33 research outputs found

    Evaluation of Bedside Tests of Attention and Arousal Assessing Delirium in Parkinson's Disease, Dementia, and Older Adults

    Get PDF
    BACKGROUND: Delirium is a serious acute neuropsychiatric condition associated with altered attention and arousal. OBJECTIVE: To evaluate simple bedside tests for attention and arousal to detect delirium in those with and without Parkinson's disease (PD) and dementia. METHODS: Participants from two prospective delirium studies were pooled comprising 30 with PD without cognitive impairment, 24 with Lewy body cognitive impairment (PD dementia or dementia with Lewy bodies), 16 with another dementia and 179 PD and dementia-free older adults. Participants completed standardised delirium assessments including tests of attention: digit span, Memorial Delirium Assessment Scale (MDAS) attention and months of the year backwards; and arousal: Glasgow Coma Scale (GSC), Observational Scale of Level of Arousal (OSLA), Modified Richmond Agitation Scale and MDAS consciousness. Delirium was diagnosed using the DSM-5 criteria. RESULTS: On their first admission, 21.7%participants had prevalent delirium. Arousal measures accurately detected delirium in all participants (p <  0.01 for all), but only selected attention measures detected delirium in PD and dementia. In PD and dementia-free older adults, impaired digit span and OSLA were the optimal tests to detect delirium (area under the curve [AUC] = 0.838, p <  0.001) while in PD and dementia the optimal tests were MDAS attention and GCS LB. CONCLUSION: Simple bedside tests of attention and arousal at a single visit could accurately detect delirium in PD, dementia and PD and dementia-free older adults; however, the optimal tests differed between groups. Combined attention and arousal scores increased accuracy, which could have clinical utility to aid the identification of delirium neurodegenerative disorders

    Assessment of autonomic symptoms may assist with early identification of mild cognitive impairment with Lewy bodies

    Get PDF
    Funder: GE Healthcare; Id: http://dx.doi.org/10.13039/100006775Funder: Alzheimer's Research UK; Id: http://dx.doi.org/10.13039/501100002283Funder: NIHR Newcastle Biomedical Research Centre; Id: http://dx.doi.org/10.13039/501100012295Abstract: Objectives: Autonomic symptoms are a common feature of the synucleinopathies, and may be a distinguishing feature of prodromal Lewy body disease. We aimed to assess whether the cognitive prodrome of dementia with Lewy bodies, mild cognitive impairment (MCI) with Lewy bodies (MCI‐LB), would have more severe reported autonomic symptoms than cognitively healthy older adults, with MCI due to Alzheimer's disease (MCI‐AD) also included for comparison. We also aimed to assess the utility of an autonomic symptom scale in differentiating MCI‐LB from MCI‐AD. Methods: Ninety‐three individuals with MCI and 33 healthy controls were assessed with the Composite Autonomic Symptom Score 31‐item scale (COMPASS). Mild cognitive impairment patients also underwent detailed clinical assessment and differential classification of MCI‐AD or MCI‐LB according to current consensus criteria. Differences in overall COMPASS score and individual symptom sub‐scales were assessed, controlling for age. Results: Age‐adjusted severity of overall autonomic symptomatology was greater in MCI‐LB (Ratio = 2.01, 95% CI: 1.37–2.96), with higher orthostatic intolerance and urinary symptom severity than controls, and greater risk of gastrointestinal and secretomotor symptoms. MCI‐AD did not have significantly higher autonomic symptom severity than controls overall. A cut‐off of 4/5 on the COMPASS was sensitive to MCI‐LB (92%) but not specific to this (42% specificity vs. MCI‐AD and 52% vs. healthy controls). Conclusions: Mild cognitive impairment with Lewy bodies had greater autonomic symptom severity than normal ageing and MCI‐AD, but such autonomic symptoms are not a specific finding. The COMPASS‐31 may therefore have value as a sensitive screening test for early‐stage Lewy body disease

    Development of a UK core dataset for geriatric medicine research: : a position statement and results from a Delphi consensus process

    Get PDF
    Funding AS and MW are funded by the Newcastle National Institute for Health (NIHR) Biomedical Research Centre, which also funded the initial meeting of academic clinicians in geriatric medicine during the Delphi process. The views expressed in this article are those of the authors and not necessarily those of the NIHR, the NHS, or the Department of Health. Acknowledgements The authors acknowledge the contributions of members of the UK Geriatric Medicine Core Dataset Extended Working Group.Peer reviewedPublisher PD

    A multi-sensor wearable system for the assessment of diseased gait in real-world conditions

    Get PDF
    Introduction: Accurately assessing people’s gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors).Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson’s disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity.Results and discussion: Excellent absolute agreement (ICC &gt;0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≀0.61 steps/min, stride length ≀0.02 m, walking speed ≀0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72–4.87 steps/min, stride length 0.04–0.06 m, walking speed 0.03–0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions

    Design and validation of a multi-task, multi-context protocol for real-world gait simulation

    Get PDF
    Background: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. Methods: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants’ strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson’s disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. Results: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. Conclusions: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. Trial registration: ISRCTN—12246987

    Technical validation of real-world monitoring of gait: a multicentric observational study

    Get PDF
    Introduction: Existing mobility endpoints based on functional performance, physical assessments and patient self-reporting are often affected by lack of sensitivity, limiting their utility in clinical practice. Wearable devices including inertial measurement units (IMUs) can overcome these limitations by quantifying digital mobility outcomes (DMOs) both during supervised structured assessments and in real-world conditions. The validity of IMU-based methods in the real- world, however, is still limited in patient populations. Rigorous validation procedures should cover the device metrological verification, the validation of the algorithms for the DMOs computation specifically for the population of interest and in daily life situations, and the users’ perspective on the device. Methods and analysis: This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs. After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson’s disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users’ perspective on the deployed technology and relevance of the mobility assessment. Ethics and dissemination: The study has been granted ethics approval by the centre’s committees (London—Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of TĂŒbingen and of the University of Kiel). Data and algorithms will be made publicly available

    Clinical forum: how effectively are we managing pain in cattle?

    No full text
    Cattle practitioners are responsible for the health and welfare of their patients, including minimising pain and discomfort. Surveys of practitioners have shown wide variation in the recognition of painful processes in cattle, and in the use of analgesic agents. Here we investigate assessment of pain in cattle, analgesic options available, and some of the barriers to analgesic use. In this clinical forum the panel members consider what the gold standards in pain relief are, and what is being done in the field. </jats:p

    Evaluating genetic ancestry and self-reported ethnicity in the context of carrier screening

    No full text
    Abstract Background Current professional society guidelines recommend genetic carrier screening be offered on the basis of ethnicity, or when using expanded carrier screening panels, they recommend to compute residual risk based on ethnicity. We investigated the reliability of self-reported ethnicity in 9138 subjects referred to carrier screening. Self-reported ethnicity gathered from test requisition forms and during post-test genetic counseling, and genetic ancestry predicted by a statistical model, were compared for concordance. Results We identified several discrepancies between the two sources of self-reported ethnicity and genetic ancestry. Only 30.3% of individuals who indicated Mediterranean ancestry during consultation self-reported this on requisition forms. Additionally, the proportion of individuals who reported Southeast Asian but were estimated to have a different genetic ancestry was found to depend on the source of self-report. Finally, individuals who reported Latin American demonstrated a high degree of ancestral admixture. As a result, carrier rates and residual risks provided for patient decision-making are impacted if using self-reported ethnicity. Conclusion Our analysis highlights the unreliability of ethnicity classification based on patient self-reports. We recommend the routine use of pan-ethnic carrier screening panels in reproductive medicine. Furthermore, the use of an ancestry model would allow better estimation of carrier rates and residual risks
    corecore