for the quantitative assessment of ocular blood flow in white subjects. Our data affirms that the LSFG-derived variables FR and BOT may be useful biomarkers for age-related changes in ocular perfusion

    Candesartan Attenuates Diabetic Retinal Vascular Pathology by Restoring Glyoxalase-I Function

    Get PDF
    This is an uncopyedited electronic version of an article accepted for publication in Diabetes. The American Diabetes Association, publisher of Diabetes, is not responsible for any errors or omissions in this version of the manuscript or any version derived from it by third parties. The definitive publisher-authenticated version will be available in a future issue of Diabetes in print and online a

    Intraocular pressure and aqueous humor flow during a euglycemic-hyperinsulinemic clamp in patients with type 1 diabetes and microvascular complications

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Microvascular complications, including retinopathy and nephropathy are seen with type 1 diabetes. It is unknown whether functional changes in aqueous humor flow or intraocular pressure (IOP) develop in parallel with these complications. This study was designed to test the hypothesis that clinical markers of microvascular complications coexist with the alteration in aqueous humor flow and IOP.</p> <p>Methods</p> <p>Ten patients with type 1 diabetes and ten healthy age- and weight-matched controls were studied. Aqueous flow was measured by fluorophotometry during a hyperinsulinemic-euglycemic clamp (insulin 2 mU/kg/min). Intraocular pressure was measured by tonometry at -10, 90 and 240 minutes from the start of the clamp, and outflow facility was measured by tonography at 240 minutes.</p> <p>Results</p> <p>During conditions of identical glucose and insulin concentrations, mean aqueous flow was lower by 0.58 μl/min in the diabetes group compared to controls (2.58 ± 0.65 versus 3.16 ± 0.66 μl/min, respectively, mean ± SD, p = 0.07) but statistical significance was not reached. Before the clamp, IOP was higher in the diabetes group (22.6 ± 3.0 mm Hg) than in the control group (19.3 ± 1.8 mm Hg, p = 0.01) but at 90 minutes into the clamp, and for the remainder of the study, IOP was reduced in the diabetes group to the level of the control group. Ocular pulse amplitude and outflow facility were not different between groups. Systolic blood pressure was significantly higher in the diabetes group, but diastolic and mean arterial pressures were not different.</p> <p>Conclusions</p> <p>We conclude that compared to healthy participants, patients with type 1 diabetes having microalbuminuria and retinopathy have higher IOPs that are normalized by hyperinsulinemia. During the clamp, a reduction in aqueous flow was not statistically significant.</p
    corecore