51 research outputs found

    Versatile Coordination of Cyclopentadienyl-Arene Ligands and Its Role in Titanium-Catalyzed Ethylene Trimerization

    Get PDF
    Cationic titanium(IV) complexes with ansa-(η5-cyclopentadienyl,η6-arene) ligands were synthesized and characterized by X-ray crystallography. The strength of the metal-arene interaction in these systems was studied by variable-temperature NMR spectroscopy. Complexes with a C1 bridge between the cyclopentadienyl and arene moieties feature hemilabile coordination behavior of the ligand and consequently are active ethylene trimerization catalysts. Reaction of the titanium(IV) dimethyl cations with CO results in conversion to the analogous cationic titanium(II) dicarbonyl species. Metal-to-ligand backdonation in these formally low-valent complexes gives rise to a strongly bonded, partially reduced arene moiety. In contrast to the η6-arene coordination mode observed for titanium, the more electron-rich vanadium(V) cations [cyclopentadienyl-arene]V(NiPr2)(NC6H4-4-Me)+ feature η1-arene binding, as determined by a crystallographic study. The three different metal-arene coordination modes that we experimentally observed model intermediates in the cycle for titanium-catalyzed ethylene trimerization. The nature of the metal-arene interaction in these systems was studied by DFT calculations.

    Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report

    Get PDF
    With the presented case we strive to introduce combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) as new diagnostic imaging modality and illustrate the possible clinical value in patients after ACL reconstruction. We report the case of a painful knee due to a foreign body reaction and delayed degradation of the biodegradable interference screws after ACL reconstruction. The MRI showed an intact ACL graft, a possible tibial cyclops lesion and a patella infera. There was no increased fluid collection within the bone tunnels. The 99mTc-HDP-SPECT/CT clearly identified a highly increased tracer uptake around and within the tibial and femoral tunnels and the patellofemoral joint. On 3D-CT out of the SPECT/CT data the femoral graft attachment was shallow (50% along the Blumensaat's line) and high in the notch. At revision arthroscopy a diffuse hypertrophy of the synovium, scarring of the Hoffa fat pad and a cyclops lesion of the former ACL graft was found. The interference screws were partially degraded and under palpation and pressure a grey fluid-like substance drained into the joint. The interference screws and the ACL graft were removed and an arthrolysis performed
    corecore