240 research outputs found

    The 10 Tesla muSR instrument: detector solutions

    Get PDF
    Solutions to the detector system of the High-Field muSR instrument at the Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical requirements are fulfilled through the application of Geiger-mode Avalanche Photodiodes.Comment: 6 pages, 4 figure

    Visual exploration of climate variability changes using wavelet analysis

    Get PDF
    Due to its nonlinear nature, the climate system shows quite high natural variability on different time scales, including multiyear oscillations such as the El NiËśno Southern Oscillation phenomenon. Beside a shift of the mean states and of extreme values of climate variables, climate change may also change the frequency or the spatial patterns of these natural climate variations. Wavelet analysis is a well established tool to investigate variability in the frequency domain. However, due to the size and complexity of the analysis results, only few time series are commonly analyzed concurrently. In this paper we will explore different techniques to visually assist the user in the analysis of variability and variability changes to allow for a holistic analysis of a global climate model data set consisting of several variables and extending over 250 years. Our new framework and data from the IPCC AR4 simulations with the coupled climate model ECHAM5/MPI-OM are used to explore the temporal evolution of El NiËśno due to climate change

    A Robust and Ultra-Fast Short Circuit Detection in Half-Bridge Using Stray Voltage Capture:Applied in Electromagnetic Suspension

    Get PDF
    The paper proposes a robust and ultra-fast short circuit detection method based on the voltage dip in the half-bridge due to the presence of stray inductance. For the application of the inverter in electromagnetic suspension, the short circuit is detected in less than 100 ns, which is a promising solution against the Fault Under Load due to a Single-Event Burnout failure type

    Raf kinases mediate the phosphorylation of eukaryotic translation elongation factor 1A and regulate its stability in eukaryotic cells

    Get PDF
    We identified eukaryotic translation elongation factor 1A (eEF1A) Raf-mediated phosphorylation sites and defined their role in the regulation of eEF1A half-life and of apoptosis of human cancer cells. Mass spectrometry identified in vitro S21 and T88 as phosphorylation sites mediated by B-Raf but not C-Raf on eEF1A1 whereas S21 was phosphorylated on eEF1A2 by both B- and C-Raf. Interestingly, S21 belongs to the first eEF1A GTP/GDP-binding consensus sequence. Phosphorylation of S21 was strongly enhanced when both eEF1A isoforms were preincubated prior the assay with C-Raf, suggesting that the eEF1A isoforms can heterodimerize thus increasing the accessibility of S21 to the phosphate. Overexpression of eEF1A1 in COS 7 cells confirmed the phosphorylation of T88 also in vivo. Compared with wt, in COS 7 cells overexpressed phosphodeficient (A) and phospho-mimicking (D) mutants of eEF1A1 (S21A/D and T88A/D) and of eEF1A2 (S21A/D), resulted less stable and more rapidly proteasome degraded. Transfection of S21 A/D eEF1A mutants in H1355 cells increased apoptosis in comparison with the wt isoforms. It indicates that the blockage of S21 interferes with or even supports C-Raf induced apoptosis rather than cell survival. Raf-mediated regulation of this site could be a crucial mechanism involved in the functional switching of eEF1A between its role in protein biosynthesis and its participation in other cellular processes

    Cholesterol-crystal embolism presenting with delayed graft function and impaired long-term function in renal transplant recipients: two case reports

    Get PDF
    Introduction Impaired renal function and/or pre-existing atherosclerosis in the deceased donor increase the risk of delayed graft function and impaired long-term renal function in kidney transplant recipients. Case presentation We report delayed graft function occurring simultaneously in two kidney transplant recipients, aged 57-years-old and 39-years-old, who received renal allografts from the same deceased donor. The 62-year-old donor died of cardiac arrest during an asthmatic state. Renal-allograft biopsies performed in both kidney recipients because of delayed graft function revealed cholesterol-crystal embolism. An empiric statin therapy in addition to low-dose acetylsalicylic acid was initiated. After 10 and 6 hemodialysis sessions every 48 hours, respectively, both renal allografts started to function. Glomerular filtration rates at discharge were 26 ml/min/1.73 m2 and 23.9 ml/min/1.73 m2, and remained stable in follow-up examinations. Possible donor and surgical procedure-dependent causes for cholesterol-crystal embolism are discussed. Conclusion Cholesterol-crystal embolism should be considered as a cause for delayed graft function and long-term impaired renal allograft function, especially in the older donor population

    Amplification of GaSb-Based Diode Lasers in an Erbium-Doped Fluoride Fibre Amplifier

    Get PDF
    Building upon recent advances in GaSb-based diode lasers and Er-doped fluoride fibre technologies, this article demonstrates for the first time the fibre-based amplification of mid-infrared diode lasers in the wavelength range around 2.78 ÎĽ\mum. The laser setup consists of a GaSb-based diode laser and a single-stage Er-doped fibre amplifier. Amplification is investigated for continuous wave (CW) and ns-pulsed input signals, generated by gain-modulation of the GaSb-based seed lasers. The experimental results include the demonstration of output powers up to 0.9 W, pulse durations as short as 20 ns, and pulse repetition rates up to 1 MHz. Additionally, the amplification of commercial and custom-made GaSb-based seed lasers is compared and the impact of different fibre end-cap materials on laser performance is analysed

    Static and Dynamic Lung Volumes in Swimmers and Their Ventilatory Response to Maximal Exercise

    Get PDF
    Purpose While the static and dynamic lung volumes of active swimmers is often greater than the predicted volume of similarly active non-swimmers, little is known if their ventilatory response to exercise is also different. Methods Three groups of anthropometrically matched male adults were recruited, daily active swimmers (n = 15), daily active in fields sport (Rugby and Football) (n = 15), and recreationally active (n = 15). Forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and maximal voluntary ventilation (MVV) was measured before and after exercise to volitional exhaustion. Results Swimmers had significantly larger FVC (6.2 ± 0.6 l, 109 ± 9% pred) than the other groups (5.6 ± 0.5 l, 106 ± 13% pred, 5.5 ± 0.8, 99% pred, the sportsmen and recreational groups, respectively). FEV1 and MVV were not different. While at peak exercise, all groups reached their ventilatory reserve (around 20%), the swimmers had a greater minute ventilation rate than the recreational group (146 ± 19 vs 120 ± 87 l/min), delivering this volume by breathing deeper and slower. Conclusions The swimmers utilised their larger static volumes (FVC) differently during exercise by meeting their ventilation volume through long and deep breaths

    Cardiovascular magnetic resonance in pericardial diseases

    Get PDF
    The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR) is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases
    • …
    corecore