84 research outputs found

    Cryoballoon ablation for atrial fibrillation: Effects on neuromodulation

    Get PDF
    Pulmonary vein isolation (PVI) represents the mainstay of atrial fibrillation (AF) ablation, and PVI with cryoballoon catheter (CB) ablation (CB-A) has proven to be as effective and safe as radiofrequency ablation (RF-A). Although AF is initiated by triggers arising from the pulmonary veins (PV) and non-PV foci, the intrinsic cardiac nervous system (ICNS) plays a significant role in the induction and maintenance of AF. The ICNS is an epicardial neural system composed of ganglionated plexi (GPs) and a complex network of interconnecting neurons. In the left atrium, the major GPs are located in proximity to the PV-left atrial junction. Vagal reactions have been described as markers of autonomic modulation during PVI with both RF-A and CB-A. The occurrence of neuromodulation during PVI with CB-A may be explained by both the anatomical relationship between the GPs and the PVs and the characteristics of the CB. Due to the CB/PV size mismatch, the CB creates a wide ablation area that extends from the PV ostium toward the antrum, possibly including the GPs. Although targeted GPs ablation, as a supplemental strategy to PVI, has been associated with a better AF outcome in patients undergoing RF-A, the additional clinical benefit of neuromodulation during PVI with CB-A remains a matter of debate. In this review, we provide an overview of the anatomy of the ICNS, the relationship between the ICNS and AF pathophysiology, and the current evidence on the clinical relevance of neuromodulation during PVI with CB-A

    Risk factors for gram-negative bacterial infection of cardiovascular implantable electronic devices: Multicentre observational study (CarDINe Study)

    Get PDF
    Background: Infections of cardiovascular implantable electronic devices (CIED) are mainly due to Gram-positive bacteria (GPB). Data about Gram-negative bacteria CIED (GNB-CIED) infections are limited. This study aimed to investigate risk factors, clinical and diagnostic characteristics, and outcome of patients with GNB-CIED. Methods: A multicentre, international, retrospective, case-control-control study was performed on patients undergoing CIED implantation from 2015 to 2019 in 17 centres across Europe. For each patient diagnosed with GNB-CIED, one matching control with GPB-CIED infection and two matching controls without infection were selected. Results: A total of 236 patients were enrolled: 59 with GNB-CIED infection, 59 with GPB-CIED infection and 118 without infection. No between-group differences were found regarding clinical presentation, diagnostic and therapeutic management. A trend toward a higher rate of fluorodeoxyglucose positron emission computed tomography (FDG PET/CT) positivity was observed among patients with GNB than in those with GPB-CIED infection (85.7% vs. 66.7%; P = 0.208). Risk factors for GNB-CIED infection were Charlson Comorbidity Index Score (relative risk reduction, RRR = 1.211; P = 0.011), obesity (RRR = 5.122; P = 0.008), ventricular-pacing ventricular-sensing inhibited-response pacemaker implantation (RRR = 3.027; P = 0.006) and right subclavian vein site of implantation (RRR = 5.014; P = 0.004). At 180-day survival analysis, GNB-CIED infection was associated with increased mortality risk (HR = 1.842; P = 0.067). Conclusions: Obesity, high number of comorbidities and right subclavian vein implantation site were associated with increased risk of GNB-CIED infection. A prompt therapeutic intervention that may be guided using FDG PET/CT is suggested in patients with GNB-CIED infection, considering the poorer outcome observed in this group

    REducing INFectiOns thRough Cardiac device Envelope: insight from real world data. The REINFORCE Project

    Get PDF
    Background: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. Aims: to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population. Methods: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Results: Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs 0.8%, p = 0.007). The 5-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, p = 0.010). Conclusions: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection

    Prevention of long‐lasting atrial fibrillation through antitachycardia pacing in DDDR pacemakers

    Get PDF
    Objective The MINERVA trial showed that in pacemaker patients with atrial fibrillation (AF) history, DDDRP pacing combining three algorithms - (a) atrial antitachycardia pacing with Reactive ATP enabled, (b) atrial preventive pacing and (c) managed ventricular pacing (MVP)-may effectively delay progression to persistent/permanent AF compared with standard DDDR pacing. We performed a comparative non-randomised evaluation to evaluate if Reactive ATP can be the main driver of persistent/permanent AF reduction independently on preventive pacing. Methods Thirty-one centres included consecutive dual-chamber pacemaker patients with AF history. Reactive ATP was programmed in all patients while preventive atrial pacing was not enabled. These patients were compared with the three groups of MINERVA randomised trial (Control DDDR, MVP, and DDDRP). The main endpoint was the incidence of AF longer than 7 consecutive days. Results A total of 146 patients (73 years old, 54% male) were included and followed for a median observation period of 31 months. The 2-year incidence of AF > 7 days was 12% in the Reactive ATP group, very similar to that found in the DDDRP arm of the MINERVA trial (13.8%, P = .732) and significantly lower than AF incidence found in the MINERVA Control DDDR arm (25.8%, P = .012) and in the MINERVA MVP arm (25.9%, P = .025). Conclusions In a real-world population of dual-chamber pacemaker patients with AF history, the use of Reactive ATP is associated with a low incidence of persistent AF, highlighting that the positive results of the MINERVA trial were related to the effectiveness of Reactive ATP rather than to preventive pacing

    Initial rhythm control with cryoballoon ablation vs drug therapy: Impact on quality of life and symptoms

    Get PDF
    Background Cryoballoon ablation (CBA) as a first-line rhythm control strategy is superior to antiarrhythmic drugs (AADs) for preventing atrial fibrillation (AF) recurrence; the impact of first-line CBA on quality of life (QoL) and symptoms has not been well characterized. Methods Patients aged 18 to 75 with symptomatic paroxysmal AF naïve to rhythm control therapy were randomized (1:1) to CBA (Arctic Front Advance, Medtronic) or AAD (Class I or III). Symptoms and QoL were assessed at baseline, 1, 3, 6, 9, and 12 months using the EHRA classification and Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and SF-36v2 questionnaires. Symptomatic palpitations were evaluated via patient diary. Results Overall, 107 patients were randomized to CBA and 111 to AAD; crossovers occurred in 9%. Larger improvements in the AFEQT summary, subscale and treatment satisfaction scores were observed at 12 months with CBA vs AAD (all P <0.05). At 12 months, the mean adjusted difference in the AFEQT summary score was 9.9 points higher in the CBA group (95% CI: 5.5 –14.2, P <0.001). Clinically important improvements in the SF-36 physical and mental component scores were observed at 12 months in both groups, with no significant between group differences at this timepoint. In the CBA vs AAD group, larger improvements in EHRA class were observed at 6, 9 and 12 months (P <0.05) and the incidence rate of symptomatic palpitations was lower (4.6 vs 15.2 days/year post-blanking; IRR: 0.30, P <0.001). Conclusions In patients with symptomatic AF, first-line CBA was superior to AAD for improving AF-specific QoL and symptoms.publishedVersio

    Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry

    Get PDF
    The incidence of infections associated with cardiac implantable electronic devices (CIEDs) and patient outcomes are not fully known. To provide a contemporary assessment of the risk of CIEDs infection and associated clinical outcomes. In Italy, 18 centres enrolled all consecutive patients undergoing a CIED procedure and entered a 12-months follow-up. CIED infections, as well as a composite clinical event of infection or all-cause death were recorded. A total of 2675 patients (64.3% male, age 78 (70-84)) were enrolled. During follow up 28 (1.1%) CIED infections and 132 (5%) deaths, with 152 (5.7%) composite clinical events were observed. At a multivariate analysis, the type of procedure (revision/upgrading/reimplantation) (OR: 4.08, 95% CI: 1.38-12.08) and diabetes (OR: 2.22, 95% CI: 1.02-4.84) were found as main clinical factors associated to CIED infection. Both the PADIT score and the RI-AIAC Infection score were significantly associated with CIED infections, with the RI-AIAC infection score showing the strongest association (OR: 2.38, 95% CI: 1.60-3.55 for each point), with a c-index = 0.64 (0.52-0.75), p = 0.015. Regarding the occurrence of composite clinical events, the Kolek score, the Shariff score and the RI-AIAC Event score all predicted the outcome, with an AUC for the RI-AIAC Event score equal to 0.67 (0.63-0.71) p < 0.001. In this Italian nationwide cohort of patients, while the incidence of CIED infections was substantially low, the rate of the composite clinical outcome of infection or all-cause death was quite high and associated with several clinical factors depicting a more impaired clinical status
    corecore