1,162 research outputs found

    The GRAAL high resolution BGO calorimeter and its energy calibration and monitoring system

    Get PDF
    We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy calibration accuracy and stability reached is a small fraction of the intrinsic detector resolution.Comment: 19 pages, 14 figures, submitted to Nuclear Instruments and Method

    Eta photoproduction off the neutron at GRAAL: Evidence for a resonant structure at W=1.67 GeV

    Full text link
    New (preliminary) data on eta photoproduction off the neutron are presented. These data reveal a resonant structure at W=1.67 GeV.Comment: 8 pages, 4 figures. Published in Proceedings of Workshop on the Physics of Excited Nucleons NSTAR2004, Grenoble, France, March 24 - 27, pg.19

    Eta photoproduction off the neutron at GRAAL

    Full text link
    The gamma n -> eta n quasi-free cross section reveals a resonant structure at W ~ 1.675 GeV. This structure may be a manifestation of a baryon resonance. A priori its properties, the possibly narrow width and the strong photocoupling to the neutron, look surprising. This structure may also signal the existence of a narrow state.Comment: To appear in Proceedings of Workshop on the Physics of Excited Nucleons NSTAR2005, 12 - 15 October 2005, Tallahassee, Florida, US

    A new limit on the light speed isotropy from the GRAAL experiment at the ESRF

    Full text link
    When the electrons stored in the ring of the European Synchrotron Radiation Facility (ESRF, Grenoble) scatter on a laser beam (Compton scattering in flight) the lower energy of the scattered electron spectra, the Compton Edge (CE), is given by the two body photon-electron relativistic kinematics and depends on the velocity of light. A precision measurement of the position of this CE as a function of the daily variations of the direction of the electron beam in an absolute reference frame provides a one-way test of Relativistic Kinematics and the isotropy of the velocity of light. The results of GRAAL-ESRF measurements improve the previously existing one-way limits, thus showing the efficiency of this method and the interest of further studies in this direction.Comment: Proceed. MG12 meeting, Paris, July, 200

    Limits on light-speed anisotropies from Compton scattering of high-energy electrons

    Full text link
    The possibility of anisotropies in the speed of light relative to the limiting speed of electrons is considered. The absence of sidereal variations in the energy of Compton-edge photons at the ESRF's GRAAL facility constrains such anisotropies representing the first non-threshold collision-kinematics study of Lorentz violation. When interpreted within the minimal Standard-Model Extension, this result yields the two-sided limit of 1.6 x 10^{-14} at 95% confidence level on a combination of the parity-violating photon and electron coefficients kappa_{o+} and c. This new constraint provides an improvement over previous bounds by one order of magnitude.Comment: 4 pages, 4 figure

    Planck-LFI radiometers tuning

    Get PDF
    "This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning philosophy, the activities and the obtained results, highlighting developments and changes occurred during test campaigns. The paper concludes with an overview of tuning performed during the satellite cryogenic test campaign (Summer 2008) and of the plans for the just started in-flight calibration.Comment: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at http://dx.doi.org/10.1088/1748-0221/4/12/T12013

    Eta photoproduction on the neutron at GRAAL: Measurement of the differential cross section

    Full text link
    In this contribution, we will present our first preliminary measurement of the differential cross section for the reaction gamma+n->eta+n. Comparison of the reactions gamma+p->eta+p for free and bound proton (D2 target) will also be discussed.Comment: 6 pages, 4 figures, Proceedings of the 10th International Symposium on Meson-Nucleon Physics and the Structure of the Nucleon, August 29-September 4 2004, Beijing, Chin

    Lowering the Light Speed Isotropy Limit: European Synchrotron Radiation Facility Measurements

    Full text link
    The measurement of the Compton edge of the scattered electrons in GRAAL facility in European Synchrotron Radiation Facility (ESRF) in Grenoble with respect to the Cosmic Microwave Background dipole reveals up to 10 sigma variations larger than the statistical errors. We now show that the variations are not due to the frequency variations of the accelerator. The nature of Compton edge variations remains unclear, thus outlining the imperative of dedicated studies of light speed anisotropy
    corecore