50 research outputs found
Comparative Study on Thresholding
Criterion based thresholding algorithms are simple and effective for two-level thresholding. However, if a multilevel thresholding is needed, the computational complexity will exponentially increase and the performance may become unreliable. In this approach, a novel and more effective method is used for multilevel thresholding by taking hierarchical cluster organization into account. Developing a dendogram of gray levels in the histogram of an image, based on the similarity measure which involves the inter-class variance of the clusters to be merged and the intra-class variance of the new merged cluster . The bottom-up generation of clusters employing a dendogram by the proposed method yields good separation of the clusters and obtains a robust estimate of the threshold. Such cluster organization will yield a clear separation between object and background even for the case of nearly unimodal or multimodal histogram. Since the hierarchical clustering method performs an iterative merging operation, it is extended to multilevel thresholding problem by eliminating grouping of clusters when the pixel values are obtained from the expected numbers of clusters. This paper gives a comparison on Otsu’s & Kwon’s criterion with hierarchical based multi-level thresholding
Study of Decays
We report on a study of decays using
29.1 fb of annihilation data recorded at the
resonance with the Belle detector at the KEKB storage ring. Making no
assumptions about the intermediate mechanism, the branching fractions for
and are
determined to be and respectively. An analysis of candidates yields to the first observation of the color-suppressed
hadronic decay with the branching fraction . We measure the ratio of branching fractions
= 1.6 0.8.Comment: 13 pages, LaTex, 4 figures, submitted to Phys. Lett.
Measurement of the Branching Fraction for B->eta' K and Search for B->eta'pi+
We report measurements for two-body charmless B decays with an eta' meson in
the final state. Using 11.1X10^6 BBbar pairs collected with the Belle detector,
we find BF(B^+ ->eta'K^+)=(79^+12_-11 +-9)x10^-6 and BF(B^0 ->
eta'K^0)=(55^+19_-16 +-8)x10^-6, where the first and second errors are
statistical and systematic, respectively. No signal is observed in the mode B^+
-> eta' pi^+, and we set a 90% confidence level upper limit of BF(B^+->
eta'pi^+) eta'K^+- decays is
investigated and a limit at 90% confidence level of -0.20<Acp<0.32 is obtained.Comment: Submitted to Physics Letters
Observation of Cabibbo-suppressed and W-exchange Lambda_c^+ baryon decays
We present measurements of the Cabibbo-suppressed decays Lambda_c^+ -->
Lambda0 K+ and Lambda_c^+ --> Sigma0 K+ (both first observations), Lambda_c^+
--> Sigma+ K+ pi- (seen with large statistics for the first time), Lambda_c^+
--> p K+ K- and Lambda_c^+ --> p phi (measured with improved accuracy).
Improved branching ratio measurements for the decays Lambda_c^+ --> Sigma+ K+
K- and Lambda_c^+ --> Sigma+ phi, which are attributed to W-exchange diagrams,
are shown. We also present the first evidence for Lambda_c^+ --> Xi(1690)^0 K+
and set an upper limit on the non-resonant decay Lambda_c^+ --> Sigma+ K+ K-.
This analysis was performed using 32.6 fb^{-1} of data collected by the Belle
detector at the asymmetric e+ e- collider KEKB.Comment: Submitted to Phys. Lett. B. v2: A small correction to the Authorlist
was made. An earlier version of this analysis was released as
BELLE-CONF-0130, hep-ex/010800
Search for the Electric Dipole Moment of the tau Lepton
We have searched for a CP violation signature arising from an electric dipole
moment (d_tau) of the tau lepton in the e+e- -> tau+tau- reaction. Using an
optimal observable method and 29.5 fb^{-1} of data collected with the Belle
detector at the KEKB collider at sqrt{s} = 10.58 GeV, we find Re(d_tau) = (1.15
+- 1.70) x 10^{-17} ecm and Im(d_tau) = (-0.83 +- 0.86) x 10^{-17} ecm and set
the 95% confidence level limits -2.2 < Re(d_tau) < 4.5 (10^{-17}ecm) and -2.5 <
Im(d_tau) < 0.8 (10^{-17}ecm).Comment: 15 pages, LaTeX, 21 figures, submitted to Phys. Lett.
Measurement of the inclusive semileptonic branching fraction of B mesons and |Vcb|
We present a measurement of the electron spectrum from inclusive semileptonic
{\it B} decay, using 5.1 fb of data collected with the
Belle detector. A high-momentum lepton tag was used to separate the
semileptonic {\it B} decay electrons from secondary decay electrons. We
obtained the branching fraction, , with minimal model dependence.
From this measurement, we derive a value for the Cabibbo-Kobayashi-Maskawa
matrix element .Comment: 16 pages, 3 figures, 3 table
Determination of |Vcb| using the semileptonic decay \bar{B}^0 --> D^{*+}e^-\bar{\nu}
We present a measurement of the Cabibbo-Kobayashi-Maskawa (CKM) matrix
element |Vcb| using a 10.2 fb^{-1} data sample recorded at the \Upsilon(4S)
resonance with the Belle detector at the KEKB asymmetric e^+e^- storage ring.
By extrapolating the differential decay width of the \bar{B}^0 -->
D^{*+}e^-\bar{\nu} decay to the kinematic limit at which the D^{*+} is at rest
with respect to the \bar{B}^0, we extract the product of |Vcb| with the
normalization of the decay form factor F(1), |Vcb |F(1)=
(3.54+/-0.19+/-0.18)x10^{-2}, where the first error is statistical and the
second is systematic. A value of |Vcb| = (3.88+/-0.21+/-0.20+/-0.19)x10^{-2} is
obtained using a theoretical calculation of F(1), where the third error is due
to the theoretical uncertainty in the value of F(1). The branching fraction
B(\bar{B}^0 --> D^{*+}e^-\bar{\nu}) is measured to be
(4.59+/-0.23+/-0.40)x10^{-2}.Comment: 20 pages, 6 figures, elsart.cls, submitted to PL
A Measurement of the Branching Fraction for the Inclusive B --> X(s) gamma Decays with the Belle Detector
We have measured the branching fraction of the inclusive radiative B meson
decay B --> X(s) gamma to be Br(B->X(s)gamma)=(3.36 +/- 0.53(stat) +/-
0.42(sys) +0.50-0.54(th)) x 10^{-4}.
The result is based on a sample of 6.07 x 10^6 BBbar events collected at the
Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric e^+e^-
storage ring.Comment: 14 pages, 6 Postsript figures, uses elsart.cl
Measurement of \chi_{c2} Production in Two-Photon Collisions
The production of the \chi_{c2} charmonium state in two-photon collisions has
been measured with the Belle detector at the KEKB e^+e^- collider. A clear
signal for \chi_{c2} --> \gamma J/\psi, J/\psi --> l^+l^- is observed in a
32.6fb^{-1} data sample accumulated at center-of-mass energies near 10.6GeV,
and the product of its two-photon decay width and branching fraction is
determined to be \Gamma_{\gamma\gamma}(\chi_{c2})B(\chi_{c2} --> \gamma J/\psi)
B(J/\psi --> l^+l^-)= 13.5 +/- 1.3(stat.) +/- 1.1(syst.)eV.Comment: 16 pages, 5 figures, to be submitted to Phys. Lett.
Provider Attitudes and Practice Patterns for Direct-Acting Antiviral Therapy for Patients With Hepatocellular Carcinoma
Background & Aims: Direct-acting antivirals (DAAs) are effective against hepatitis C virus and sustained virologic response is associated with reduced incidence of hepatocellular carcinoma (HCC). However, there is controversy over the use of DAAs in patients with active or treated HCC and uncertainty about optimal management of these patients. We aimed to characterize attitudes and practice patterns of hepatology practitioners in the United States regarding the use of DAAs in patients with HCC. Methods: We conducted a survey of hepatology providers at 47 tertiary care centers in 25 states. Surveys were sent to 476 providers and we received 279 responses (58.6%). Results: Provider beliefs about risk of HCC recurrence after DAA therapy varied: 48% responded that DAAs reduce risk, 36% responded that DAAs do not change risk, and 16% responded that DAAs increase risk of HCC recurrence. However, most providers believed DAAs to be beneficial to and reduce mortality of patients with complete response to HCC treatment. Accordingly, nearly all providers (94.9%) reported recommending DAA therapy to patients with early-stage HCC who received curative treatment. However, fewer providers recommended DAA therapy for patients with intermediate (72.9%) or advanced (57.5%) HCC undergoing palliative therapies. Timing of DAA initiation varied among providers based on HCC treatment modality: 49.1% of providers reported they would initiate DAA therapy within 3 months of surgical resection whereas 45.9% and 5.0% would delay DAA initiation for 3–12 months and >1 year post-surgery, respectively. For patients undergoing transarterial chemoembolization (TACE), 42.0% of providers would provide DAAs within 3 months of the procedure, 46.7% would delay DAAs until 3–12 months afterward, and 11.3% would delay DAAs more than 1 year after TACE. Conclusions: Based on a survey sent to hepatology providers, there is variation in provider attitudes and practice patterns regarding use and timing of DAAs for patients with HCC. Further studies are needed to characterize the risks and benefits of DAA therapy in this patient population