38 research outputs found

    Coexisting large and small vessel disease in patients with ischemic stroke of undetermined cause

    Get PDF
    Background and Purpose: Large artery atherosclerosis (LAA) and small vessel disease (SVD) share common risk factors for stroke. We aimed at investigating the association of SVD with cerebral LAA as well as with atherosclerosis in patients with stroke likely to originate from aortic plaques. Methods: We investigated 71 consecutive patients (48 men, mean age 64.2 +/- 13 years) with ischemic stroke of undetermined cause according to the ASCO classification, who received ECG-triggered CT angiography for best available atherosclerotic plaque detection in the aorta. Results: Aortic atherosclerotic plaques were detected in 54 patients (76.1%). The presence of SVD significantly correlated with the presence of aortic plaques (p < 0.001), as well as LAA (p < 0.001) and risk factors such as arterial hypertension (p = 0.032) and diabetes mellitus (p = 0.017). Conclusions: Aortic plaques are common in patients with stroke of undetermined cause. If so, SVD and LAA are often coexisting, which demonstrates the close link of macro- and microangiopathy, at least in cases of severe risk factors of atherosclerosis. Copyright © 2012 S. Karger AG, Base

    An open source software for analysis of dynamic contrast enhanced magnetic resonance images: UMMPerfusion revisited

    Get PDF
    Background: Perfusion imaging has become an important image based tool to derive the physiological information in various applications, like tumor diagnostics and therapy, stroke, (cardio-) vascular diseases, or functional assessment of organs. However, even after 20 years of intense research in this field, perfusion imaging still remains a research tool without a broad clinical usage. One problem is the lack of standardization in technical aspects which have to be considered for successful quantitative evaluation; the second problem is a lack of tools that allow a direct integration into the diagnostic workflow in radiology. Results: Five compartment models, namely, a one compartment model (1CP), a two compartment exchange (2CXM), a two compartment uptake model (2CUM), a two compartment filtration model (2FM) and eventually the extended Toft’s model (ETM) were implemented as plugin for the DICOM workstation OsiriX. Moreover, the plugin has a clean graphical user interface and provides means for quality management during the perfusion data analysis. Based on reference test data, the implementation was validated against a reference implementation. No differences were found in the calculated parameters. Conclusion: We developed open source software to analyse DCE-MRI perfusion data. The software is designed as plugin for the DICOM Workstation OsiriX. It features a clean GUI and provides a simple workflow for data analysis while it could also be seen as a toolbox providing an implementation of several recent compartment models to be applied in research tasks. Integration into the infrastructure of a radiology department is given via OsiriX. Results can be saved automatically and reports generated automatically during data analysis ensure certain quality control

    CT angiography of the aorta is superior to transesophageal echocardiography for determining stroke subtypes in patients with cryptogenic ischemic stroke

    Get PDF
    Background: The etiology of ischemic strokes remains cryptogenic in about one third of patients, even after extensive workup in specialized centers. Atherosclerotic plaques in the aorta can cause thromboembolic events but are often overlooked. They can elude standard identification by transesophageal echocardiography (TEE), which is invasive or at best uncomfortable for many patients. CT angiography (CTA) can be used as an alternative or in addition to TEE if this technique fails to visualize every part of the aorta and in particular the aortic arch. Methods: We prospectively studied 64 patients (47 men, age 60 8 13 years) classified as having cryptogenic stroke after standard and full workup [including brain MRI and 24-hour electrocardiogram (ECG)] with ECG-triggered CTA of the aorta in search of plaques and compared the results with those of TEE. Investigators were blinded to the results of both techniques

    - LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

    Get PDF
    Background: A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. Methods: cCTA datasets were acquired on a 3rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. Results: The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. Conclusions: This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation

    Steady state vascular imaging with extracellular gadobutrol: evaluation of the additional diagnostic benefit in patients who have undergone a peripheral magnetic resonance angiography protocol

    Get PDF
    Background: To evaluate the feasibility and additional diagnostic benefit of a high-resolution steady state 3D-volume interpolated breath-hold exam (VIBE) sequence between a continuous table movement (CTM) MR angiography of the entire runoff vasculature and a time-resolved (TWIST) MRA of the calves. Methods: In this retrospective IRB approved study 224 patients (72 women, 152 men, mean age 67.29 ± 13.9) were included who had undergone a low-dose MR angiographic protocol at 3T (Siemens TimTrio) after injection of 0.1 mmol/kg gadobutrol including a CTM MRA, a time-resolved MRA of the calf station and a steady state 3D VIBE sequence prior to the time-resolved MRA. One board-certified radiologist rated the image quality of the steady state VIBE sequences on an ordinal three point scale (excellent, good, poor) and analyzed the images for additional diagnostic findings of and beyond the vascular system in comparison to the CTM MRA and the time-resolved MRA. Descriptive statistics and demographic patient data were used for further evaluation. Results: The image quality of the steady state imaging of the pelvis, upper and lower leg was excellent in up to 88%, 84% and 47%, respectively, while poor image quality was only detected in the upper (2%) and lower leg (6%). An additional diagnostic benefit was found in 44% of the patients overall. The most common relevant pathologies included inflammatory processes of the soft tissues (26%), thrombi (14%), abscesses (13%) and tumors (11%). In subgroups of patients above the age of 60, 65, 70, 75 and 80 years an additional pathology was found in 50% 33%, 44%, 65% and 58%, respectively. There was no significant difference in terms of additional findings between men and women (46% and 39%, p > 0.05) and inpatients and outpatients (42% and 45%, p > 0.05). Conclusion: Steady state imaging is also feasible with extracellular contrast agents with good image quality yielding additional diagnostic findings in up to 44% and above in patients older than 60 years of age irrespective of gender or patient status. Given the short acquisition time of 4 minutes this sequence could be added to all peripheral MRA exams

    MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial

    Get PDF
    Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: −0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CA

    A high-quality annually laminated sequence from Lake Belau, Northern Germany: Revised chronology and its implications for palynological and tephrochronological studies

    Get PDF
    The annually laminated record of Lake Belau offers an exceptional opportunity to investigate with high temporal resolution Holocene environmental change, aspects of climate history and human impact on the landscape. A new chronology based on varve counts, 14C-datings and heavy metal history has been established, covering the last 9400 years. Based on multiple varve counting on two core sequences, the easily countable laminated section spans about 7850 varve years (modelled age range c. 9430 to 1630 cal. BP). Not all of the record is of the same quality but approximately 69% of the varves sequence is classified to be of high quality and only c. 5% of low quality. The new chronology suggests dates generally c. 260 years older than previously assumed for the laminated section of the record. The implications for the vegetation and land-use history of the region as well as revised datings for pollen stratigraphical events are discussed. Tephra analysis allowed the identification of several cryptotephra layers. New dates for volcanic eruptions are presented for the Lairg B event (c. 6848 cal. BP, 2s range 6930–6713 cal. BP), the Hekla 4 event (c. 4396 cal. BP, 2s range 4417–4266 cal. BP), and Hekla 3 eruption (c. 3095 cal. BP, 2s range 3120–3068 cal. BP)

    Observer Sensitivity for Detection of Pulmonary Nodules in Ultra-Low Dose Computed Tomography Protocols Using a Third-Generation Dual-Source CT with Ultra-High Pitch&mdash;A Phantom Study

    No full text
    This study evaluates ultra-low-dose computed tomography (ULDCT) protocols concerning the detectability of pulmonary nodules. The influence of tube current settings, kernels, strength levels of third-generation iterative reconstruction algorithms, and pitch was investigated. A chest phantom with artificial spherical nodules of different densities and diameters was examined with a third-generation dual-source CT. Scanning and post-processing protocols, tube current levels, and ultra-high and non-high pitch modes were applied. Images were reconstructed with filtered back-projection (FBP) or advanced model-based iterative reconstruction (ADMIRE) algorithms. Sharp (Bl57) or medium-soft (Br36) convolution kernels were applied. The reading was performed by an experienced and an inexperienced reader. The highest observer sensitivity was found using a non-high pitch protocol at tube currents of 120 mAs and 90 mAs with the sharp kernel and iterative reconstruction level of 5. Non-high pitch protocols showed better detectability of solid nodules. Combinations with the medium-soft kernel achieved slightly higher observer sensitivity than with the sharp kernel. False positives (FP) occurred more often for subsolid nodules, at a tube current level of 120 mAs, and with the sharp kernel. A tube current level of 90 mAs combined with the highest iterative reconstruction level achieved the highest accuracy in lung nodule detection regardless of size, density, and reader experience

    From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography

    No full text
    Purpose The aim of this study was to systematically reinvestigate the first human mummy that was ever analyzed with X-ray imaging in 1896, using dual-source computed tomography (DSCT) in order to compare the earliest and latest imaging technologies, to estimate preservation, age at death, sex, anatomical variants, paleopathological findings, mummification, embalming and wrapping of the child mummy from ancient Egypt. Radiocarbon dating was used to determine the mummy’s age and to specify the child’s living period in the Egyptian chronology. Material and methods The ancient Egyptian child mummy is kept in the Senckenberg Museum of Natural History in Frankfurt am Main, Germany. An accelerator mass spectrometer (MICADAS) was used for radiocarbon dating. DSCT was performed using a 2 × 64 slice dual-source CT system (Siemens Healthineers, Forchheim, Germany). A thorough visual examination of the mummy, a systematic radiological evaluation of the DICOM datasets, and established methods in physical anthropology were applied to assess the bio-anthropological data and the post mortem treatment of the body. Results: Radiocarbon dating yielded a calibrated age between 378 and 235 cal BC (95.4% confidence interval), corresponding with the beginning of the Ptolemaic period. The mummy was a male who was four to five years old at the time of death. Remnants of the brain and inner organs were preserved by the embalmers, which is regularly observed in ancient Egyptian child mummies. Skin tissue, inner organs, tendons and/or musculature, cartilage, nerves and vasculature could be identified on the DSCT dataset. The dental health of the child was excellent. Anatomical variants and pathological defects included a congenital Pectus excavatum deformity, hepatomegaly, Harris lines, and longitudinal clefts in the ventral cortices of both femora. Conclusion: Our results highlight the enormous progress achieved form earliest to latest imaging technology for advanced mummy research using the first human mummy investigated with X-ray. With the application of DSCT, detailed knowledge regarding age at death, sex, diseases, death, and mummification of a child from Ptolemaic Egypt are revealed while considering the temporary rites of body treatment and burial for children
    corecore