2,105 research outputs found
Product shape change by internal stresses
The design of a product component may require complex processing steps such as metal forming followed by a thermal treatment. The thermal treatment may improve the functional performance of the material itself, but may result in rather unwanted changes in the shape of the product. Here it is shown that Finite Element modeling of the various processes can assist in the design of a robust and accurate production process. The modeling approach presented allows a coupling between various complex material models, in such a way that full cold forming and thermal treatment processes are calculated. This coupling of material models is key for the design and concerns the novelty of the proposed approach. Cold forming by deep drawing is calculated whereby planar anisotropy is implemented. The thermal hardening treatment consists of three contributions: creep, thermal expansion and phase transformation. All models are based on experimental data, acquired from tensile and dilatometer tests, and are implemented into the material model either directly or by a simple fit. It is shown that the effects of a complete forming and heat treatment of a cup could be successfully calculated. The predicted cup shape change was compared to experiments, and shows excellent agreement.This research was carried out under the project number T63.3.12480 in the framework of the research program of the Materials innovation institute M2i, Delft, the Netherlands; and has been part of Press Perfect project, RFSR-CT-2012-00021 funded by the Research Fund for Coal & Steel.Peer Reviewe
Optically-pumped dilute nitride spin-VCSEL
We report the first room temperature optical spin-injection of a dilute nitride 1300 nm vertical-cavity surface-emitting laser (VCSEL) under continuous-wave optical pumping. We also present a novel experimental protocol for the investigation of optical spin-injection with a fiber setup. The experimental results indicate that the VCSEL polarization can be controlled by the pump polarization, and the measured behavior is in excellent agreement with theoretical predictions using the spin flip model. The ability to control the polarization of a long-wavelength VCSEL at room temperature emitting at the wavelength of 1.3 Όm opens up a new exciting research avenue for novel uses in disparate fields of technology ranging from spintronics to optical telecommunication networks. © 2012 Optical Society of America
A Kato type Theorem for the inviscid limit of the Navier-Stokes equations with a moving rigid body
The issue of the inviscid limit for the incompressible Navier-Stokes
equations when a no-slip condition is prescribed on the boundary is a famous
open problem. A result by Tosio Kato says that convergence to the Euler
equations holds true in the energy space if and only if the energy dissipation
rate of the viscous flow in a boundary layer of width proportional to the
viscosity vanishes. Of course, if one considers the motion of a solid body in
an incompressible fluid, with a no-slip condition at the interface, the issue
of the inviscid limit is as least as difficult. However it is not clear if the
additional difficulties linked to the body's dynamic make this issue more
difficult or not. In this paper we consider the motion of a rigid body in an
incompressible fluid occupying the complementary set in the space and we prove
that a Kato type condition implies the convergence of the fluid velocity and of
the body velocity as well, what seems to indicate that an answer in the case of
a fixed boundary could also bring an answer to the case where there is a moving
body in the fluid
Mechano-Optical Analysis of Single Cells with Transparent Microcapillary Resonators
The study of biophysical properties of single cells is becoming increasingly relevant in cell biology and pathology. The measurement and tracking of magnitudes such as cell stiffness, morphology, and mass or refractive index have brought otherwise inaccessible knowledge about cell physiology, as well as innovative methods for high-throughput label-free cell classification. In this work, we present hollow resonator devices based on suspended glass microcapillaries for the simultaneous measurement of single-cell buoyant mass and reflectivity with a throughput of 300 cells/minute. In the experimental methodology presented here, both magnitudes are extracted from the devices' response to a single probe, a focused laser beam that enables simultaneous readout of changes in resonance frequency and reflected optical power of the devices as cells flow within them. Through its application to MCF-7 human breast adenocarcinoma cells and MCF-10A nontumorigenic cells, we demonstrate that this mechano-optical technique can successfully discriminate pathological from healthy cells of the same tissue type
Existence of global strong solutions to a beam-fluid interaction system
We study an unsteady non linear fluid-structure interaction problem which is
a simplified model to describe blood flow through viscoleastic arteries. We
consider a Newtonian incompressible two-dimensional flow described by the
Navier-Stokes equations set in an unknown domain depending on the displacement
of a structure, which itself satisfies a linear viscoelastic beam equation. The
fluid and the structure are fully coupled via interface conditions prescribing
the continuity of the velocities at the fluid-structure interface and the
action-reaction principle. We prove that strong solutions to this problem are
global-in-time. We obtain in particular that contact between the viscoleastic
wall and the bottom of the fluid cavity does not occur in finite time. To our
knowledge, this is the first occurrence of a no-contact result, but also of
existence of strong solutions globally in time, in the frame of interactions
between a viscous fluid and a deformable structure
Optimization-Based wearable tactile rendering
Novel wearable tactile interfaces offer the possibility to simulate tactile interactions with virtual environments directly on our skin. But, unlike kinesthetic interfaces, for which haptic rendering is a well explored problem, they pose new questions about the formulation of the rendering problem. In this work, we propose a formulation of tactile rendering as an optimization problem, which is general for a large family of tactile interfaces. Based on an accurate simulation of contact between a finger model and the virtual environment, we pose tactile rendering as the optimization of the device configuration, such that the contact surface between the device and the actual finger matches as close as possible the contact surface in the virtual environment. We describe the optimization formulation in general terms, and we also demonstrate its implementation on a thimble-like wearable device. We validate the tactile rendering formulation by analyzing its force error, and we show that it outperforms other approaches
- âŠ