17 research outputs found

    Automated Motion Analysis of Bony Joint Structures from Dynamic Computer Tomography Images: A Multi-Atlas Approach

    Get PDF
    Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1◦. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine

    Finite element analysis of the effect of cementing concepts on implant stability and cement fatigue failure

    Get PDF
    Background and purpose Two contradictory cementing techniques (using an undersized stem versus a canal-filling stem) can both lead to excellent survival rates, a phenomenon known as the “French paradox”. Furthermore, previous studies have indicated that the type of bone supporting the cement mantle may affect implant survival. To further evaluate the mechanical consequences of variations in cementing technique, we studied the effect of implant size and type of bone supporting the cement mantle on the mechanical performance of cemented total hip arthroplasty, using finite element analysis

    The use of cardiac CT acquisition mode for dynamic musculoskeletal imaging

    Get PDF
    Objectives To quantitatively evaluate the impact of a cardiac acquisition CT mode on motion artifacts in comparison to a conventional cine mode for dynamic musculoskeletal (MSK) imaging. Methods A rotating PMMA phantom with air-filled holes drilled at varying distances from the disk center corresponding to linear hole speeds of 0.75 cm/s, 2.0 cm/s, and 3.6 cm/s was designed. Dynamic scans were obtained in cardiac and cine modes while the phantom was rotating at 48°/s in the CT scanner. An automated workflow to compute the Jaccard distance (JD) was established to quantify degree of motion artifacts in the reconstructed phantom images. JD values between the cardiac and cine scan modes were compared using a paired sample t-test. In addition, three healthy volunteers were scanned with both modes during a cyclic flexion–extension motion of the knee and analysed using the proposed metric. Results For all hole sizes and speeds, the cardiac scan mode had significantly lower (p-value <0.001) JD values. (0.39 [0.32–0.46]) i.e less motion artifacts in comparison to the cine mode (0.72 [0.68–0.76]). For both modes, a progressive increase in JD was also observed as the linear speed of the holes increased from 0.75 cm/s to 3.6 cm/s. The dynamic images of the three healthy volunteers showed less artifacts when scanned in cardiac mode compared to cine mode, and this was quantitatively confirmed by the JD values. Conclusions A cardiac scan mode could be used to study dynamic musculoskeletal phenomena especially of fast-moving joints since it significantly minimized motion artifacts

    Automated Motion Analysis of Bony Joint Structures from Dynamic Computer Tomography Images: A Multi-Atlas Approach

    Get PDF
    Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1°. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine

    Custom-made triflanged acetabular components in the treatment of major acetabular defects. Short-term results and clinical experience

    No full text
    We report on the Belgian experience with the aMace® custom-made triflange acetabular component in revision total hip arthroplasty between September 2009 and November 2014. We focused on (1) the complexity of the preoperative planning and reimbursement procedure; (2) the surgical problems and operative experience; and (3) the early outcome. We collected 20 patients’ reviews and 22 surgeons’ reviews, with a mean follow-up of 25 months. The preoperative planning and reimbursement procedures were rated as time-consuming and cumbersome. In 6/22 cases, the operation was difficult or very difficult. Technical problems occurred in 8/22 cases, including problematic fitting in four. However, all aMace® components could be implanted successfully. The mean postoperative Harris Hip Score (HHS) was 68/100; patients’ satisfaction was high and most patients experienced no or mild pain. Complications occurred in 8/22 cases, half of them dislocations. The aMace® implant can provide a solution for complex acetabular revisions. As dislocations were common, the use of dual-mobility cups should be considered. Because of the high cost and the lack of bone stock restoration, we suggest using custom-made triflange acetabular implants only in cases with large cavitational and segmental defects, which would be difficult to reconstruct with alternative methods

    Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA)

    No full text
    Background and purpose — We developed a marker-free automated CT-based spatial analysis (CTSA) method to detect stem-bone migration in consecutive CT datasets and assessed the accuracy and precision in vitro. Our aim was to demonstrate that in vitro accuracy and precision of CTSA is comparable to that of radiostereometric analysis (RSA). Material and methods — Stem and bone were segmented in 2 CT datasets and both were registered pairwise. The resulting rigid transformations were compared and transferred to an anatomically sound coordinate system, taking the stem as reference. This resulted in 3 translation parameters and 3 rotation parameters describing the relative amount of stem-bone displacement, and it allowed calculation of the point of maximal stem migration. Accuracy was evaluated in 39 comparisons by imposing known stem migration on a stem-bone model. Precision was estimated in 20 comparisons based on a zero-migration model, and in 5 patients without stem loosening. Results — Limits of the 95% tolerance intervals (TIs) for accuracy did not exceed 0.28 mm for translations and 0.20° for rotations (largest standard deviation of the signed error (SDSE): 0.081 mm and 0.057°). In vitro, limits of the 95% TI for precision in a clinically relevant setting (8 comparisons) were below 0.09 mm and 0.14° (largest SDSE: 0.012 mm and 0.020°). In patients, the precision was lower, but acceptable, and dependent on CT scan resolution. Interpretation — CTSA allows detection of stem-bone migration with an accuracy and precision comparable to that of RSA. It could be valuable for evaluation of subtle stem loosening in clinical practice

    Effect of anatomical variability on stress-shielding induced by short calcar-guided stems: Automated finite element analysis of 90 femora

    No full text
    Short stem hip implants are becoming increasingly popular since they preserve bone stock and presumably reduce stress-shielding. However, concerns remain whether they are suitable for a wide range of patients with varying anatomy. The aim of this study was to investigate how femoral anatomy influences stress-shielding induced by a short calcar-guided stem across a set of 90 CT-based femur models. A computational tool was developed that automatically selected the optimal size and position of the stem. Finite element models of the intact and implanted femurs were constructed and subjected to walking loads. Stress-shielding was evaluated in relevant volumes of interest of the proximal femur. After a detailed anatomical analysis, linear regression was performed to find potential correlations between anatomy and stress-shielding. Stress-shielding was found to be highest in the proximal regions on the medial and posterior side. A highly significant negative relationship was observed between stress-shielding and bone density; a strong positive relationship was observed with stem size and the valgus orientation of the stem with respect to the femur. The results reveal how anatomy influences stress-shielding, and they highlight the importance of evaluating new implant designs across a large population taking into account the anatomical variability. The study demonstrates that such large population studies can be conducted in an efficient way using an automated workflow. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:1-8, 2019.status: publishe